FT-50 Fill Level Inspector Service Manual

Rejector Type

Selects the rejector model that is controlled by the FT-50.

PLC Series Alarms

Activates or deactivates the PLC Series Alarms Function. If set to
PRESENT, the following options are activated:
• PLC Output Pulse Width
• Alarm Series Underfills
• Alarm Series Overfills
• Alarm Series Missing Lid
• Alarm Series Bulged End
• Alarm Series Down Can
• Alarm Series Dia. Missing Lid
• Alarm Series Any Other Inspections.
• PLC Assignments
See Chapter 9: Using a PLC With Your FT-50 for more information.

Serial Interface

Activates or deactivates the Serial Interface function. For more
information refer to the Serial Communication Manual.

External Trigger Logic

External Trigger Logic allows you to configure an external trigger,
such a s a manual switch, to perform either an External Reject or a
Remote Clear of Error.
External Reject: If the input TB1-20 is connected to ground (TB1-21)
the next container to pass the trigger will be rejected.
Remote Clear of Error: If the input TB1-20 is connected to ground
(TB1-21) the diagnostic error will be cleared.
Industrial Dynamics Company, Ltd. Document 40255-0600