Chapter 5: System Software

Rejector Functions Group

Rejector Status

Disables or enables the reject signal transmitted by the FT-50 to the
rejector. This function also effects the External Reject Function in
the same way. Although the actual rejection is disabled all counters
and alarms continue to accumulate.

Fire Rejector On Demand

Fires the rejector manually. This function is used to test the rejector
mechanism or to manually actuate it during start-up to provide
initial lubrication under no load.
To execute Fire Rejector On Demand:
1. Press Key 4 until FIRE REJECTOR ON DEMAND appears.
2. Press the Arrow Key to fire the rejector.

Rejector Pulse Width

The time in milliseconds that voltage is applied to the rejector
solenoid. This translates into the speed with which the rejector ram
extends and return to the ready position.

Reject Next Container

Defines the number of containers to consecutively reject (also
called Batch Reject). You enter the number of containers to reject
and the FT-50 continues to reject until the counter reaches zero. All
containers rejected with this function are included in the Total
Rejects counter. This function is useful during testing and
calibration procedures.
To activate the Reject Next function:
1. Press Key 4 until REJECT NEXT appears.
2. Press the Arrow Key to enter the number of containers to reject.
Industrial Dynamics Company, Ltd. Document 40255-0600