Servicing The Regulator And Coalescing Air Filters - Filtec FT-50c Service And Technical Reference Manual

Fill level inspector
Table of Contents

Advertisement

Warning
Warning
Industrial Dynamics Company, Ltd. Document 40255-0600
4. Insert the new pad by sliding it onto the shoe. Be sure the notch
in the pad backing is positioned at the bottom.
5. Replace the retaining screw and washer.
6. Power up the rejector.

Servicing the Regulator and Coalescing Air Filters

Servicing the air filter consists of cleaning and/or replacing the air
filter, sediment bowl, and gasket. You can obtain replacement parts
for these items from the air controls manufacturer.
Turn off all power to your system before attempting any repair
procedure. See Before You Perform Any Maintenance Procedure, at
the beginning of this section.
1. Turn off the air flow control valve and depressurize all
connected air lines.
2. Remove and clean the sediment bowl. If your unit contains a
polycarbonate bowl, inspect it for cracking or cloudiness; if
present, replace it.
Cracked or cloudy polycarbonate bowls can explode when
repressurized, causing serious injury.
3. Clean other parts using soap and water.
4. Dry the bowl and other parts, and blow out internal passages
in the body using filtered, dry compressed air.
5. Using filtered, dry compressed air, blow through the filter
element from inside to outside to dislodge surface contami-
nants. If the filter element is plugged, replace it.
6. Apply a light coating of Dow Corning 44M grease (or equiv-
alent) to the bowl gasket, and reassemble.
Chapter 7: Maintenance Procedures
7-7