Power Optimizer Troubleshooting

If the inverter status screen indicates that not all power optimizers are
paired or not all are reporting (P_OK xxx/yyy, and x<y), those optimizers
can be identified through the LCD. Refer to
https://www.solaredge.com/sites/default/files/non_reporting_power_
optimizers.pdf
Malfunction
Pairing failed
String voltage is 0V
String voltage not 0V but lower than
number of optimizers
Three Phase System MAN-01-00507-4.2
Appendix A: Errors and Troubleshooting
Possible Cause and Corrective Action
Power optimizers are shaded.
If you connected the inverter to the monitoring
platform, retry pairing remotely (during
sunlight). Make sure to leave the inverter
ON/OFF switch ON and that S_OK appears in the
status screen.
Power optimizer (s) output is disconnected.
Connect all power optimizer outputs.
Power optimizer(s) not connected in the string.
Connect all power optimizers.
Panel(s) not connected properly to power
optimizer inputs (not applicable to smart
modules).
Connect the modules to the optimizer inputs.
String reverse polarity.
Check string polarity using a voltmeter and
correct if needed.