CAT5/6 standard cables have eight wires (four twisted pairs), as shown in the diagram
below. Wire colors may differ from one cable to another. You can use either wiring
standard, as long as both sides of the cable have the same pin-out and color-coding.
RJ45 Pin #
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
 6. Use a pre-crimped cable to connect via gland #1 to the RJ45 plug on the inverter's
communication board or, if using a spool of cable, connect as follows:
 a. Insert the cable through gland #1.
 b. Remove the cable's external insulation using a crimping tool or cable cutter and
expose eight wires.
 c. Insert the eight wires into an RJ45 connector, as described in Figure 23 .
(1) The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables
depends on the switch capabilities.
Three Phase System MAN-01-00507-4.2
Chapter 7: Setting Up Communication to the Monitoring Platform
Figure 22: Rubber fitting
(1)
Wire Color
T568B
White/Green
White/Orange
White/Brown
Figure 23: Standard cable wiring
T568A
Transmit+
Green
Transmit-
Receive+
Blue
Reserved
White/Blue
Reserved
Orange
Received-
Reserved
Brown
Reserved
    71
10Base-T Signal
100Base-TX Signal