The Pump and DConnect Box 2
do not connect to each other (PLC
DCONNECT BOX2 led steady
red)
(paragraph 10)
The pump does not start and the
status signals error E17
The pump does not start, the
status indicates one of the
following errors: E19, E20, E21,
E22, E23, E24
11

FIRMWARE UPDATE

The ESYBOX DIVER firmware can be updated via cloud or app using DConnect Box 2.
When a new firmware is available, the interface sends a notification and gives the user the opportunity to start the update..
12

CLEANING STORAGE MAINTENANCE

The pump does not require any maintenance. Frost can damage the pump. In very cold temperatures, remove the pump from the
liquid, empty it and store it away from frost. Before any cleaning work is carried out, the pump must be disconnected from the power
mains.
Once the pump has been removed from the liquid, it is advisable to clean the following parts with a simple jet of water:
- Filter (open, see figure 1A)
- Suction filter with float, in case of version X (see figure 3)
- Non-return valve. In this case, remove the part concerned as shown in figure 11.
Be sure to reassemble all parts correctly.
ENGLISH
They are galvanically separated.
They are too far apart.
The two units are not associated (only in case of
replacement of a unit)
Blocked rotor
SW safety error
Table 7 Troubleshooting
Check that the two units are on the same power
supply and in the same phase.
Connect the two units at a shorter distance.
Perform the association procedure
powered
It is necessary to wait 25 minutes with the machine
powered for the automatic restoration of the locked
status.
30
Update Fw version to the latest available
Wait 25 minutes with the machine
for the automatic restoration of the blocked
status
Check that the shaft turns freely