Do you have a question about the ESYBOX DIVER and is the answer not in the manual?
Questions and answers
John Blamey
March 24, 2025
Can the set point pressure be changed without being connected to the app?
1 comments:
Mr. Anderson
March 24, 2025
Yes, the set point pressure of the DAB ESYBOX DIVER can be changed without using the app by using the DConnect Box. However, without the control box, the pump will operate at the preset factory pressure setting (approximately 40-45 PSI) unless the installer increases the pressure setpoint in advance.
Page 1
INSTRUKCJA MONTAŻU I KONSERWACJI (PL) INSTALLÁCIÓS ÉS KARBANTARTÁSI KÉZIKÖNYV (HU) INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO (PT) ИНСТРУКЦИЯ ЗА МОНТИРАНЕ И ПОДДРЪЖКАТА (BG) (ﺗﻌﻠﯿﻤﺎت اﻟﺘﺮﻛﯿﺐ واﻟﺼﯿﺎﻧﺔ )اﻟﻠﻐﺔ اﻟ ﻌ َ ﺮ َ ﺑ ِ ﯿ ّ ﺔ ESYBOX DIVER...
Page 2
ITALIANO pag. ENGLISH page FRANÇAIS page DEUTSCH seite NEDERLANDS pag. ESPAÑOL pág. РУССКИЙ стр. ČEŠTINA strana SUOMI sivu SVENSKA sid. ROMÂNĂ pag. ΕΛΛΗΝΙΚΑ σελίδα TÜRKÇE POLSKI strona MAGYAR oldal pag. PORTUGUÊS БЪЛГАРСКИ Стр. اﻟﻠﻐﺔ اﻟﻌﺮﺑﯿﺔ اﻟﺻﻔﺣﺔ...
ENGLISH To improve immunity to the possible noise radiated towards other appliances it is recommended to use a separate electrical duct to supply the inverter. The appliance may be used by children over 8 years old and by persons with reduced physical, sensory or mental capacities, or who lack experience or knowledge, on condition that they are under supervision or after they have received instructions concerning the safe use of the appliance and the understanding of the dangers involved.
Maximum size of solid particles dispersed in the liquid: Diameter 1 mm (0.04 in) Technical Data ESYBOX DIVER pumps are equipped with a filter, which can be opened (see figure 1, A) or closed (called X) (see figure 1, B), depending on the application.
The ESYBOX DIVER pumps already contain a small expansion tank, calibrated for water hammer and small leaks. In order to reduce the number of pump starts, an auxiliary tank (Figure 6, A) with a capacity of 2 litres can be installed.
Leakage current to earth < 5mA. Do not remove the label on the power cable of the ESYBOX DIVER because it will be useful in case of future changes and configurations of the system.
ENGLISH Installation example ACCESSORIES Accessories available Accessory Description KIT X* Raised suction NFC FLOATER* Level float for stopping the pump NFC WATER LEVEL MEASUREMENT Measurement of the water left in the tank with level float function SACRIFICIAL ANODE Protection against galvanic corrosion DOC68 Surface pump conversion kit * The minimum overall dimensions of the pump with float inside a well or tank are as follows:...
In order to communicate, ESYBOX DIVER and DCONNECT BOX 2 must be associated with each other and this operation is already done in the factory. Once powered, the two units connect in a few minutes. During the device search phase, the PLC led (1) will blink regularly and once correctly connected the led will remain on with a steady light.
Page 13
ENGLISH Disconnect ESYBOX DIVER from the mains and wait 1 min Access DCONNECT BOX2 via Dconnect APP Access Dconnect APP via smartphone Press the Dconnect BOX2 key for 5s, press direct Connection and until the wifi led blinks. select the product "Dconnect Box2".
Check the PLC led status on DCONNECT BOX 2. When it remains on with a steady light, the association has been successful. At this point, your ESYBOX DIVER will also be present in the installation menu, and you can access the current status and configurations.
Page 15
ENGLISH C1: Current display Motor phase current in [A]. SV: Supply voltage TE: Dissipator temperature display Number of starts 7.10 Saving Saving achieved compared to using an ON/OFF type pump 7.11 Energy consumption current month 7.12 Energy consumption previous month 7.13 Flow delivered in current month 7.14...
Page 16
ENGLISH 7.24 AE: Enabling the anti-block function The anti-blocking function avoids mechanical blocks in the case of long inactivity; it acts by periodically rotating the pump. When the function is enabled, every 23 hours the pump performs an unblocking cycle lasting 1 min. 7.25 AF: Enabling the anti-freeze function If the antifreeze function is enabled the pump is automatically rotated when the temperature reaches values close to freezing point, in order to...
ENGLISH 7.35 RF: Resetting errors Deletes Fault and Warning history. 7.36 Error Display Display of the errors that have occurred during system operation. 7.37 Manual reset of error conditions Forces the deletion of the present error. 7.38 Firmware release 7.39 Firmware update 7.40 Factory settings...
ENGLISH In Basic mode, once the condition of recurrence is detected the pump stops and remains waiting to be manually reset. This condition is communicated to the user with the "ANTICYCLING” message. After the leak has been removed, you can manually force restart by sending the Error Reset command.
ENGLISH Factory settings Identifying code Description Value Installation Memo Setpoint pressure [bar] Pressure decrease to restart [bar] Type of plant Rigid Blockage time due to dry operation [s] Delay in switching off [s] Proportional gain coefficient Integral gain coefficient Maximum speed [rpm] 5000 Enabled Anti-blocking function...
Table 7 Troubleshooting FIRMWARE UPDATE The ESYBOX DIVER firmware can be updated via cloud or app using DConnect Box 2. When a new firmware is available, the interface sends a notification and gives the user the opportunity to start the update..
Need help?
Do you have a question about the ESYBOX DIVER and is the answer not in the manual?
Questions and answers
Can the set point pressure be changed without being connected to the app?
Yes, the set point pressure of the DAB ESYBOX DIVER can be changed without using the app by using the DConnect Box. However, without the control box, the pump will operate at the preset factory pressure setting (approximately 40-45 PSI) unless the installer increases the pressure setpoint in advance.
This answer is automatically generated