The following can be carried out by a competent person
Problem
1 Water too hot.
2 Water too cold.
3 High water flow
and/or poor
performance on a
mains fed system.
Push button mixer shower

FAULT FINDING

Cause
1.1 Temperature
control incorrectly
commissioned.
1.2 Not enough cold
water flowing through
shower.
1.3 Increase in the
ambient cold water
temperature.
1.4 Cold water supply
blocked.
1.5 High volume of cold
water drawn off
elsewhere.
2.1 Temperature
control incorrectly
commissioned.
2.2 Not enough hot water
flowing through mixer
shower.
2.3 Decrease in the
ambient cold water
temperature.
2.4 Insufficient hot water
supplies from the
heating system.
2.5 Hot water supply
blocked or restricted.
2.6 Flow regulator not
fitted (HP systems
only).
3.1 Flow regulators not
fitted.
Action
1.1.1 Refer to the Commissioning section.
1.2.1 Reposition temperature control knob
1.3.1 Reposition temperature control knob.
1.4.1 Turn off the mixer shower and consult
a competent plumber or contact Triton
Customer Experience.
1.5.1 Reduce the simultaneous demand from the
supply.
2.1.1 Refer to the Commissioning section.
2.2.1 Reposition temperature control knob
2.3.1 Reposition temperature control knob
2.4.1 Make sure heating appliance is set to
maximum or has sufficient stored hot water.
2.4.2 Make sure heating appliance is igniting by
trying a hot water tap elsewhere.
2.5.1 Turn off mixer shower and consult a
competent plumber or contact Triton
Customer
Experience.
2.6.1 Contact Triton Customer Experience.
3.1.1 Contact Triton Customer Experience.
18