Cisco MDS 9500 Series Hardware Installation Manual

Cisco systems network device installation guide
Hide thumbs Also See for MDS 9500 Series:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Cisco MDS 9500 Series Hardware
Installation Guide
August 2009
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-19587-01

Advertisement

Table of Contents
loading

Summary of Contents for Cisco MDS 9500 Series

  • Page 1 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware...
  • Page 2 Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system.
  • Page 3 Cisco MDS 9506 Power Supplies Fan Modules Supervisor Modules Supervisor-2 Modules OL-19587-01 xvii xvii xviii xxii 1-10 1-12 1-15 1-16 1-16 1-17 Control and Management 1-18 Processor 1-18 C O N T E N T S xxii Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 4: Table Of Contents

    LEDs on the Fibre Channel Advanced Services Modules 32-Port Fibre Channel Storage Services Module LEDs on the Storage Services Modules Caching Services Module LEDs on the Caching Services Module Supported Transceivers Cisco MDS 9500 Series Hardware Installation Guide 1-18 1-19 1-21 1-21 1-22...
  • Page 5 Providing Power to a DC Power Supply in the Cisco MDS 9509 Director Providing Power to a DC Power Supply in the Cisco MDS 9506 Director 2-39 2-40 2-44 1-57 1-57 1-58 2-11 2-15 2-19 2-33 2-34 2-36 2-38 2-45 2-46 2-47 Cisco MDS 9500 Series Hardware Installation Guide Contents 2-29 2-45...
  • Page 6 Installing a Clock Module into the Cisco MDS 9509 Director Removing a Clock Module from the Cisco MDS 9506 Director Installing a Clock Module into the Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide 2-50 2-50 2-51...
  • Page 7 Switch A-11 Cabinet and Rack Requirements for the Cisco MDS 9513 Chassis Cabinet and Rack Requirements for the Cisco MDS 9509 and Cisco MDS 9506 Chassis 3-12 3-14 3-14 3-15 3-16 A-12 Cisco MDS 9500 Series Hardware Installation Guide Contents...
  • Page 8 Specifications for the Cisco MDS 9509 Power Supplies Component Power Requirements and Heat Dissipation for the Cisco MDS 9509 Director AC Power Consumption for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide viii Perforated Cabinet Requirements for the Cisco MDS 9513 Chassis...
  • Page 9 Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet Transceivers C-34 C-35 C-14 C-15 C-19 C-20 C-20 C-21 C-21 C-22 C-23 C-26 C-27 C-28 C-34 Cisco MDS 9500 Series Hardware Installation Guide Contents C-16 C-24 C-26 C-27 C-28 C-29 C-31 C-33...
  • Page 10 Contact and Site Information Chassis and Module Information N D E X Cisco MDS 9500 Series Hardware Installation Guide Supported Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies Supported Plugs for the 4000-W AC Power Supply D-11...
  • Page 11: New And Changed Information

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m New and Changed Information The Cisco MDS 9500 Series Hardware Installation Guide applies to Cisco MDS NX-OS Release 4.2(1) and earlier Cisco MDS SAN-OS releases.
  • Page 12 18/4-port Multiservice (MSM-18/4) module Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 24-port 8-Gbps Fibre Channel switching module. The switching module offers 24 autosensing 1-, 2-, 4- and 8-Gbps Fibre Channel ports and can be used in the Cisco MDS 9500 Series Switches.
  • Page 13 Crossbar modules X2 transceiver OL-19587-01 Documented Features for the Cisco MDS 9500 Series (continued) Description Added Cisco MDS 9513 Multilayer Director. The chassis consists of 13 horizontal slots, where slots 1 to 6 and slots 9 to 13 are reserved for switching,...
  • Page 14 (IPS-4) module Jumper power cord Installation Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 4-Gbps Fibre Channel SFP trans- ceiver. Added 3000W power supply for the Cisco MDS 9509 Director.
  • Page 15 Cisco MDS 9506 Director 16-port Fibre Channel module OL-19587-01 Documented Features for the Cisco MDS 9500 Series (continued) Description 9509 power supplies. Added instructions for installation and removal of SFP transceivers and cables. Added United Kingdom power cable BS89/13, BS 1363/A, for use with 1900-W power supply.
  • Page 16 Channel module Cisco MDS 9509 Switch Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 32-port Fibre Channel hot-swappable switching module for use with the Cisco MDS 9500 Series. Added the Cisco MDS 9509 Director, a multilayer Fibre Channel switch that supports up to nine modules.
  • Page 17: A P P E N D I X A Migrating To Generation 3 8-Gbps Fibre Channel Switching Modules

    Appendix C Technical Specifications OL-19587-01 Description Provides an overview of the Cisco MDS 9500 Series and its components. Describes how to install the Cisco MDS 9500 Series, including installing the chassis, modules, CompactFlash card, power supplies, and fan assembly. Describes how to connect the Cisco MDS 9500 Series, including the modules.
  • Page 18 Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Cisco MDS 9500 Series Hardware Installation Guide xviii Description Lists cable and port specifications for the Cisco MDS 9500 Series switch. Provides a site-planning checklist and sample maintenance and network records. Preface...
  • Page 19 Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo. Cisco MDS 9500 Series Hardware Installation Guide OL-19587-01...
  • Page 20: Related Documentation

    Hardware Installation Cisco MDS 9200 Series Hardware Installation Guide • Cisco MDS 9100 Series Hardware Installation Guide • Cisco MDS 9124 and Cisco MDS 9134 Multilayer Fabric Switch Quick Start Guide • Cisco MDS 9500 Series Hardware Installation Guide Preface OL-19587-01...
  • Page 21: Cisco Fabric Manager

    • Cisco Fabric Manager Inter-VSAN Routing Configuration Guide • • Cisco Fabric Manager Online Help • Cisco Fabric Manager Web Services Online Help Command-Line Interface • Cisco MDS 9000 Family Command Reference OL-19587-01 Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 22 Cisco MDS 9000 Family NX-OS Troubleshooting Guide • Cisco MDS 9000 Family NX-OS MIB Quick Reference • • Cisco MDS 9000 Family NX-OS SMI-S Programming Reference • Cisco MDS 9000 Family Fabric Manager Server Database Schema Cisco MDS 9500 Series Hardware Installation Guide xxii Preface OL-19587-01...
  • Page 23: Product Overview

    The Cisco MDS 9500 Series includes the Cisco MDS 9513 Director, the Cisco MDS 9509 Director, and the Cisco MDS 9506 Director, which all provide the following high availability features: Redundant Supervisor-2 modules with associated external crossbar modules for the Cisco MDS •...
  • Page 24 Services Modules, page 1-41 • Supported Transceivers, page 1-56 • Chassis This section describes the different chassis offerings in the Cisco MDS 9500 Series: • Cisco MDS 9513 Director, page 1-3 Cisco MDS 9509 Director, page 1-6 • Cisco MDS 9506 Director, page 1-7 •...
  • Page 25: Chassis

    Two hot-swappable clock modules located at the rear of the chassis. • The Cisco MDS 9513 Director does not support the Advanced Services Module (ASM) or the Caching Note Services Module (CSM). OL-19587-01 “Port Index Availability” section on page 1-28 Cisco MDS 9500 Series Hardware Installation Guide Chassis...
  • Page 26 The rear of the chassis supports two vertical, redundant power supplies, two clock modules, two vertical, redundant, external crossbar modules, and a variable speed fan tray with two individual fans located above the crossbar modules. (See Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9513 Chassis Front Panel View Figure 1-2.)
  • Page 27 1. Clock modules are located inside the air vent panel. You must remove the air vent panel to access the clock modules. OL-19587-01 Rear Panel 9513 Chassis Cisco MDS 9500 Series Hardware Installation Guide Air vent panels Clock module Chassis...
  • Page 28 2 Supervisor module in slot 5 3 Redundant supervisor module in slot 6 4 Switching or services modules in slots 7–9 Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9509 Chassis 5 Fan module 6 Power supply 1 7 ESD socket...
  • Page 29 Switching or services modules in slots 1–4 Supervisor modules in slots 5 and 6 Fan module OL-19587-01 Cisco MDS 9506 Chassis Cisco MDS 9500 Series Hardware Installation Guide Figure 1-4, and it supports the following: ESD Socket Power supplies (in back) Location of power entry modules (PEMs) -- one PEM shown and one filler panel shown.
  • Page 30: Backplane And Clock Modules

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Backplane and Clock Modules The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of the chassis. The Cisco MDS 9513 and 9509 Directors have two field-replaceable clock modules for redundancy and failover.
  • Page 31: Cisco Mds Fibre Channel Switch For Ibm Blade Center

    Reference. Power Supplies The Cisco MDS 9500 Series supports dual hot-swappable power supplies, each of which is capable of supplying sufficient power to the entire chassis should one power supply fail. The power supplies monitor their output voltage and provide status to the supervisor modules. To prevent the unexpected shutdown of an optional module, the power management software only allows a module to power up if adequate power is available.
  • Page 32 Cisco MDS 9513 Power Supplies The Cisco MDS 9513 Director supports the 6000-W AC power supply (AC input). (See Figure 1-6 Power supply switch AC power connection Cisco MDS 9500 Series Hardware Installation Guide 1-10 Cisco MDS 9513 Power Supply Chapter 1 Product Overview...
  • Page 33 Green Green Green Green Green Cisco MDS 9500 Series Hardware Installation Guide Power Supplies Description AC input at greater than 85 V is good and power supply is functioning normally if two single 110 V or one single 220 V are connected.
  • Page 34 2500-W DC power supply (DC input and DC output) • The 2500-W DC power supply requires positive, negative, and ground wires. (See Figure 1-7 1 AC power connection 2 Power supply LEDs 3 Captive screws Cisco MDS 9500 Series Hardware Installation Guide 1-12 Figure 1-7.) Figure Figure 1-9.)
  • Page 35 Figure 1-8 1 AC power connection 2 Power cable 3 Power supply switch OL-19587-01 3000-W AC Power Supply for the Cisco MDS 9509 Director 4 Power supply LEDs 5 Captive screws Cisco MDS 9500 Series Hardware Installation Guide Power Supplies 1-13...
  • Page 36 3 Power supply switch Figure 1-10 1 Terminal block cover 2 Power supply LEDs 3 Captive screw Cisco MDS 9500 Series Hardware Installation Guide 1-14 2500-W AC Power Supply for the Cisco MDS 9509 Director INPU T OUT PUT FAIL...
  • Page 37 2 Captive screws Power Supply LEDs for the Cisco MDS 9509 and 9506 Directors Status Green Green Cisco MDS 9500 Series Hardware Installation Guide Power Supplies Figure 1-11), except for the label Description AC input is good and power supply is functioning normally.
  • Page 38: Fan Modules

    Both the supervisor modules provide the control and management functions for the Cisco MDS 9500 Series. The Cisco MDS 9500 Series supports two supervisor modules for redundancy. In the event of an internal component failure, the standby supervisor module takes over, if installed. This section...
  • Page 39: Supervisor Modules

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Supervisor-2 Modules The Cisco MDS 9500 Series offers redundant, hot-swappable, Supervisor-2 modules. (See Supervisor-2 modules can be used in the Cisco MDS 9509 and 9506 Directors in slots 5 and 6.
  • Page 40: Port Interfaces

    Port Interfaces The Supervisor-2 module provides the following port interfaces: RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to: • Configure the Cisco MDS 9500 Series from the CLI – – Monitor network statistics and errors –...
  • Page 41: Leds On The Supervisor-2 Module

    The LEDs on the Supervisor-2 module indicate the status of the Supervisor-2 module, power supplies, and fan module. Figure 1-13 OL-19587-01 Table 1-4 provides more information about these LEDs. Supervisor-2 Module LEDs Cisco MDS 9500 Series Hardware Installation Guide Supervisor Modules Figure 1-13). 1-19...
  • Page 42 MGMT 10/100 Ethernet Activity LED CompactFlash Cisco MDS 9500 Series Hardware Installation Guide 1-20 LEDs for the Cisco MDS 9500 Series Supervisor-2 Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence). Orange One of the following occurs: The module is booting or running diagnostics •...
  • Page 43: Supervisor-1 Modules

    LEDs on the Supervisor-1 Module, page 1-23 • Note Supervisor-1 is not supported on the Cisco MDS 9513 Director. Figure 1-14 shows a Cisco MDS 9500 Series Supervisor-1 module. Figure 1-14 1 Status, System, Active, and Pwr Mgmt LEDs 2 Reset button...
  • Page 44: Crossbar Switching Fabric

    192-Gbps full duplex bandwidth per switching module. The Cisco MDS 9500 Series supports redundant supervisor modules. Upon power up with slots 5 and 6 active, the supervisors negotiate to determine which one is active and which is the standby supervisor.
  • Page 45: Leds On The Supervisor-1 Module

    The LEDs on the Supervisor-1 module indicate the status of the Supervisor-1 module, power supplies, and fan module. Figure 1-15 OL-19587-01 Table 1-5 provides more information about these LEDs. Supervisor-1 Module LEDs Cisco MDS 9500 Series Hardware Installation Guide Supervisor Modules Figure 1-15). 1-23...
  • Page 46 1. The System and Pwr Mgmt LEDs on a redundant supervisor module are synchronized to the active supervisor module. Cisco MDS 9500 Series Hardware Installation Guide 1-24 LEDs for the Cisco MDS 9500 Series Supervisor Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence).
  • Page 47: Crossbar Modules

    LEDs. For information regarding migrating to Generation 3 modules, see the “Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules” section on page A-1. Figure 1-16 Crossbar Module LEDs 181335 Cisco MDS 9500 Series Hardware Installation Guide 1-25 OL-19587-01...
  • Page 48 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Table 1-6 Status Cisco MDS 9500 Series Hardware Installation Guide 1-26 LEDs for the Cisco MDS 9500 Crossbar Modules...
  • Page 49: Cisco Mds 9000 Series Module Compatibility

    18-port Fibre Channel and 4-port Gigabit Ethernet IP Services (MSM-18/4) module 14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module OL-19587-01 Cisco MDS 9000 Series Module Compatibility 9513 9509 9506 9222i 9216A Cisco MDS 9500 Series Hardware Installation Guide 9216i 9216 1-27...
  • Page 50: Port Index Availability

    Using any combination of modules that include a Generation 1 module or a Supervisor-1 module limits the port index availability to 252 on all Cisco MDS 9500 Series directors. Generation 1 modules also require contiguous port indexes where the system assigns a block of port index numbers contiguously...
  • Page 51 Using any combination of modules that include a Generation 1 module and a Supervisor-2 module limits the port index availability to 252 on all Cisco MDS 9500 Series Directors. The Generation 1 modules can use any contiguous block of port indexes that start on the first port index reserved for any slot in the range 0-252.
  • Page 52: Table

    Generation 1 storage IPS modules and Generation 2 modules on a Cisco MDS 9509 Director. In this example, one of the modules installed will not boot up because the number of port indexes needed has been exceeded. Cisco MDS 9500 Series Hardware Installation Guide 1-30 Port Index Requirements...
  • Page 53 Using any combination of modules that include a Generation 1 module and a Supervisor-2 module limits the port index availability to 252 on all Cisco MDS 9500 Series Directors. But the Generation 1 modules can use any contiguous block of port indexes in the range 0–252 (See Using any combination of only Generation 2 with a Supervisor-2 module allows a maximum of 528 (with an architectural limit of 1020) port indexes on all Cisco MDS 9500 Series Directors.
  • Page 54: Switching Modules

    16-Port 2-Gbps Fibre Channel Switching Module – The Cisco MDS 9500 Series supports up to eleven hot-swappable switching modules. By combining different switching modules in a single, modular chassis, you can design cost and performance optimized storage networks in a wide range of application environments.
  • Page 55: 48-Port 8-Gbps Fibre Channel Switching Module

    The 4/44-port 8-Gbps Host-Optimized Fibre Channel switching module offers 48 autosensing 1-, 2-, 4- and 8-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9222i Switches. The 48-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
  • Page 56: 48-Port 4-Gbps Fibre Channel Switching Module

    The 48-port 4-Gbps Fibre Channel switching module offers 48 autosensing 1-, 2-, and 4-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. The 48-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
  • Page 57: 24-Port 4-Gbps Fibre Channel Switching Module

    The 24-port 4-Gbps Fibre Channel switching module offers 24 autosensing 1-, 2-, and 4-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. The 24-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
  • Page 58: 4-Port 10-Gbps Fibre Channel Switching Module

    4-port 10-Gbps switching module. The front panel connectors support standard modular X2 interfaces and the speed is fixed at 10 Gbps. Figure 1-24 Status LED X2 port interfaces Cisco MDS 9500 Series Hardware Installation Guide 1-36 4-Port 10-Gbps Fibre Channel Switching Module Chapter 1 Product Overview...
  • Page 59: Leds On The Generation 2 Switching Modules

    Link is up. Link is up (traffic on port). Link is disabled by software. A fault condition exists. No link. Cisco MDS 9500 Series Hardware Installation Guide Switching Modules Figure 1-25 shows a 1-37...
  • Page 60: 16-Port 2-Gbps Fibre Channel Switching Module

    Figure 1-26 1 Status LED 2 1-Gbps/2-Gbps Fibre Channel ports Cisco MDS 9500 Series Hardware Installation Guide 1-38 Cisco MDS 9000 Family 32-Port 2-Gbps Switching Module 3 Link LEDs (under ports, on left) and Speed LEDs (under ports, on right)
  • Page 61: Switching Module Features

    Each switching module has a hardware watchdog timer for detecting most component failures. This watchdog resets the card if is not serviced periodically. Cisco MDS 9500 Series Hardware Installation Guide 1-39 OL-19587-01...
  • Page 62: Leds On The Generation 1 Switching Module

    Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide. Cisco MDS 9500 Series Hardware Installation Guide 1-40 LEDs for the Cisco MDS 9000 Family Generation 1 Fibre Channel Switching Modules Description All diagnostics pass.
  • Page 63: Services Modules

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Services Modules The Cisco MDS 9500 Series supports the following hot-swappable Generation 1 services modules: 16-Port Storage Services Module, page 1-41 •...
  • Page 64 The module provides intelligent diagnostics, protocol decoding, and network analysis tools as well as integrated Call Home capability for added reliability, faster problem resolution, and reduced service costs. Cisco MDS 9500 Series Hardware Installation Guide 1-42 Link LEDs Chapter 1...
  • Page 65: 18/4-Port Multiservice Module

    FCIP, iSCSI, and management traffic routed in-band and out-of-band. The MSM-18/4 provides intelligent diagnostics, protocol decoding, and network analysis tools with the integrated Call Home capability. Figure 1-28 shows the MSM-18/4 module. Figure 1-28 OL-19587-01 18/4-Port Multiservice Module Cisco MDS 9500 Series Hardware Installation Guide Services Modules 1-43...
  • Page 66: Leds On The 18/4-Port Multiservice Module

    Solid green Solid yellow Flashing yellow Cisco MDS 9500 Series Hardware Installation Guide 1-44 LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules Description All diagnostics pass. The module is operational (normal initialization sequence). One of the following occurs or occurred: •...
  • Page 67: 14/2-Port Multiprotocol Services Module

    (CWDM) SFP transceivers, which can be used for extended long wavelength (ELWL) transmission or for CWDM. See the “Supported Transceivers” section on page 1-56. Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release Note 4.1(1b) support the MPS-14/2 module. Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 68: Leds On The Mps-14/2 Module

    Table 1-16 describes the LEDs for the MPS-14/2 modules. Table 1-16 Status Status Green Orange Speed On Cisco MDS 9500 Series Hardware Installation Guide 1-46 Cisco MDS 9000 Family MPS-14/2 Module —SPEED LINK— —SPEED LINK— LEDs for the Cisco MDS 9000 Family MPS-14/2 Modules Description All diagnostics pass.
  • Page 69: Ip Storage Services Modules

    Link is disabled by software. A fault condition exists. No link. “Supported Transceivers” section on page Cisco MDS 9000 Family IPS-8 Services Module 3 Link LEDs 4 Asset tag Cisco MDS 9500 Series Hardware Installation Guide Services Modules 1-56. 1-47...
  • Page 70: Leds On Ip Storage Services Modules

    Solid green Flashing green Solid yellow Flashing yellow Cisco MDS 9500 Series Hardware Installation Guide 1-48 Cisco MDS 9000 Family IPS-4 Services Module LINK LINK LINK 3 Link LEDs 4 Asset tag LEDs for the Cisco MDS 9000 Family IPS Module Description All diagnostics pass.
  • Page 71: 32-Port Fibre Channel Advanced Services Module

    ASM-SFN boot variable, see the Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration OL-19587-01 1-56. Fibre Channel ASM 3 Link and Speed LEDs 4 Asset tag Guide. Cisco MDS 9500 Series Hardware Installation Guide Services Modules “Supported 1-49...
  • Page 72: Leds On The Fibre Channel Advanced Services Modules

    Table 1-18 describes the LEDs for the Advanced Services module. Table 1-18 Status Speed Link Cisco MDS 9500 Series Hardware Installation Guide 1-50 LEDs for the Cisco MDS 9000 Family Fibre Channel ASMs Status Description Green All diagnostics pass and the module is operational (normal initialization sequence).
  • Page 73: 32-Port Fibre Channel Storage Services Module

    32 Fibre Channel ports, provides distributed intelligent storage services, and supports future storage services. Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release 4.1(1b) support the SSM. The Fibre Channel ports support hot-swappable Fibre Channel SFP transceivers, which can be short wavelength (SWL) for connectivity up to 1640 ft (500 m), or long wavelength (LWL) for connectivity up to 6.2 miles (10 km).
  • Page 74: Leds On The Storage Services Modules

    Table 1-19 describes the LEDs for the Storage Services Modules. Table 1-19 Status Speed Link Cisco MDS 9500 Series Hardware Installation Guide 1-52 LEDs for the Cisco MDS 9000 Family Storage Services Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence).
  • Page 75: Caching Services Module

    The batteries are shipped fully charged and should be handled with caution accordingly. OL-19587-01 NODE 1 NODE 2 STATUS DISK STATUS DISK Cisco MDS 9500 Series Hardware Installation Guide Services Modules Disk 1 Status LED Node 2 LEDs Node 2 Status LED Disk 2 Status LED 1-53...
  • Page 76 See the “Installing a Switching or Services Module, Including Caching Services Modules” section on page 2-45 for information about installing the CSM and maintaining the CSM batteries. Cisco MDS 9500 Series Hardware Installation Guide 1-54 CSM, Internal View Chapter 1...
  • Page 77: Leds On The Caching Services Module

    Battery does not have power and is not charged. Solid green Disk is operational. Flashing orange Dumping cache to disk. Flashing green Restoring cache from disk. Disk failure. Disk does not have power. Cisco MDS 9500 Series Hardware Installation Guide Services Modules 1-55...
  • Page 78: Supported Transceivers

    For more information about a specific Cisco SFP transceiver, see the Specifications” section on page 9500 Series. Use only Cisco transceivers in the Cisco MDS 9500 Series. Each Cisco transceiver is encoded with Note model information that enables the switch to verify that the transceiver meets the requirements for the switch.
  • Page 79: Fibre Channel Sfp Transceivers

    SFP+ Transceiver Specifications” section on page Combination Fibre Channel/Gigabit Ethernet SFP Transceivers The combination Fibre Channel/Gigabit Ethernet SFP transceivers from Cisco Systems are available in SWL or LWL versions. Both of these versions are 1-Gbps/2-Gbps capable. The combination SFP transceivers from Cisco Systems have LC connectors and comply with 1-Gbps/2-Gbps Fibre Channel as defined in FC-PI 10.0 2 and Gigabit Ethernet as defined in IEEE...
  • Page 80: Dwdm Fibre Channel Sfp Transceivers

    • ELWL signals can transmit over longer distances than LWL SFP transceivers. For more information about Gigabit Ethernet SFP transceiver specifications, see the Transceiver Specifications” section on page Cisco MDS 9500 Series Hardware Installation Guide 1-58 Chapter 1 C-22. C-22.
  • Page 81: Installing The Cisco Mds 9500 Series

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Installing the Cisco MDS 9500 Series This chapter describes how to install the Cisco MDS 9500 Series chassis and its components, and includes the following information: Preinstallation, page 2-2 •...
  • Page 82: Preinstallation

    – rack-mount kit shipped with the switch In a perforated or solid-walled EIA cabinet, using: • The rack-mount kit shipped with the switch – Cisco MDS 9500 Series Hardware Installation Guide Chapter 2 Installing the Cisco MDS 9500 Series OL-19587-01...
  • Page 83: Installation Guidelines

    The telco and EIA Shelf Bracket Kit is not intended for use with a Cisco MDS 9513 Director or Cisco MDS 9509 Director in a two-post telco rack. Installation Guidelines Follow these guidelines when installing the Cisco MDS 9500 Series: • Plan your site configuration and prepare the site before installing the chassis. Cisco recommends...
  • Page 84 M3 screws: 4 in-lb M4 screws: 12 in-lb – M6 screws: 20 in-lb – 10-32 screws: 20 in-lb – 12-24 screws: 30 in-lb – Cisco MDS 9500 Series Hardware Installation Guide Chapter 2 Installing the Cisco MDS 9500 Series Appendix E, “Site OL-19587-01...
  • Page 85: Required Equipment

    An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded either through the power cable, the chassis ground, or metal-to-metal contact with a grounded rack. OL-19587-01 Cisco MDS 9500 Series Hardware Installation Guide Preinstallation...
  • Page 86: Installing The Chassis In A Cabinet Or Rack

    Installing the Chassis in a Cabinet or Rack This section describes how to install the Cisco MDS 9500 Series in a cabinet or rack that meets the requirements described in this document, using the rack-mount kit provided with the switch. A separate procedure is provided for each type of director: •...
  • Page 87: Installing The Cisco Mds 9513 Director In A Rack

    Contents for the Rack-Mount Support Bracket Kit Part Description Rack-mount support bracket Rack-mount support bar 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack...
  • Page 88 Install one rack-mount support bar into the slots located on the rack-mount support brackets. Repeat this for the other support bar. Cisco MDS 9500 Series Hardware Installation Guide 2-1). The top four screws will be used to install the cable management bracket to the rail.
  • Page 89 These will be installed after placing the cable management bracket along that side. The bottom screw should be installed to support the front of the rack-mount support bracket. OL-19587-01 Rack-mount support bar Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack...
  • Page 90 3/4-inch or 10-32 x 3/4-inch screws, using six screws per side. (See Use a minimum of six screws to ensure that the switch is adequately supported. Note Cisco MDS 9500 Series Hardware Installation Guide 2-10 Securing the Rack-Mount Support Brackets...
  • Page 91: Installing The Cisco Mds 9509 Director In A Rack

    Cisco MDS 9509 rack-mount kit. OL-19587-01 Installing the Cable Management Brackets on the MDS 9513 Chassis 3 Mounting rail 4 Cable guide Installing the Chassis in a Cabinet or Rack Cisco MDS 9500 Series Hardware Installation Guide 2-11...
  • Page 92 Step 2 Repeat for the second side rack-mount bracket, ensuring that the side rack-mount brackets are at the same height. Cisco MDS 9500 Series Hardware Installation Guide 2-12 “Cisco MDS 9500 Shelf Bracket” section on page Contents of Cisco MDS 9509 Rack-Mount Kit...
  • Page 93 2 Screws, 12-24 or 10-32 2-6. Attaching the Crossbar to the Side Rack-Mount Brackets (Rear View) Front of rack 3 Screws, M3 4 Crossbar Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack 2-13...
  • Page 94 3/4-inch or 10-32 x 3/4-inch screws (see Use a minimum of six screws per side to ensure that the switch is adequately supported. Note Cisco MDS 9500 Series Hardware Installation Guide 2-14 Installing the Cisco MDS 9509 Chassis in the Rack...
  • Page 95: Installing The Cisco Mds 9506 Director In A Rack

    Cisco MDS 9506 Director. OL-19587-01 Installing the Cable Management Bracket on the MDS 9509 Chassis 3 Mounting rail 4 Cable guide Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack 2-15...
  • Page 96 Figure 2-9 Screws, 12-24 or 10-32 Front rack-mount bracket (behind cable guide) Cisco MDS 9500 Series Hardware Installation Guide 2-16 Contents of Cisco MDS 9506 Rack-Mount Kit Installing the Cisco MDS 9506 Chassis in the Rack Chapter 2 Installing the Cisco MDS 9500 Series...
  • Page 97: System Grounding

    OL-19587-01 Figure 2-9), supporting the switch inside the rack until the next step is Cisco MDS 9500 Series Hardware Installation Guide System Grounding Table 2-4 2-17...
  • Page 98 Existing commercial building is not subject to natural environmental noise or man-made industrial noise. This building contains a standard office environment. Cisco MDS 9500 Series Hardware Installation Guide 2-18 Grounding Best Practices Electromagnetic Noise Severity Level High High...
  • Page 99: Preventing Electrostatic Discharge Damage

    If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your bare skin. OL-19587-01 2-22. Cisco MDS 9500 Series Hardware Installation Guide System Grounding “Establishing the 2-19...
  • Page 100 If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel. Cisco MDS 9500 Series Hardware Installation Guide 2-20...
  • Page 101 If you plan to return the component to the factory, immediately place it in a static shielding container. OL-19587-01 Attaching the ESD Wrist Strap to the System Ground Lug Screw 2 pt Cisco MDS 9500 Series Hardware Installation Guide System Grounding Clip installed (behind screw) System ground connector 2-21...
  • Page 102: Establishing The System Ground

    AC-input or DC-input power supplies, you do not need to power down the chassis. Note The system (NEBS) ground serves as the primary safety ground for the MDS 9500 series chassis that are equipped with DC-input PEMs. The DC-input power supplies for these chassis do not have a separate ground.
  • Page 103: Grounding The Chassis

    Wire-stripping tool to remove the insulation from the grounding wire. Grounding the Chassis This section describes how to connect the Cisco MDS 9500 Series to earth ground. You must complete this procedure before connecting system power or powering up your shelf.
  • Page 104 NRTL listed grounding lug Figure 2-12 shows the ESD ground location on the rear panel of the Cisco MDS 9513 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-24 System Ground Location on the Cisco MDS 9513 Chassis (Front) Chapter 2...
  • Page 105 For a Cisco MDS 9506 Director with a DC power supply, the chassis ground is required. Figure 2-13 shows the system ground location on the Cisco MDS 9509 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-25 OL-19587-01...
  • Page 106 NEC code for ampacity. Figure 2-14 shows the system ground location on the Cisco MDS 9506 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-26 System Ground Location on the Cisco MDS 9509 Chassis 4 Screws, M4, with square cone washers...
  • Page 107 OL-19587-01 System Ground Location on the Cisco MDS 9506 Chassis 4 Screws, M4, with square cone washers 5 NRTL listed grounding lug 6 Close-up of grounding pad on switch Cisco MDS 9500 Series Hardware Installation Guide Grounding the Chassis 2-27...
  • Page 108: Starting Up The Switch

    Providing Power to a DC Power Supply in the Cisco MDS 9509 Director, page 2-33 • Providing Power to a DC Power Supply in the Cisco MDS 9506 Director, page 2-34 Cisco MDS 9500 Series Hardware Installation Guide 2-28 Chapter 2 Installing the Cisco MDS 9500 Series Appendix C, “Technical Specifications.”...
  • Page 109: Providing Power To An Ac Power Supply For The Cisco Mds 9513 Director

    FAN OK LEDs are green. • OUTPUT FAIL LED is off. • Table 1-2 on page 1-11 OL-19587-01 Cable Retention on the Power Supply for power supply LED details. Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch Cable retention 2-29...
  • Page 110: Directors

    2 Power cable retainer 3 Power supply switch Figure 2-17 shows a 4000-W AC power supply for the Cisco MDS 9509 Director. Cisco MDS 9500 Series Hardware Installation Guide 2-30 2500-W AC Power Supply for the Cisco MDS 9509 Director INPU T...
  • Page 111 4000-W AC Power Supply for the Cisco MDS 9509 Director INPU T OUT PUT FAIL 4 Power supply switch 5 Permanent power cable AC PEM for Cisco MDS 9506 Director 3 AC power connection Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch 2-31...
  • Page 112 Note Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9500 Series director to your outlet receptacle. See “Jumper Power Cord” section on page Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 113: Providing Power To A Dc Power Supply In The Cisco Mds 9509 Director

    OL-19587-01 2-17. 2500-W DC Power Supply for the Cisco MDS 9509 Director INP UT OUT PUT FAIL 4 Power supply switch 5 Terminal block Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch “System Grounding” 2-33...
  • Page 114: Providing Power To A Dc Power Supply In The Cisco Mds 9506 Director

    Providing Power to a DC Power Supply in the Cisco MDS 9506 Director Before performing any of the following procedures, ensure that power is removed from the DC circuit. Warning Statement 1003 Cisco MDS 9500 Series Hardware Installation Guide 2-34 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding”...
  • Page 115 OL-19587-01 2-17. DC PEM for a Cisco MDS 9506 Director 4 Exposed portion of positive cable 5 Insulated portion of negative cable Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch “System Grounding” “System Grounding” section on 2-35...
  • Page 116: Powering Up The Switch And Verifying Component Installation

    Fundamentals Configuration Guide or the Cisco Fabric Manager Fundamentals Configuration Guide. For instructions on connecting to the console port, see the page 3-2). Cisco MDS 9500 Series Hardware Installation Guide 2-36 Chapter 2 Installing the Cisco MDS 9500 Series “Connecting to the Console Port” section on...
  • Page 117 If a component is not operating correctly, try removing and reinstalling it. If it still does not operate correctly, contact your customer service representative for a replacement. OL-19587-01 Appendix C, “Technical Specifications,” Appendix C, “Technical Specifications.” Starting Up the Switch “System Grounding” section on for the required voltages. Cisco MDS 9500 Series Hardware Installation Guide 2-37...
  • Page 118: Removing, Installing, And Verifying Supervisor, Switching, And Services Modules

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Step 11 Verify that the system software has booted and the switch has initialized without error messages.
  • Page 119: Removing Supervisor Modules

    Note Install the Cisco MDS 9500 Series chassis in the rack before installing modules. See the Chassis in a Cabinet or Rack” section on page In systems with redundant supervisor modules, you can replace the faulty supervisor while the system Note is operating, provided that one supervisor is always operating.
  • Page 120: Installing Supervisor Modules

    To remove a currently installed module, see the Modules” section on page Open both the ejector levers on the new or replacement module completely. (See Step 5 Cisco MDS 9500 Series Hardware Installation Guide 2-40 Figure 1-3 on page 1-6 Figure 1-4 on page 1-7 2-45.
  • Page 121 (see OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Positioning a Module in the Chassis 3 EMI Gasket 4 Ejector level (fully extended) Figure Cisco MDS 9500 Series Hardware Installation Guide 2-23). 2-41...
  • Page 122 Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create a small 0.040-inch (1-mm) gap between the module’s EMI gasket and the module above it. (See Figure 2-24.) Cisco MDS 9500 Series Hardware Installation Guide 2-42 Clearing the EMI Gasket Press down gently...
  • Page 123 Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Closing the Ejector Levers Ejector levers flush with module faceplate Cisco MDS 9500 Series Hardware Installation Guide 2-43...
  • Page 124: Removing A Caching Services Module

    Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029 Cisco MDS 9500 Series Hardware Installation Guide 2-44 Chapter 2...
  • Page 125: Removing Other Switching And Services Modules

    Verify that the captive screws are tightened to 8 in-lb on all modules already installed in the chassis. This ensures that the EMI gaskets are fully compressed and maximizes the opening space for the module being installed. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules 2-6. Cisco MDS 9500 Series Hardware Installation Guide 2-45...
  • Page 126: Verifying Installation Of Supervisor, Switching, And Services Modules

    8 in-lb. Step 3 Verify that any empty module slots have filler panels installed and that the screws holding the panels in place are tight. Cisco MDS 9500 Series Hardware Installation Guide 2-46 “Removing Other Switching and Services 2-45.
  • Page 127: Removing And Installing A Crossbar Module

    Hold the front edge of the module and slide the module partially out of the slot. Do not touch the module circuitry. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Figure 2-25.) Cisco MDS 9500 Series Hardware Installation Guide 2-47...
  • Page 128 To install a crossbar module in the Cisco MDS 9513 Director, follow these steps: Before installing any modules, install at least one Supervisor-2 module. Step 1 Cisco MDS 9500 Series Hardware Installation Guide 2-48 Captive Screws and Ejector Levers on the Crossbar Module...
  • Page 129 The ejector levers are completely closed when they are flush with the front of the module. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Figure Installing the Crossbar Module Cisco MDS 9500 Series Hardware Installation Guide 2-26.) 2-49...
  • Page 130: Maintaining A Caching Services Module

    The batteries are automatically charged on a periodic basis with an SMBus-compliant Level III smart charger located on the CSM. The smart charger measures the charge and recharges the battery to full if it is less than 90 percent of capacity. Cisco MDS 9500 Series Hardware Installation Guide 2-50 Chapter 2...
  • Page 131: Maintaining The Disk Drives On The Caching Services Module

    Use both hands to install and remove power supplies. Each DC power supply for the Cisco MDS 9500 Series weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg). You can replace the faulty power supply while the system is operating if the other power supply is Note functioning.
  • Page 132: Removing And Installing The Power Supplies On The Cisco Mds 9513 Director

    Cable retention device Step 4 Loosen all four 6-32 panel fasteners at the corners of the power supply. Cisco MDS 9500 Series Hardware Installation Guide 2-52 Cable Retention Device on the 6000W Power Supply Chapter 2 Installing the Cisco MDS 9500 Series...
  • Page 133 OL-19587-01 2-28.) Handling a Power Supply for the Cisco MDS 9513 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-53...
  • Page 134: Installing An Ac Power Supply In The Cisco Mds 9513 Director

    Step 3 Ensure that the power switch is in the off (0) position on the power supply you are installing. (See Figure 2-29.) Cisco MDS 9500 Series Hardware Installation Guide 2-54 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding” section...
  • Page 135 FANs OK LED is green. • OUTPUT FAIL LED is off. • OL-19587-01 AC Power Supply for the Cisco MDS 9513 Director 2 Power cable retainer Removing and Installing a Power Supply or PEM Cisco MDS 9500 Series Hardware Installation Guide 2-55...
  • Page 136: Removing An Ac Power Supply From The Cisco Mds 9509 Director

    Note power supply. Step 4 Loosen the captive screw. Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series AC power Caution supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg). Step 5 Grasp the power supply handle with one hand, and slide the power supply partially out of the chassis.
  • Page 137: Installing An Ac Power Supply In The Cisco Mds 9509 Director

    If a filler panel is installed, remove the filler panel from the power supply bay by loosening the captive Step 2 screw. OL-19587-01 Handling a Power Supply for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM “System Grounding” section 2-57...
  • Page 138 Figure 2-33 Figure 2-31 1 AC power connection 2 Power supply LEDs 3 Captive screw Cisco MDS 9500 Series Hardware Installation Guide 2-58 Figure 2-31 for the location of the switch. 4000-W AC Power Supply for the Cisco MDS 9509 Director...
  • Page 139 Figure 2-32 3000-W AC Power Supply for the Cisco MDS 9509 Director 1 AC power connection 2 Power cable 3 Power supply switch OL-19587-01 4 Power supply LEDs 5 Captive screws Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-59...
  • Page 140 If the LEDs indicate a power problem, see the Cisco MDS 9000 Family Troubleshooting Guide. If you cannot resolve an issue, contact your customer service representative. Cisco MDS 9500 Series Hardware Installation Guide 2-60 2500-W AC Power Supply for the Cisco MDS 9509 Director...
  • Page 141: Removing A Dc Power Supply From The Cisco Mds 9509 Director

    (DC-I). Loosen the captive screw on the power supply. Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 OL-19587-01 Removing and Installing a Power Supply or PEM Cisco MDS 9500 Series Hardware Installation Guide 2-61...
  • Page 142: Installing A Dc Power Supply In The Cisco Mds 9509 Director

    1 Terminal block cover 2 Power supply LEDs 3 Captive screw Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series DC power Caution supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg).
  • Page 143 Verify power supply operation by checking that the power supply LEDs are in the following states: • INPUT OK LED is green. FAN OK LED is green. • Output fail LED is off. • OL-19587-01 Removing and Installing a Power Supply or PEM “System Grounding” section Cisco MDS 9500 Series Hardware Installation Guide 2-63...
  • Page 144: Removing And Installing The Pems On The Cisco Mds 9506 Director

    Step 3 Remove the cables from the DC PEM by removing the terminal block screws, and then removing the ring lugs from the screws. See Cisco MDS 9500 Series Hardware Installation Guide 2-64 Chapter 2 “Connecting the Power Supplies” section Figure 2-35 for the location of the terminal block screws.
  • Page 145 If the PEM bay is to remain empty, install a PEM filler panel over the opening and tighten the captive screws to 8 in-lb. OL-19587-01 Connecting or Disconnecting the DC PEM 4 Stripped portion of positive cable 5 Insulated portion of negative cable Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-65...
  • Page 146: Installing An Ac Pem

    INPUT OK LED is green. • • FAN OK LED is green. Cisco MDS 9500 Series Hardware Installation Guide 2-66 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding” section “Providing Power to an AC Power Supply for the Cisco 2-30.
  • Page 147: Removing An Ac Or Dc Power Supply From The Cisco Mds 9506 Director

    OL-19587-01 Figure 2-36 Handling a Power Supply for the Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM “Removing a DC PEM” section on page and slide the power supply completely out of 2-64.
  • Page 148: Removing And Installing Fan Modules

    You need a flat-blade or number 2 Phillips screwdriver to perform these procedures. Because the fan modules are located on the left side of the Cisco MDS 9500 Series, Cisco recommends Note guiding the cables for the system out of the right side of the chassis.
  • Page 149: Removing A Front Fan Module On The Cisco Mds 9513 Director

    Grasp the fan module with both hands and pull it outward; rock it gently, if necessary, to unseat the power Step 2 connector from the backplane. Step 3 Pull the fan module clear of the chassis. (See OL-19587-01 Removing and Installing Fan Modules Figure 2-37.) Cisco MDS 9500 Series Hardware Installation Guide 2-69...
  • Page 150: Installing A Front Fan Module On The Cisco Mds 9513 Director

    Verify that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this Step 4 occurs, contact your customer service representative for a replacement part. Cisco MDS 9500 Series Hardware Installation Guide 2-70 Removing the Fan Module for the Cisco MDS 9513 Director...
  • Page 151: Removing The Crossbar Module Fan Tray

    Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing the Crossbar Module Fan Tray...
  • Page 152: Installing The Crossbar Module Fan Tray

    Slide the module carefully into the slot until the the fan tray is fully inserted into the chassis. Tighten the two captive screws on the crossbar module fan tray to 8 in-lb screws. Cisco MDS 9500 Series Hardware Installation Guide 2-72...
  • Page 153: Removing A Front Fan Module On The Cisco Mds 9509 Director

    OL-19587-01 Handling the Fan Module for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Fan Modules Figure 2-39) by turning them counterclockwise;...
  • Page 154: Removing A Front Fan Module On The Cisco Mds 9506 Director

    If you purchased this product through a Cisco reseller, contact the reseller directly for technical Note support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing a Front Fan Module on the Cisco MDS 9506 Director...
  • Page 155: Removing And Installing Compactflash Cards

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing and Installing CompactFlash Cards The supervisor module has one slot for an optional CompactFlash card.
  • Page 156: Installing A Compactflash Card

    Removing and Installing Clock Modules The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of the chassis. In the unlikely event of a clock module failure, Cisco recommends that the failed clock module be replaced during a maintenance window.
  • Page 157: Removing A Clock Module From The Cisco Mds 9513 Director

    Figure 2-40 shows the clock modules in a rear view of the Cisco Clock Module Location on the Cisco MDS 9513 Director (Rear View) Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Clock B (CLK B)
  • Page 158 Step 4 Figure 2-41 Sheet metal side Step 5 Repeat Step 3 Cisco MDS 9500 Series Hardware Installation Guide 2-78 Clock Module Replacement on the Cisco MDS 9513 Director (Rear View) Component side Step 4 to remove any additional clock modules.
  • Page 159: Installing A Clock Module Into The Cisco Mds 9513 Director

    FAN OK LED is green. OL-19587-01 Clock Module for the Cisco MDS 9513 Director through Step 4 to install any additional clock modules. Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Figure 2-42). “Connecting the Power Supplies” section on 2-79...
  • Page 160: Removing A Clock Module From The Cisco Mds 9509 Director

    Figure 2-43 shows the clock modules in a rear view of the Cisco MDS 9509 Director with the back panel removed. Cisco MDS 9500 Series Hardware Installation Guide 2-80 Contents of Cisco MDS 9509 Clock Module Replacement Kits Chapter 2...
  • Page 161 OL-19587-01 Clock Module Location on the Cisco MDS 9509 Director (Rear View) 2-33. Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Clock B (CLK B) “Providing Power to a DC Power Supply in...
  • Page 162 Disconnect and gently remove the module, placing it on an antistatic mat or foam. Step 4 Repeat Step 3 Step 5 Cisco MDS 9500 Series Hardware Installation Guide 2-82 Clock Module Replacement on the Cisco MDS 9509 Director (Rear View) Connectors Connectors Step 4 to remove any additional clock modules.
  • Page 163: Installing A Clock Module Into The Cisco Mds 9509 Director

    Step 4 to install any additional clock modules. Contents of Cisco MDS 9506 Clock Module Replacement Kit Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules “Connecting the Power Supplies” section on Table 2-7 lists the contents of the...
  • Page 164 Clock module Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal components. Cisco MDS 9500 Series Hardware Installation Guide 2-84 Clock Module Location on the Cisco MDS 9506 Director (Rear View) Chapter 2...
  • Page 165 OL-19587-01 Clock Module Replacement on the Cisco MDS 9506 Director (Rear View) Connector Clock module Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules “Removing a DC PEM” section on page Figure 2-46). 2-64.
  • Page 166: Installing A Clock Module Into The Cisco Mds 9506 Director

    INPUT OK LED is green. • • FAN OK LED is green. • OUTPUT FAIL LED is off. Cisco MDS 9500 Series Hardware Installation Guide 2-86 Chapter 2 Installing the Cisco MDS 9500 Series “Connecting the Power Supplies” section on page 2-28.
  • Page 167 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Connecting the Cisco MDS 9500 Series The Cisco MDS 9500 Series provides the following types of ports: •...
  • Page 168: Connecting The Cisco Mds 9500 Series

    Preparing for Network Connections When preparing your site for network connections to the Cisco MDS 9500 Series, consider the following for each type of interface, and gather all the required equipment before connecting the ports: •...
  • Page 169 Procomm Plus—makes communication between the switch and computer possible during setup and configuration. OL-19587-01 Connecting to the Console Port on the Supervisor Module for the Cisco MDS 9500 Series C o n s o le Cisco MDS 9500 Series Hardware Installation Guide Connecting to the Console Port...
  • Page 170: Connecting To The Com1 Port

    Switches running Cisco MDS SAN-OS Release 1.2(1a) or later NX-OS Release 4.1(1b) or later support Note the connection of a COM1 port to a modem. Cisco MDS 9500 Series Hardware Installation Guide Chapter 3 Connecting the Cisco MDS 9500 Series Figure 3-2).
  • Page 171 Connect the adapters using the RJ-45 to RJ-45 rollover cable (or equivalent crossover cable). OL-19587-01 Connecting to the COM1 Port on the Supervisor Module for the Cisco MDS 9500 Series Cisco MDS 9500 Series Hardware Installation Guide Connecting to the COM1 Port...
  • Page 172: Connecting To The Mgmt 10/100/1000 Ethernet Port

    10/100/1000”) and has an RJ-45 interface. (See the switch by IP address, such as through Cisco Fabric Manager. Figure 3-3 Cisco MDS 9500 Series Hardware Installation Guide Figure Connecting to the MGMT 10/100/1000 Ethernet Port on the Supervisor-2 Module for...
  • Page 173: Connecting To The Mgmt 10/100 Ethernet Port

    10/100”) and has an RJ-45 interface. (See switch by IP address, such as through Cisco Fabric Manager. OL-19587-01 Connecting to the MGMT 10/100 Ethernet Port Figure 3-4.) You can use this port to access and manage the Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 174 IP address. This process requires an Ethernet connection to the newly activated supervisor module. Cisco MDS 9500 Series Hardware Installation Guide Connecting to the MGMT 10/100 Ethernet Port on the Supervisor-1 Module for the Cisco MDS 9500 Series...
  • Page 175: Connecting To A Fibre Channel Port

    For instructions specific to the transceiver type, see “X2 Transceiver Specifications” section on page OL-19587-01 Connecting to a Fibre Channel Port Table C-19 on page C-20 on the Cisco MDS 9200 Series. Each C-19. Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 176 Transmit optical bore Receive optical bore Latching sleeve (retracted) EMI gasket Transceiver heat sink Cisco MDS 9500 Series Hardware Installation Guide 3-10 Cisco MDS 9000 Family X2 Transceivers Chapter 3 Connecting the Cisco MDS 9500 Series Figure 3-5.)
  • Page 177: Removing An X2 Transceiver

    Step 3 If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end Note of the transceiver. OL-19587-01 Connecting to a Fibre Channel Port Cisco MDS 9500 Series Hardware Installation Guide 3-11...
  • Page 178: Removing And Installing Sfp Transceivers

    Record the cable and port connections for later reference. Press the release latch on the cable, grasp the connector near the connection point, and gently pull the connector from the transceiver. Cisco MDS 9500 Series Hardware Installation Guide 3-12 C-22.
  • Page 179 If another transceiver is not being installed, protect the optical cage by inserting a clean cover. OL-19587-01 3-8). Be careful not to damage the port cage during this process. Alternate Removal Method for Bale Clasp SFP Transceivers Cisco MDS 9500 Series Hardware Installation Guide Connecting to a Fibre Channel Port 3-13...
  • Page 180: Installing An Sfp Transceiver

    If the cable does not remove easily, ensure that any latch present on the cable has been released before continuing. To remove the cable, follow these steps: Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use. Cisco MDS 9500 Series Hardware Installation Guide 3-14 Chapter 3 Connecting the Cisco MDS 9500 Series OL-19587-01...
  • Page 181: Installing A Cable Into An Sfp Transceiver

    Configuration Guide or the Cisco Fabric Manager Fundamentals Configuration Guide. . OL-19587-01 Figure 3-9). Connecting the LC-Type Cable to a Fibre Channel Port LC plug SFP module Connecting to a Fibre Channel Port Cisco MDS 9500 Series Hardware Installation Guide 3-15...
  • Page 182: Maintaining Sfp Transceivers And Fiber-Optic Cables

    • Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco MDS 9500 Series Hardware Installation Guide 3-16 Chapter 3 Connecting the Cisco MDS 9500 Series...
  • Page 183: Appendix

    Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules This appendix describes the tasks associated with readying the MDS 9500 Series to support Generation 3 8-Gbps Fibre Channel switching modules. It presents an overview of the Generation 3 8-Gbps modules, provides usage guidelines for the modules, and describes three procedures for migrating hardware and upgrading software to enable use of these modules in an MDS 9513 Director.
  • Page 184: Usage Guidelines

    MDS 9000 48-port 8-Gbps Fibre Channel module, DS-X9248-96K9 MDS 9000 24-port 8-Gbps Fibre Channel module, DS-X9224-96K9 Cisco MDS 9500 Series Hardware Installation Guide Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Module Support Matrix for the MDS 9513 Director...
  • Page 185: Before You Begin Upgrading The Mds 9513 Director

    4/44-port 8-Gbps Host-Optimized module, follow these steps: Connect a PC to the console port on the active supervisor module and log in to the switch. Step 1 OL-19587-01 Before You Begin Upgrading the MDS 9513 Director Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 186 Cisco Storage Area Networking Operating System (SAN-OS) Software TAC support: http://www.cisco.com/tac Copyright (c) 2002-2006, Cisco Systems, Inc. All rights reserved. The copyrights to certain works contained herein are owned by other third parties and are used and distributed under license.
  • Page 187: Installing Mds 9513 Fabric 2 Modules And Running Cisco San-Os 3.X

    (in slot 7) and its associated fabric module in the Fabric 1 slot. OL-19587-01 Module-Type -------------------------------- ------------------ ------------ Supervisor/Fabric-2 Supervisor/Fabric-2 Migration Procedures for the MDS 9513 Director Model Status DS-X9530-SF2-K9 ha-standby DS-X9530-SF2-K9 active * Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 188 Hold the front edge of the module and slide the module partially out of the slot. Do not touch the module circuitry. Cisco MDS 9500 Series Hardware Installation Guide Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules...
  • Page 189 (See OL-19587-01 Captive Screws and Ejector Levers on the Fabric Module Figure Cisco MDS 9500 Series Hardware Installation Guide Migration Procedures for the MDS 9513 Director Ejector levers Fabric slot 2 label...
  • Page 190 If it does not, check to see if the module is seated correctly in the slot. Step 13 Enter the system switchover command to put the other supervisor in active mode. Cisco MDS 9500 Series Hardware Installation Guide Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Installing a Fabric Module...
  • Page 191: Installing Mds 9513 Fabric 2 Modules And Installing Mds 9000 24-Port Or 48-Port 8-Gbps Modules

    OL-19587-01 Module-Type -------------------------------- ------------------ ------------ Fabric Module 2 Fabric Module 2 World-Wide-Name(s) (WWN) ------ -------------------------------------------------- Migration Procedures for the MDS 9513 Director Model Status DS-13SLT-FAB2 DS-13SLT-FAB2 Serial-Num ---------- JAF1207ARRS JAE1212BPR0 Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 192: Installing The Mds 9513 Fabric 2 Modules And Activating Higher Bandwidth By Reloading The Switch

    MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section on page Step 6 Enter the show hardware fabric-mode command to display information about Generation 3 module support. Cisco MDS 9500 Series Hardware Installation Guide A-10 Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules A-11.
  • Page 193: Installing The Mds 9513 Fabric 2 Modules And Activating Higher Bandwidth By Powering Down The Switch

    Power up the switch by turning the power supply switch at the rear of the power supply clockwise to the Step 7 on position on both power supplies. OL-19587-01 “Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section Cisco MDS 9500 Series Hardware Installation Guide Migration Procedures for the MDS 9513 Director A-11...
  • Page 194: Migration Procedure For The Mds 9509 Director And Mds 9506 Director

    4.1(0.182) MAC-Address(es) -------------------------------------- 00-19-56-be-65-d0 to 00-19-56-be-65-d8 00-0c-30-0d-2b-b8 to 00-0c-30-0d-2b-bc 00-05-30-00-52-f2 to 00-05-30-00-52-f6 Cisco MDS 9500 Series Hardware Installation Guide A-12 Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Module-Type -------------------------------- ------------------ ------------ 4x1GE IPS, 18x1/2/4Gbps FC Modul DS-X9304-18K9...
  • Page 195 OL-19587-01 Migration Procedure for the MDS 9509 Director and MDS 9506 Director 2-40. Refer to the Migrating from Supervisor-1 Modules to Supervisor-2 Modules Cisco MDS 9500 Series Hardware Installation Guide 2-39. If the switch has Supervisor-2 modules “Installing Supervisor Modules”...
  • Page 196 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 197: Appendix

    B-6. OL-19587-01 A P P E N D I X and the “Requirements Specific to Solid-Walled B-4. “Requirements Specific to Two-Post Telco Racks” section Cisco MDS 9500 Series Hardware Installation Guide F (0 to 40 “Requirements Specific to...
  • Page 198: Cabinet And Rack Requirements For The Cisco Mds 9513 Chassis

    Optional jumper power cords are available for use in a cabinet. See the Note page D-11. Cisco MDS 9500 Series Hardware Installation Guide “Installing the Cisco MDS 9513 Director in a Rack” section 2-7. Appendix B Cabinet and Rack Installation “Jumper Power Cord”...
  • Page 199: Appendix B Cabinet And Rack Installation

    Cisco recommends that the roof should be perforated with at least a 20 percent open area. • Cisco recommends an open or perforated cabinet floor to enhance cooling. • OL-19587-01 “General Requirements for Cabinets and Racks” section on Chassis. Cisco MDS 9500 Series Hardware Installation Guide Cabinet and Rack Requirements Perforated Cabinet Requirements...
  • Page 200: Requirements Specific To Solid-Walled Cabinets

    The solid-walled cabinet requirements for the Cisco MDS 9513 chassis are as follows: • Perforated front and back doors and solid or open side panels. Cisco MDS 9500 Series Hardware Installation Guide B-1, solid-walled cabinets must meet the following requirements: Appendix B Cabinet and Rack Installation “General Requirements for Cabinets and...
  • Page 201: Solid-Walled Cabinet Requirements For The Cisco Mds 9509 And The Cisco Mds 9506 Chassis

    Director only, and can be removed or left installed once the front rack-mount brackets are securely fastened to the rack-mounting rails. The Cisco MDS 9506 Director does not require shelf brackets. Note OL-19587-01 Cabinet and Rack Requirements “General Requirements for Cabinets and Racks” section on Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 202: Requirements Specific To Two-Post Telco Racks

    • This optional kit is not provided with the switch; to order the kit, contact your switch supplier. Note Cisco MDS 9500 Series Hardware Installation Guide Appendix B Cabinet and Rack Installation “General Requirements for Cabinets and Racks” section on...
  • Page 203: Rack-Mounting Guidelines

    Support rack-mount bracket Rack-mount support brace 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket B-1. This is particularly important to MDS 9222i...
  • Page 204: Before Installing The Shelf Brackets

    You need the following equipment for this installation: • Number 2 Phillips screwdriver Tape measure and level (to ensure shelf brackets are level) • Cisco MDS 9500 Series Hardware Installation Guide Contents of Shelf Bracket Kit Part Description Slider brackets Shelf brackets Crossbar 10-32 x 3/8-in.
  • Page 205: Installing The Shelf Bracket Kit Into A Two-Post Telco Rack

    Installing the Shelf Bracket Kit into a Two-Post Telco Rack 3 10-32 screws (2x) 4 Crossbar Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket Figure B-1. Align the screw holes at the Figure B-1, using the 10-32 screws.
  • Page 206: Installing The Shelf Bracket Kit Into A Four-Post Eia Rack

    Step 2 Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired). Cisco MDS 9500 Series Hardware Installation Guide B-10 Installing the Shelf Bracket Kit into an EIA Rack 4 Crossbar...
  • Page 207: Installing The Switch On The Rack-Mount Support Brackets

    M4 holes on the chassis for attaching a grounding lug. OL-19587-01 2-6. 2-6. Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket Figure B-2, using the 10-32 screws.
  • Page 208: Installing The Switch On The Shelf Brackets

    Removing the Shelf Bracket Kit (Optional) The shelf bracket kit can be removed once the Cisco MDS 9500 Series has been installed in a two-post telco or four-post EIA rack, and the front rack-mount brackets are securely attached to the rack-mounting rails.
  • Page 209: Cisco Mds 9500 Shelf Bracket

    Installing the Cisco MDS 9500 Shelf Bracket Kit into a Cabinet or Rack, page B-15 • Installing the Switch on the Shelf Brackets, page B-16 OL-19587-01 B-1. Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9500 Shelf Bracket “Cabinet and Rack Requirements” B-13...
  • Page 210 Number 2 Phillips screwdriver • Tape measure and level (to ensure shelf brackets are level) • Cisco MDS 9500 Series Hardware Installation Guide B-14 “Cabinet and Rack Requirements” section on page Appendix C, “Technical Specifications.” Contents of Cisco MDS 9500 Shelf Bracket Kit...
  • Page 211 Verify that the shelf brackets are at the same height (using the level or tape measure as desired). Step 4 OL-19587-01 Installing the Shelf Bracket Kit into a Rack Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9500 Shelf Bracket Figure B-3. Align the screw holes at...
  • Page 212 Caution We recommend grounding the chassis, although the rack is already grounded. There is a grounding pad with two threaded M4 holes on the chassis for attaching a grounding lug. Cisco MDS 9500 Series Hardware Installation Guide B-16 Appendix B Cabinet and Rack Installation “Installing the Chassis in a Cabinet or Rack”...
  • Page 213: Appendix

    Specifications for cables and connectors are provided in Switch Specifications The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per minute) of airflow per slot with 410 W of power dissipation per slot. Table C-1 lists the environmental specifications for the Cisco MDS 9500 Series.
  • Page 214 Table C-3 Description Dimensions (HxWxD) Weight Cisco MDS 9500 Series Hardware Installation Guide Physical Specifications for the Cisco MDS 9513 Director Specification 24.5 x 17.5 x 28 in. (62.2 x 44.5 x 71.1 cm) Chassis requires 14 RU , 15 RU with a rack-mount kit.
  • Page 215 Chassis configured with two supervisor modules, fan module, and two power supplies: 86 lb (39 kg). System fan tray: 7.70 lbs (3.49 kg) 1900W AC power supply: 11 lbs (4.99 kg) Cisco MDS 9500 Series Hardware Installation Guide Switch Specifications per supervisor,...
  • Page 216: Module Specifications

    1. RU = rack unit; 1 RU = 1.75 in. (4.45 cm) 2. lfm = linear feet per minute 3. cfm = cubic feet per minute Module Specifications Table C-5 lists the specifications for the Cisco MDS 9500 Series supervisor modules, services modules, and switching modules. Table C-5 Description Environmental Requirements Temperature, certified for operation 32 to 104°F (0 to 40°C)
  • Page 217: Module Specifications C

    MPS-14/2 Supervisor-2 for MDS 9500 Series Supervisor-1 for MDS 9500 Series Supervisor for MDS 9200 Series OL-19587-01 Cisco MDS 9500 Series Module Specifications (continued) Specification 1.75 x15.5 x16.5 in. (4.4 x 39.4 x 41.9 cm) Note These are the maximum...
  • Page 218: Power Specifications For The Cisco Mds 9513 Director

    • • One AC power connection @110 VAC and one AC power connection @ 220 VAC = 2900 W output Cisco MDS 9500 Series Hardware Installation Guide Weight of Modules in the Cisco MDS 9000 Family (continued) Weight 2.25 lb (1.13 kg) 0.50 lb (0.25 kg)
  • Page 219 @ 220 VAC = 2900 W output Two AC power connection @ 220 VAC = 6000 W output Table C-9 Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9513 Director is based on worst-case conditions. Typical numbers...
  • Page 220 16-port Storage Services Node, DS-X9316-SSNK9 AC Power Consumption for the Cisco MDS 9513 Director Table C-10 shows the typical AC power consumption for a Cisco MDS 9513 Director. Cisco MDS 9500 Series Hardware Installation Guide Power Heat NX-OS SAN-OS Required...
  • Page 221: Power Specifications For The Cisco Mds 9509 Director

    Typical AC Power Consumption for a Cisco MDS 9513 Director Specifications for Cisco MDS 9509 Power Supplies Specification Autoranging input with power factor corrector. 100 to 240 VAC (±10%). Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Typical AC Power Consumption (Watts)
  • Page 222 Voltage Current rating Frequency Output capacity Output voltage at 200/240 Cisco MDS 9500 Series Hardware Installation Guide C-10 Specifications for Cisco MDS 9509 Power Supplies (continued) Specification 16 A maximum at 100 to 120 VAC and 1300-W output. 16 A maximum at 200 to 240 VAC and 2500-W output.
  • Page 223 2.x and — — 2.x and — — 2.x and Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Table C-13 is based on worst-case conditions. Input Current 90 VAC 120 VAC 180 VAC...
  • Page 224 DS-X9032-SMV DS-X9560-SMC 48-port 8-Gbps switching module, DS-X9248-96K9 24-port 8-Gbps switching module, DS-X9224-96K 4/44-port 8-Gbps Host-Optimized switching module, DS-X9248-48K9 16-port Storage Services Node, DS-X9316-SSNK9 Cisco MDS 9500 Series Hardware Installation Guide C-12 Power Heat NX-OS SAN-OS Required Dissipation Release Release (watts) (BTU/hr) 2.x and...
  • Page 225 2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Input Current Heat Dissipation 48 VDC 60 VDC...
  • Page 226: Power Specifications For The Cisco Mds 9506 Director

    Component Power Requirements and Heat Dissipation for the Cisco MDS 9506 Director, page C-16 • AC Power Consumption for the Cisco MDS 9506 Director, page C-19 • Cisco MDS 9500 Series Hardware Installation Guide C-14 Typical AC Power Consumption for a Cisco MDS 9509 Director Appendix C...
  • Page 227 1900 W maximum (at input of -48 to -60 VDC). 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 37.4 A. Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9506 Director...
  • Page 228 12-port 4-Gbps switching module, DS-X9112 4-port 10-Gbps switching module, DS-X9704 32-port 1-Gbps/2-Gbps Fibre Channel module DS-X9032 Cisco MDS 9500 Series Hardware Installation Guide C-16 Table C-17 list the AC and DC power requirements and heat dissipation for the Table C-16 Power Heat...
  • Page 229 2.x and 1260 1200 2.x and 1260 2.x and 1273 1163 4.2(1) 1273 Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9506 Director Input Current 90 VAC 120 VAC 180 VAC (amps) (amps) (amps) 2.92 2.19...
  • Page 230 DS-X9304-SMIP 2.x and 1.x 32-port SSM DS-X9032-SSM 2.x and 1.x 32-port ASM DS-X9032-SMV 2.x and 1.x DS-X9560-SMC 2.x and 1.x Cisco MDS 9500 Series Hardware Installation Guide C-18 Power Heat Input Current Required Dissipation (watts) (BTU/hr) 48 VDC (amps) 3.50 3.50...
  • Page 231: Ac Power Consumption For The Cisco Mds 9506 Director

    Use only Cisco X2 transceivers on the Cisco MDS 9500 Series Switches. Each Cisco X2 transceiver is encoded with the model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.
  • Page 232: Cisco 10-Gbps Fibre Channel X2 Transceivers

    Cisco 10-Gbps Fibre Channel X2 transceivers. Table C-21 DS-X2-FC10G-SR DS-X2-FC10G-LR DS-X2-FC10G-ER Cisco MDS 9500 Series Hardware Installation Guide C-20 Cisco 10-Gbps Fibre Channel X2 Transceivers Description 10-Gbps Fibre Channel SR, X2, SC 10-Gbps Fibre Channel LR, X2, SC...
  • Page 233: Cisco 10-Gbps Ethernet X2 Transceivers

    Cisco 10-Gbps Ethernet X2 Transceivers Description 10-Gbps Ethernet Short Reach, X2, SC General Specifications for the Cisco 10-Gbps Ethernet X2 Transceivers Wavelength (nanometer) Fiber Type Cisco MDS 9500 Series Hardware Installation Guide X2 Transceiver Specifications Table C-21. Storage Maximum Minimum 85°C...
  • Page 234: Environmental And Power Requirements Specifications For Cisco 10-Gbps Ethernet X2 Transceiver

    SFP and SFP+ Transceiver Specifications The Cisco MDS 9500 Series is compatible with SFP and SFP+ transceivers and cables that have LC connectors. The wavelength of each transceiver must match the transceiver on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications.
  • Page 235: Cisco Fibre Channel Sfp And Sfp+ Transceivers

    S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Use only Cisco SFP transceivers on the Cisco MDS 9500 Series. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.
  • Page 236: General Specifications For Cisco 8-Gbps Fibre Channel Sfp+ Transceivers

    Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Table C-29 provides the power specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers. Table C-29 DS-SFP-FC8G-SW -1.3 Cisco MDS 9500 Series Hardware Installation Guide C-24 General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Wavelength Core Size...
  • Page 237 Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Operating Maximum Minimum 40°C 0°C 40°C 0°C Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Fiber Loss Budget (dBm) Minimum 2.10 (2 2.62 (2 Gbps) Gbps) 1.78 (4 2.06 (4...
  • Page 238: General Specifications For Cisco 4-Gbps Fibre Channel Sfp Transceivers

    Cisco 4-Gbps Fibre Channel SFP transceivers. Table C-32 DS-SFP-FC4G-SW -2.5 DS-SFP-FC4G-MR -3 DS-SFP-FC4G-LW -3 Cisco MDS 9500 Series Hardware Installation Guide C-26 General Specifications for Cisco 4-Gbps Fibre Channel SFP Transceivers Wavelength Core Size...
  • Page 239: General Specifications For Cisco 2-Gbps Fibre Channel Sfp Transceivers

    1310 Power Requirement Specification for Cisco 2-Gbps Fibre Channel SFP Transceivers Average Transmit Power (dBm) Maximum Minimum -2.5 -10.0 -11.7 Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Storage Maximum Minimum 85°C -40°C 85°C -40°C 85°C -40°C...
  • Page 240: Maximum Environmental And Electrical Ratings For Cisco Fibre Channel Sfp Transceivers

    Table C-38 lists the combination Fibre Channel/Gigabit Ethernet SFP transceivers. Table C-38 Transceiver Module Product Number DS-SFP-FCGE-LW DS-SFP-FCGE-SW Cisco MDS 9500 Series Hardware Installation Guide C-28 Environmental Specifications for Cisco 2-Gbps Fibre Channel SFP Transceivers Operating Maximum Minimum 40°C 0°C 40°C...
  • Page 241: General Specifications For Cisco Fibre Channel And Gigabit Ethernet Sfp Transceivers

    Power (dBm) Power (dBm) Maximum Minimum Maximum -1.2 -10.0 (FC) -9.5 (GE) -11.0 Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Baud Rate Cable Distance (GBd) (meter) 1.0625 300 m (984 ft) 2.125 150 m (492 ft) 1.0625...
  • Page 242: Cisco Cwdm Sfp Transceivers

    Cisco CWDM SFP 1570 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Cisco CWDM SFP 1590 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Cisco CWDM SFP 1610 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Cisco MDS 9500 Series Hardware Installation Guide C-30 Environmental Specifications for Cisco Fibre Channel and Gigabit Ethernet SFP...
  • Page 243: Environmental And Optical Specifications For Cisco 2-Gbps Cwdm Sfp Transceivers

    Transceivers OL-19587-01 Cisco 4-Gbps CWDM SFP Transceivers Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers Operating Maximum Minimum 40°C 0°C Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Color Gray Violet Blue Green Yellow Orange Brown...
  • Page 244 For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. Cisco MDS 9500 Series Hardware Installation Guide C-32 Optical Specification for Cisco 2-Gbps CWDM SFP Transceivers...
  • Page 245: Environmental And Optical Specifications For Cisco 4-Gbps Cwdm Sfp Transceivers

    – -15.7 – – 17.8 – λ 1450 – – – – – Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Storage Maximum Minimum 85°C -40°C Maximum Units Notes/Conditions Available center wavelengths are 1470, 1490, 1510, 1530,...
  • Page 246: Cisco Gigabit Ethernet Transceivers

    Table C-50 DS-SFP-GE-T For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. Cisco MDS 9500 Series Hardware Installation Guide C-34 Cisco Gigabit Ethernet SFP Transceivers Description 1-Gbps Ethernet SFP...
  • Page 247: Cisco Dwdm Sfp Transceivers

    A single Cisco MDS 9000 family switching module supports up to eight 2-Gbps DWDM SFPs. For more information, refer to the data sheet at: http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6576/product_data_sheet0900aecd805 82763.html. OL-19587-01 SFP and SFP+ Transceiver Specifications Cisco MDS 9500 Series Hardware Installation Guide C-35...
  • Page 248 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 249: Appendix

    MGMT 10/100 Ethernet Port, page D-6 • Supported Power Cords and Plugs, page D-7 • Cables and Adapters Provided The Cisco MDS 9500 Series accessory kit includes the following items: • RJ-45 rollover cable DB-9F/RJ-45F PC—RJ-45 to DB-9 female DTE adapter (labeled “Terminal”) •...
  • Page 250: Console Port

    RJ-45/DSUB F/F adapter or the DB-9F/RJ-45F PC terminal adapter to connect the console port to a computer running terminal emulation software. Console Port Pinouts Table D-1 lists the pinouts for the console port on the Cisco MDS 9500 Series. Table D-1 Signal 1. Pin 1 is connected internally to pin 8.
  • Page 251: Connecting The Console Port To A Computer Using The Db-9 Adapter

    COM1 Port Pinouts Table D-4 lists the pinouts for the COM1 port on the Cisco MDS 9500 Series. Note Additional cables and adapters can be ordered from your customer service representative.
  • Page 252: Connecting The Com1 Port To A Modem

    RJ-45, straight-through UTP cable to connect the management port to an external hub, switch, or router (see Figure D-1 1 Pin 1 Cisco MDS 9500 Series Hardware Installation Guide COM1 Port Pinouts (continued) Port Mode Signaling and Pinouts for Modem with DB-25 Connection DB-9F/RJ45F...
  • Page 253 8 NC OL-19587-01 10/100/1000BASE-T Management Port Cable Pinout (MDI) Twisted-Pair 10/100/1000BASE-T Cable Schematic Switch/Hub 1 RXD+ 2 RXD- 3 TXD+ 6 TXD- 4 NC 5 NC 7 NC 8 NC Cisco MDS 9500 Series Hardware Installation Guide MGMT 10/100/1000 Ethernet Port...
  • Page 254: Mgmt 10/100 Ethernet Port

    Table D-7 Signal RD– Not used Not used Not used Not used Cisco MDS 9500 Series Hardware Installation Guide RJ-45 Interface Cable Connector RJ-45 (both ends) 2 Pin 8 10/100BASE-T Management Port Cable Pinout (MDI) Appendix D Cable and Port Specifications...
  • Page 255: Supported Power Cords And Plugs

    Only the regular power cords or jumper power cords provided with the switch are supported. Note Table D-8 lists the power cords for the Cisco MDS 9500 Series switches and provides their lengths in feet and meters. Table D-8 Description...
  • Page 256 Power Cord, 250VAC 13A KSC8305 Plug, Korea Power Cord, 250VAC 15A CNS10917-2 Plug, Taiwan Cabinet Jumper Power Cord, 250VAC 16A C20-C19 Connectors Cisco MDS 9500 Series Hardware Installation Guide Power Cords for the MDS 9500 Series Switches (continued) Appendix D Cable and Port Specifications Length Feet Meters 13.65...
  • Page 257: Supported Plugs For 6000-W Ac, 2500-W Ac, And 1900-W Ac Power Supplies

    (6000 W, 3000 W, 2500 W, and 1900 W) 23 G SEV 1011 (16 A) 6 South Africa (6000 W, 3000 W, 2500 W, and 1900 W) EL 208, SABS 164-1 (16 A) Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs...
  • Page 258 Figure D-7 1 NEMA 5-20P North American power cord product ID: CAB-7513AC 110 VAC (20 A) Cisco MDS 9500 Series Hardware Installation Guide D-10 Additional Power Supply Plug Supported for 1900-W Only Figure D-7 at 110 VAC results in 1300 W available to the system.
  • Page 259: Supported Plugs For The 4000-W Ac Power Supply

    C19 and C20 connectors on the optional jumper power cord for the Cisco MDS 9500 Series. The C19 connector plugs into the C20 inlet on the Cisco MDS 9500 Series power supply, while the C20 connector plugs into the C19 receptacle of a power distribution unit for a cabinet.
  • Page 260: Power Supply Ac Power Cords

    Locale North America/Japan US/Japan Australia China Switzerland Continental Europe Cabinet Jumper Power Cord Cisco MDS 9500 Series Hardware Installation Guide D-12 Power Supply AC Power Cords Power Cord Part Number Source Plug Type CAB-9K2A-NA NEMA 5-20 CAB-9K16A-US2 NMEA L6-20 CAB-9K16A-AUS...
  • Page 261: Ac Power Cord Illustrations

    Length: 14 ft 0 in. (4.26 m) CAB-9K16A-US2 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: IEC 60320 C19 Connector: IEC 60320 C19...
  • Page 262 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Figure D-12 Plug: AU20S3 Figure D-13 Figure D-14 Plug: SEV 5934-2 Cisco MDS 9500 Series Hardware Installation Guide D-14 CAB-9K16A-AUS Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) CAB-9K16A-CH...
  • Page 263 CAB-9K16A-EU Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) CAB-C19-CBN Plug: IEC 60320 C20 Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: IEC 60320 C15 Connector: IEC 60320 C19 D-15...
  • Page 264 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
  • Page 265: Appendix

    If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you Note purchased support directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm OL-19587-01 A P P E N D I X “Finding the Chassis Serial Number” section on page Cisco MDS 9500 Series Hardware Installation Guide E-2.
  • Page 266: Finding The Chassis Serial Number

    In later releases of the Cisco MDS 9509 Director, the chassis serial number label was moved, as shown Figure E-2. Earlier releases may have the serial number label on the right side instead of the left. Cisco MDS 9500 Series Hardware Installation Guide OL-19587-01...
  • Page 267 The Cisco MDS 9506 Director chassis serial number label is shown in Figure E-3 SN: AAANNNNXXXX OL-19587-01 Serial Number Location on Cisco MDS 9509 Director Serial Number Location on Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide Contacting Customer Service Figure E-3.
  • Page 268: Site Preparation Checklist

    Planning the location and layout of your equipment rack or wiring closet is essential for successful switch operation, ventilation, and accessibility. recommends completing before installing the Cisco MDS 9500 Series. Consider heat dissipation when sizing the air-conditioning requirements for an installation. See Table C-1 on page C-1 MDS 9513 Director”...
  • Page 269 4. RFI = radio frequency interference OL-19587-01 Site Planning Checklist (continued) Verified By Cable type Connector type Cable distance limitations Interface equipment (transceivers) evaluation: Distance limitations for signaling Site wiring levels Cisco MDS 9500 Series Hardware Installation Guide Site Preparation Checklist Time Date...
  • Page 270: Contact And Site Information

    Floor location Address (line 1) Address (line 2) City State Zip code Country Cisco MDS 9500 Series Hardware Installation Guide (Table E-2) to record contact and site information. Contact and Site Information Appendix E Site Planning and Maintenance Records OL-19587-01...
  • Page 271: Chassis And Module Information

    Modem telephone number Table E-4 Slot Module Type Supervisor OL-19587-01 (Table E-3 Table Network-Related Information Module Information Module Serial Number Cisco MDS 9500 Series Hardware Installation Guide Chassis and Module Information E-4) to record information about the chassis and Notes...
  • Page 272 Slot Module Type Supervisor Slots 7, 8, and 9 are only available in the Cisco MDS 9509 Director. Note Cisco MDS 9500 Series Hardware Installation Guide Module Information (continued) Module Serial Number Appendix E Site Planning and Maintenance Records Notes...
  • Page 273: I N D E X

    (MDS 9509 Director) 2-30, 2-32 providing (MDS 9513 Director) 2-29 removing (MDS 9509 Director) 2-56 removing (MDS 9513 Director) 2-52 description 1-49 figure 1-49 LEDs (table) 1-50 description ii-xvii description 2-50 downloading 1-49, 1-51 Cisco MDS 9500 Series Hardware Installation Guide IN-1...
  • Page 274 2-26 installing in a rack (procedure) power supplies 2-11 preinstallation Cisco MDS 9500 Series Hardware Installation Guide IN-2 chassis (MDS 9513 Director) Cisco MDS 9500 Series Multilayer Directors Cisco MDS Fabric Switch clock modules COM1 port 2-15...
  • Page 275 2-19 MGMT 10/100 MGMT 10/100/1000 crossbar fan modules, description description 1-16 failure (caution) 1-16 LEDs 1-16 removing and installing 2-68 1-43 3-16 connecting connecting with LC-type cables (figure) Cisco MDS 9500 Series Hardware Installation Guide Index 1-16 1-57 3-15 IN-3...
  • Page 276 (MDS 9506 Director) chassis (MDS 9509 Director) chassis (MDS 9513 Director) CompactFlash cards 2-76 crossbar modules 2-48 Cisco MDS 9500 Series Hardware Installation Guide IN-4 2-19 installing SFP transceivers IPS modules 2-22 2-22 IP Storage Services module. See IPS modules...
  • Page 277 (table) 2-11 2-77, 2-80 open racks, standard (requirements) organization description PEMs installing removing physical specifications (table) pinouts Cisco MDS 9500 Series Hardware Installation Guide A-10 A-12 1-27 1-44, 1-46 1-45, 1-49 2-19 ii-xi ii-xvii 2-64 2-64...
  • Page 278 (MDS 9509 Director) removing (MDS 9513 Director) starting up the switch 2-28 supported plugs Cisco MDS 9500 Series Hardware Installation Guide IN-6 power supplies (Cisco MDS 9506 Director) power supplies (Cisco MDS 9509 Director) power supplies (MDS 9506 Director)
  • Page 279 LEDs 1-51 self-test running LEDs 1-51 1-41 CompactFlash cards 1-22 control and management 1-21 Ethernet port features 1-21 figure 1-21 LEDs 1-23 LEDs (figure) 1-23 LEDs (table) 1-23 Cisco MDS 9500 Series Hardware Installation Guide Index C-16 C-7, IN-7...
  • Page 280: Weight Of Modules C

    1-35 16-port 2-Gbps Fibre Channel (figure) 24-port 4-Gbps Fibre Channel switching modules 1-35 Cisco MDS 9500 Series Hardware Installation Guide IN-8 24-port 8-Gbps Fibre Channel switching modules 32-port 2-Gbps Fibre Channel (figure) 4/44-port 4-Gbps Host-Optimized Fibre Channel switching modules...
  • Page 281 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m description 1-56, C-19 installing 3-11 removing 3-11 supported (table) C-20 Cisco MDS 9500 Series Hardware Installation Guide IN-9 OL-19587-01...
  • Page 282 S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...

Table of Contents