Page 1
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware...
Page 2
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system.
Page 3
Cisco MDS 9506 Power Supplies Fan Modules Supervisor Modules Supervisor-2 Modules OL-19587-01 xvii xvii xviii xxii 1-10 1-12 1-15 1-16 1-16 1-17 Control and Management 1-18 Processor 1-18 C O N T E N T S xxii Cisco MDS 9500 Series Hardware Installation Guide...
LEDs on the Fibre Channel Advanced Services Modules 32-Port Fibre Channel Storage Services Module LEDs on the Storage Services Modules Caching Services Module LEDs on the Caching Services Module Supported Transceivers Cisco MDS 9500 Series Hardware Installation Guide 1-18 1-19 1-21 1-21 1-22...
Page 5
Providing Power to a DC Power Supply in the Cisco MDS 9509 Director Providing Power to a DC Power Supply in the Cisco MDS 9506 Director 2-39 2-40 2-44 1-57 1-57 1-58 2-11 2-15 2-19 2-33 2-34 2-36 2-38 2-45 2-46 2-47 Cisco MDS 9500 Series Hardware Installation Guide Contents 2-29 2-45...
Page 6
Installing a Clock Module into the Cisco MDS 9509 Director Removing a Clock Module from the Cisco MDS 9506 Director Installing a Clock Module into the Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide 2-50 2-50 2-51...
Page 7
Switch A-11 Cabinet and Rack Requirements for the Cisco MDS 9513 Chassis Cabinet and Rack Requirements for the Cisco MDS 9509 and Cisco MDS 9506 Chassis 3-12 3-14 3-14 3-15 3-16 A-12 Cisco MDS 9500 Series Hardware Installation Guide Contents...
Page 8
Specifications for the Cisco MDS 9509 Power Supplies Component Power Requirements and Heat Dissipation for the Cisco MDS 9509 Director AC Power Consumption for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide viii Perforated Cabinet Requirements for the Cisco MDS 9513 Chassis...
Page 10
Contact and Site Information Chassis and Module Information N D E X Cisco MDS 9500 Series Hardware Installation Guide Supported Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies Supported Plugs for the 4000-W AC Power Supply D-11...
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m New and Changed Information The Cisco MDS 9500 Series Hardware Installation Guide applies to Cisco MDS NX-OS Release 4.2(1) and earlier Cisco MDS SAN-OS releases.
Page 12
18/4-port Multiservice (MSM-18/4) module Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 24-port 8-Gbps Fibre Channel switching module. The switching module offers 24 autosensing 1-, 2-, 4- and 8-Gbps Fibre Channel ports and can be used in the Cisco MDS 9500 Series Switches.
Page 13
Crossbar modules X2 transceiver OL-19587-01 Documented Features for the Cisco MDS 9500 Series (continued) Description Added Cisco MDS 9513 Multilayer Director. The chassis consists of 13 horizontal slots, where slots 1 to 6 and slots 9 to 13 are reserved for switching,...
Page 14
(IPS-4) module Jumper power cord Installation Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 4-Gbps Fibre Channel SFP trans- ceiver. Added 3000W power supply for the Cisco MDS 9509 Director.
Page 15
Cisco MDS 9506 Director 16-port Fibre Channel module OL-19587-01 Documented Features for the Cisco MDS 9500 Series (continued) Description 9509 power supplies. Added instructions for installation and removal of SFP transceivers and cables. Added United Kingdom power cable BS89/13, BS 1363/A, for use with 1900-W power supply.
Page 16
Channel module Cisco MDS 9509 Switch Cisco MDS 9500 Series Hardware Installation Guide Documented Features for the Cisco MDS 9500 Series (continued) Description Added 32-port Fibre Channel hot-swappable switching module for use with the Cisco MDS 9500 Series. Added the Cisco MDS 9509 Director, a multilayer Fibre Channel switch that supports up to nine modules.
Appendix C Technical Specifications OL-19587-01 Description Provides an overview of the Cisco MDS 9500 Series and its components. Describes how to install the Cisco MDS 9500 Series, including installing the chassis, modules, CompactFlash card, power supplies, and fan assembly. Describes how to connect the Cisco MDS 9500 Series, including the modules.
Page 18
Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Cisco MDS 9500 Series Hardware Installation Guide xviii Description Lists cable and port specifications for the Cisco MDS 9500 Series switch. Provides a site-planning checklist and sample maintenance and network records. Preface...
Page 19
Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo. Cisco MDS 9500 Series Hardware Installation Guide OL-19587-01...
The Cisco MDS 9500 Series includes the Cisco MDS 9513 Director, the Cisco MDS 9509 Director, and the Cisco MDS 9506 Director, which all provide the following high availability features: Redundant Supervisor-2 modules with associated external crossbar modules for the Cisco MDS •...
Page 24
Services Modules, page 1-41 • Supported Transceivers, page 1-56 • Chassis This section describes the different chassis offerings in the Cisco MDS 9500 Series: • Cisco MDS 9513 Director, page 1-3 Cisco MDS 9509 Director, page 1-6 • Cisco MDS 9506 Director, page 1-7 •...
Two hot-swappable clock modules located at the rear of the chassis. • The Cisco MDS 9513 Director does not support the Advanced Services Module (ASM) or the Caching Note Services Module (CSM). OL-19587-01 “Port Index Availability” section on page 1-28 Cisco MDS 9500 Series Hardware Installation Guide Chassis...
Page 26
The rear of the chassis supports two vertical, redundant power supplies, two clock modules, two vertical, redundant, external crossbar modules, and a variable speed fan tray with two individual fans located above the crossbar modules. (See Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9513 Chassis Front Panel View Figure 1-2.)
Page 27
1. Clock modules are located inside the air vent panel. You must remove the air vent panel to access the clock modules. OL-19587-01 Rear Panel 9513 Chassis Cisco MDS 9500 Series Hardware Installation Guide Air vent panels Clock module Chassis...
Page 28
2 Supervisor module in slot 5 3 Redundant supervisor module in slot 6 4 Switching or services modules in slots 7–9 Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9509 Chassis 5 Fan module 6 Power supply 1 7 ESD socket...
Page 29
Switching or services modules in slots 1–4 Supervisor modules in slots 5 and 6 Fan module OL-19587-01 Cisco MDS 9506 Chassis Cisco MDS 9500 Series Hardware Installation Guide Figure 1-4, and it supports the following: ESD Socket Power supplies (in back) Location of power entry modules (PEMs) -- one PEM shown and one filler panel shown.
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Backplane and Clock Modules The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of the chassis. The Cisco MDS 9513 and 9509 Directors have two field-replaceable clock modules for redundancy and failover.
Reference. Power Supplies The Cisco MDS 9500 Series supports dual hot-swappable power supplies, each of which is capable of supplying sufficient power to the entire chassis should one power supply fail. The power supplies monitor their output voltage and provide status to the supervisor modules. To prevent the unexpected shutdown of an optional module, the power management software only allows a module to power up if adequate power is available.
Page 32
Cisco MDS 9513 Power Supplies The Cisco MDS 9513 Director supports the 6000-W AC power supply (AC input). (See Figure 1-6 Power supply switch AC power connection Cisco MDS 9500 Series Hardware Installation Guide 1-10 Cisco MDS 9513 Power Supply Chapter 1 Product Overview...
Page 33
Green Green Green Green Green Cisco MDS 9500 Series Hardware Installation Guide Power Supplies Description AC input at greater than 85 V is good and power supply is functioning normally if two single 110 V or one single 220 V are connected.
Page 34
2500-W DC power supply (DC input and DC output) • The 2500-W DC power supply requires positive, negative, and ground wires. (See Figure 1-7 1 AC power connection 2 Power supply LEDs 3 Captive screws Cisco MDS 9500 Series Hardware Installation Guide 1-12 Figure 1-7.) Figure Figure 1-9.)
Page 35
Figure 1-8 1 AC power connection 2 Power cable 3 Power supply switch OL-19587-01 3000-W AC Power Supply for the Cisco MDS 9509 Director 4 Power supply LEDs 5 Captive screws Cisco MDS 9500 Series Hardware Installation Guide Power Supplies 1-13...
Page 36
3 Power supply switch Figure 1-10 1 Terminal block cover 2 Power supply LEDs 3 Captive screw Cisco MDS 9500 Series Hardware Installation Guide 1-14 2500-W AC Power Supply for the Cisco MDS 9509 Director INPU T OUT PUT FAIL...
Page 37
2 Captive screws Power Supply LEDs for the Cisco MDS 9509 and 9506 Directors Status Green Green Cisco MDS 9500 Series Hardware Installation Guide Power Supplies Figure 1-11), except for the label Description AC input is good and power supply is functioning normally.
Both the supervisor modules provide the control and management functions for the Cisco MDS 9500 Series. The Cisco MDS 9500 Series supports two supervisor modules for redundancy. In the event of an internal component failure, the standby supervisor module takes over, if installed. This section...
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Supervisor-2 Modules The Cisco MDS 9500 Series offers redundant, hot-swappable, Supervisor-2 modules. (See Supervisor-2 modules can be used in the Cisco MDS 9509 and 9506 Directors in slots 5 and 6.
Port Interfaces The Supervisor-2 module provides the following port interfaces: RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to: • Configure the Cisco MDS 9500 Series from the CLI – – Monitor network statistics and errors –...
The LEDs on the Supervisor-2 module indicate the status of the Supervisor-2 module, power supplies, and fan module. Figure 1-13 OL-19587-01 Table 1-4 provides more information about these LEDs. Supervisor-2 Module LEDs Cisco MDS 9500 Series Hardware Installation Guide Supervisor Modules Figure 1-13). 1-19...
Page 42
MGMT 10/100 Ethernet Activity LED CompactFlash Cisco MDS 9500 Series Hardware Installation Guide 1-20 LEDs for the Cisco MDS 9500 Series Supervisor-2 Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence). Orange One of the following occurs: The module is booting or running diagnostics •...
LEDs on the Supervisor-1 Module, page 1-23 • Note Supervisor-1 is not supported on the Cisco MDS 9513 Director. Figure 1-14 shows a Cisco MDS 9500 Series Supervisor-1 module. Figure 1-14 1 Status, System, Active, and Pwr Mgmt LEDs 2 Reset button...
192-Gbps full duplex bandwidth per switching module. The Cisco MDS 9500 Series supports redundant supervisor modules. Upon power up with slots 5 and 6 active, the supervisors negotiate to determine which one is active and which is the standby supervisor.
The LEDs on the Supervisor-1 module indicate the status of the Supervisor-1 module, power supplies, and fan module. Figure 1-15 OL-19587-01 Table 1-5 provides more information about these LEDs. Supervisor-1 Module LEDs Cisco MDS 9500 Series Hardware Installation Guide Supervisor Modules Figure 1-15). 1-23...
Page 46
1. The System and Pwr Mgmt LEDs on a redundant supervisor module are synchronized to the active supervisor module. Cisco MDS 9500 Series Hardware Installation Guide 1-24 LEDs for the Cisco MDS 9500 Series Supervisor Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence).
LEDs. For information regarding migrating to Generation 3 modules, see the “Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules” section on page A-1. Figure 1-16 Crossbar Module LEDs 181335 Cisco MDS 9500 Series Hardware Installation Guide 1-25 OL-19587-01...
Page 48
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Table 1-6 Status Cisco MDS 9500 Series Hardware Installation Guide 1-26 LEDs for the Cisco MDS 9500 Crossbar Modules...
Using any combination of modules that include a Generation 1 module or a Supervisor-1 module limits the port index availability to 252 on all Cisco MDS 9500 Series directors. Generation 1 modules also require contiguous port indexes where the system assigns a block of port index numbers contiguously...
Page 51
Using any combination of modules that include a Generation 1 module and a Supervisor-2 module limits the port index availability to 252 on all Cisco MDS 9500 Series Directors. The Generation 1 modules can use any contiguous block of port indexes that start on the first port index reserved for any slot in the range 0-252.
Generation 1 storage IPS modules and Generation 2 modules on a Cisco MDS 9509 Director. In this example, one of the modules installed will not boot up because the number of port indexes needed has been exceeded. Cisco MDS 9500 Series Hardware Installation Guide 1-30 Port Index Requirements...
Page 53
Using any combination of modules that include a Generation 1 module and a Supervisor-2 module limits the port index availability to 252 on all Cisco MDS 9500 Series Directors. But the Generation 1 modules can use any contiguous block of port indexes in the range 0–252 (See Using any combination of only Generation 2 with a Supervisor-2 module allows a maximum of 528 (with an architectural limit of 1020) port indexes on all Cisco MDS 9500 Series Directors.
16-Port 2-Gbps Fibre Channel Switching Module – The Cisco MDS 9500 Series supports up to eleven hot-swappable switching modules. By combining different switching modules in a single, modular chassis, you can design cost and performance optimized storage networks in a wide range of application environments.
The 4/44-port 8-Gbps Host-Optimized Fibre Channel switching module offers 48 autosensing 1-, 2-, 4- and 8-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9222i Switches. The 48-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
The 48-port 4-Gbps Fibre Channel switching module offers 48 autosensing 1-, 2-, and 4-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. The 48-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
The 24-port 4-Gbps Fibre Channel switching module offers 24 autosensing 1-, 2-, and 4-Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches. The 24-port switching module can be configured in one of two operational modes: shared bandwidth mode (default) and dedicated bandwidth mode.
4-port 10-Gbps switching module. The front panel connectors support standard modular X2 interfaces and the speed is fixed at 10 Gbps. Figure 1-24 Status LED X2 port interfaces Cisco MDS 9500 Series Hardware Installation Guide 1-36 4-Port 10-Gbps Fibre Channel Switching Module Chapter 1 Product Overview...
Link is up. Link is up (traffic on port). Link is disabled by software. A fault condition exists. No link. Cisco MDS 9500 Series Hardware Installation Guide Switching Modules Figure 1-25 shows a 1-37...
Figure 1-26 1 Status LED 2 1-Gbps/2-Gbps Fibre Channel ports Cisco MDS 9500 Series Hardware Installation Guide 1-38 Cisco MDS 9000 Family 32-Port 2-Gbps Switching Module 3 Link LEDs (under ports, on left) and Speed LEDs (under ports, on right)
Each switching module has a hardware watchdog timer for detecting most component failures. This watchdog resets the card if is not serviced periodically. Cisco MDS 9500 Series Hardware Installation Guide 1-39 OL-19587-01...
Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide. Cisco MDS 9500 Series Hardware Installation Guide 1-40 LEDs for the Cisco MDS 9000 Family Generation 1 Fibre Channel Switching Modules Description All diagnostics pass.
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Services Modules The Cisco MDS 9500 Series supports the following hot-swappable Generation 1 services modules: 16-Port Storage Services Module, page 1-41 •...
Page 64
The module provides intelligent diagnostics, protocol decoding, and network analysis tools as well as integrated Call Home capability for added reliability, faster problem resolution, and reduced service costs. Cisco MDS 9500 Series Hardware Installation Guide 1-42 Link LEDs Chapter 1...
Solid green Solid yellow Flashing yellow Cisco MDS 9500 Series Hardware Installation Guide 1-44 LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules Description All diagnostics pass. The module is operational (normal initialization sequence). One of the following occurs or occurred: •...
(CWDM) SFP transceivers, which can be used for extended long wavelength (ELWL) transmission or for CWDM. See the “Supported Transceivers” section on page 1-56. Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release Note 4.1(1b) support the MPS-14/2 module. Cisco MDS 9500 Series Hardware Installation Guide...
Table 1-16 describes the LEDs for the MPS-14/2 modules. Table 1-16 Status Status Green Orange Speed On Cisco MDS 9500 Series Hardware Installation Guide 1-46 Cisco MDS 9000 Family MPS-14/2 Module —SPEED LINK— —SPEED LINK— LEDs for the Cisco MDS 9000 Family MPS-14/2 Modules Description All diagnostics pass.
Link is disabled by software. A fault condition exists. No link. “Supported Transceivers” section on page Cisco MDS 9000 Family IPS-8 Services Module 3 Link LEDs 4 Asset tag Cisco MDS 9500 Series Hardware Installation Guide Services Modules 1-56. 1-47...
Solid green Flashing green Solid yellow Flashing yellow Cisco MDS 9500 Series Hardware Installation Guide 1-48 Cisco MDS 9000 Family IPS-4 Services Module LINK LINK LINK 3 Link LEDs 4 Asset tag LEDs for the Cisco MDS 9000 Family IPS Module Description All diagnostics pass.
ASM-SFN boot variable, see the Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration OL-19587-01 1-56. Fibre Channel ASM 3 Link and Speed LEDs 4 Asset tag Guide. Cisco MDS 9500 Series Hardware Installation Guide Services Modules “Supported 1-49...
Table 1-18 describes the LEDs for the Advanced Services module. Table 1-18 Status Speed Link Cisco MDS 9500 Series Hardware Installation Guide 1-50 LEDs for the Cisco MDS 9000 Family Fibre Channel ASMs Status Description Green All diagnostics pass and the module is operational (normal initialization sequence).
32 Fibre Channel ports, provides distributed intelligent storage services, and supports future storage services. Note Cisco MDS 9500 Series switches running Cisco MDS SAN-OS Release 2.x, 3.x, or NX-OS Release 4.1(1b) support the SSM. The Fibre Channel ports support hot-swappable Fibre Channel SFP transceivers, which can be short wavelength (SWL) for connectivity up to 1640 ft (500 m), or long wavelength (LWL) for connectivity up to 6.2 miles (10 km).
Table 1-19 describes the LEDs for the Storage Services Modules. Table 1-19 Status Speed Link Cisco MDS 9500 Series Hardware Installation Guide 1-52 LEDs for the Cisco MDS 9000 Family Storage Services Modules Status Description Green All diagnostics pass. The module is operational (normal initialization sequence).
The batteries are shipped fully charged and should be handled with caution accordingly. OL-19587-01 NODE 1 NODE 2 STATUS DISK STATUS DISK Cisco MDS 9500 Series Hardware Installation Guide Services Modules Disk 1 Status LED Node 2 LEDs Node 2 Status LED Disk 2 Status LED 1-53...
Page 76
See the “Installing a Switching or Services Module, Including Caching Services Modules” section on page 2-45 for information about installing the CSM and maintaining the CSM batteries. Cisco MDS 9500 Series Hardware Installation Guide 1-54 CSM, Internal View Chapter 1...
Battery does not have power and is not charged. Solid green Disk is operational. Flashing orange Dumping cache to disk. Flashing green Restoring cache from disk. Disk failure. Disk does not have power. Cisco MDS 9500 Series Hardware Installation Guide Services Modules 1-55...
For more information about a specific Cisco SFP transceiver, see the Specifications” section on page 9500 Series. Use only Cisco transceivers in the Cisco MDS 9500 Series. Each Cisco transceiver is encoded with Note model information that enables the switch to verify that the transceiver meets the requirements for the switch.
SFP+ Transceiver Specifications” section on page Combination Fibre Channel/Gigabit Ethernet SFP Transceivers The combination Fibre Channel/Gigabit Ethernet SFP transceivers from Cisco Systems are available in SWL or LWL versions. Both of these versions are 1-Gbps/2-Gbps capable. The combination SFP transceivers from Cisco Systems have LC connectors and comply with 1-Gbps/2-Gbps Fibre Channel as defined in FC-PI 10.0 2 and Gigabit Ethernet as defined in IEEE...
• ELWL signals can transmit over longer distances than LWL SFP transceivers. For more information about Gigabit Ethernet SFP transceiver specifications, see the Transceiver Specifications” section on page Cisco MDS 9500 Series Hardware Installation Guide 1-58 Chapter 1 C-22. C-22.
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Installing the Cisco MDS 9500 Series This chapter describes how to install the Cisco MDS 9500 Series chassis and its components, and includes the following information: Preinstallation, page 2-2 •...
– rack-mount kit shipped with the switch In a perforated or solid-walled EIA cabinet, using: • The rack-mount kit shipped with the switch – Cisco MDS 9500 Series Hardware Installation Guide Chapter 2 Installing the Cisco MDS 9500 Series OL-19587-01...
The telco and EIA Shelf Bracket Kit is not intended for use with a Cisco MDS 9513 Director or Cisco MDS 9509 Director in a two-post telco rack. Installation Guidelines Follow these guidelines when installing the Cisco MDS 9500 Series: • Plan your site configuration and prepare the site before installing the chassis. Cisco recommends...
An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded either through the power cable, the chassis ground, or metal-to-metal contact with a grounded rack. OL-19587-01 Cisco MDS 9500 Series Hardware Installation Guide Preinstallation...
Installing the Chassis in a Cabinet or Rack This section describes how to install the Cisco MDS 9500 Series in a cabinet or rack that meets the requirements described in this document, using the rack-mount kit provided with the switch. A separate procedure is provided for each type of director: •...
Contents for the Rack-Mount Support Bracket Kit Part Description Rack-mount support bracket Rack-mount support bar 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack...
Page 88
Install one rack-mount support bar into the slots located on the rack-mount support brackets. Repeat this for the other support bar. Cisco MDS 9500 Series Hardware Installation Guide 2-1). The top four screws will be used to install the cable management bracket to the rail.
Page 89
These will be installed after placing the cable management bracket along that side. The bottom screw should be installed to support the front of the rack-mount support bracket. OL-19587-01 Rack-mount support bar Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack...
Page 90
3/4-inch or 10-32 x 3/4-inch screws, using six screws per side. (See Use a minimum of six screws to ensure that the switch is adequately supported. Note Cisco MDS 9500 Series Hardware Installation Guide 2-10 Securing the Rack-Mount Support Brackets...
Cisco MDS 9509 rack-mount kit. OL-19587-01 Installing the Cable Management Brackets on the MDS 9513 Chassis 3 Mounting rail 4 Cable guide Installing the Chassis in a Cabinet or Rack Cisco MDS 9500 Series Hardware Installation Guide 2-11...
Page 92
Step 2 Repeat for the second side rack-mount bracket, ensuring that the side rack-mount brackets are at the same height. Cisco MDS 9500 Series Hardware Installation Guide 2-12 “Cisco MDS 9500 Shelf Bracket” section on page Contents of Cisco MDS 9509 Rack-Mount Kit...
Page 93
2 Screws, 12-24 or 10-32 2-6. Attaching the Crossbar to the Side Rack-Mount Brackets (Rear View) Front of rack 3 Screws, M3 4 Crossbar Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack 2-13...
Page 94
3/4-inch or 10-32 x 3/4-inch screws (see Use a minimum of six screws per side to ensure that the switch is adequately supported. Note Cisco MDS 9500 Series Hardware Installation Guide 2-14 Installing the Cisco MDS 9509 Chassis in the Rack...
Cisco MDS 9506 Director. OL-19587-01 Installing the Cable Management Bracket on the MDS 9509 Chassis 3 Mounting rail 4 Cable guide Cisco MDS 9500 Series Hardware Installation Guide Installing the Chassis in a Cabinet or Rack 2-15...
Page 96
Figure 2-9 Screws, 12-24 or 10-32 Front rack-mount bracket (behind cable guide) Cisco MDS 9500 Series Hardware Installation Guide 2-16 Contents of Cisco MDS 9506 Rack-Mount Kit Installing the Cisco MDS 9506 Chassis in the Rack Chapter 2 Installing the Cisco MDS 9500 Series...
OL-19587-01 Figure 2-9), supporting the switch inside the rack until the next step is Cisco MDS 9500 Series Hardware Installation Guide System Grounding Table 2-4 2-17...
Page 98
Existing commercial building is not subject to natural environmental noise or man-made industrial noise. This building contains a standard office environment. Cisco MDS 9500 Series Hardware Installation Guide 2-18 Grounding Best Practices Electromagnetic Noise Severity Level High High...
If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your bare skin. OL-19587-01 2-22. Cisco MDS 9500 Series Hardware Installation Guide System Grounding “Establishing the 2-19...
Page 100
If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip directly over the head of the system ground lug screw or to the system ground lug barrel. Cisco MDS 9500 Series Hardware Installation Guide 2-20...
Page 101
If you plan to return the component to the factory, immediately place it in a static shielding container. OL-19587-01 Attaching the ESD Wrist Strap to the System Ground Lug Screw 2 pt Cisco MDS 9500 Series Hardware Installation Guide System Grounding Clip installed (behind screw) System ground connector 2-21...
AC-input or DC-input power supplies, you do not need to power down the chassis. Note The system (NEBS) ground serves as the primary safety ground for the MDS 9500 series chassis that are equipped with DC-input PEMs. The DC-input power supplies for these chassis do not have a separate ground.
Wire-stripping tool to remove the insulation from the grounding wire. Grounding the Chassis This section describes how to connect the Cisco MDS 9500 Series to earth ground. You must complete this procedure before connecting system power or powering up your shelf.
Page 104
NRTL listed grounding lug Figure 2-12 shows the ESD ground location on the rear panel of the Cisco MDS 9513 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-24 System Ground Location on the Cisco MDS 9513 Chassis (Front) Chapter 2...
Page 105
For a Cisco MDS 9506 Director with a DC power supply, the chassis ground is required. Figure 2-13 shows the system ground location on the Cisco MDS 9509 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-25 OL-19587-01...
Page 106
NEC code for ampacity. Figure 2-14 shows the system ground location on the Cisco MDS 9506 chassis. Cisco MDS 9500 Series Hardware Installation Guide 2-26 System Ground Location on the Cisco MDS 9509 Chassis 4 Screws, M4, with square cone washers...
Page 107
OL-19587-01 System Ground Location on the Cisco MDS 9506 Chassis 4 Screws, M4, with square cone washers 5 NRTL listed grounding lug 6 Close-up of grounding pad on switch Cisco MDS 9500 Series Hardware Installation Guide Grounding the Chassis 2-27...
Providing Power to a DC Power Supply in the Cisco MDS 9509 Director, page 2-33 • Providing Power to a DC Power Supply in the Cisco MDS 9506 Director, page 2-34 Cisco MDS 9500 Series Hardware Installation Guide 2-28 Chapter 2 Installing the Cisco MDS 9500 Series Appendix C, “Technical Specifications.”...
FAN OK LEDs are green. • OUTPUT FAIL LED is off. • Table 1-2 on page 1-11 OL-19587-01 Cable Retention on the Power Supply for power supply LED details. Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch Cable retention 2-29...
2 Power cable retainer 3 Power supply switch Figure 2-17 shows a 4000-W AC power supply for the Cisco MDS 9509 Director. Cisco MDS 9500 Series Hardware Installation Guide 2-30 2500-W AC Power Supply for the Cisco MDS 9509 Director INPU T...
Page 111
4000-W AC Power Supply for the Cisco MDS 9509 Director INPU T OUT PUT FAIL 4 Power supply switch 5 Permanent power cable AC PEM for Cisco MDS 9506 Director 3 AC power connection Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch 2-31...
Page 112
Note Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9500 Series director to your outlet receptacle. See “Jumper Power Cord” section on page Cisco MDS 9500 Series Hardware Installation Guide...
OL-19587-01 2-17. 2500-W DC Power Supply for the Cisco MDS 9509 Director INP UT OUT PUT FAIL 4 Power supply switch 5 Terminal block Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch “System Grounding” 2-33...
Providing Power to a DC Power Supply in the Cisco MDS 9506 Director Before performing any of the following procedures, ensure that power is removed from the DC circuit. Warning Statement 1003 Cisco MDS 9500 Series Hardware Installation Guide 2-34 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding”...
Page 115
OL-19587-01 2-17. DC PEM for a Cisco MDS 9506 Director 4 Exposed portion of positive cable 5 Insulated portion of negative cable Cisco MDS 9500 Series Hardware Installation Guide Starting Up the Switch “System Grounding” “System Grounding” section on 2-35...
Fundamentals Configuration Guide or the Cisco Fabric Manager Fundamentals Configuration Guide. For instructions on connecting to the console port, see the page 3-2). Cisco MDS 9500 Series Hardware Installation Guide 2-36 Chapter 2 Installing the Cisco MDS 9500 Series “Connecting to the Console Port” section on...
Page 117
If a component is not operating correctly, try removing and reinstalling it. If it still does not operate correctly, contact your customer service representative for a replacement. OL-19587-01 Appendix C, “Technical Specifications,” Appendix C, “Technical Specifications.” Starting Up the Switch “System Grounding” section on for the required voltages. Cisco MDS 9500 Series Hardware Installation Guide 2-37...
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Step 11 Verify that the system software has booted and the switch has initialized without error messages.
Note Install the Cisco MDS 9500 Series chassis in the rack before installing modules. See the Chassis in a Cabinet or Rack” section on page In systems with redundant supervisor modules, you can replace the faulty supervisor while the system Note is operating, provided that one supervisor is always operating.
To remove a currently installed module, see the Modules” section on page Open both the ejector levers on the new or replacement module completely. (See Step 5 Cisco MDS 9500 Series Hardware Installation Guide 2-40 Figure 1-3 on page 1-6 Figure 1-4 on page 1-7 2-45.
Page 121
(see OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Positioning a Module in the Chassis 3 EMI Gasket 4 Ejector level (fully extended) Figure Cisco MDS 9500 Series Hardware Installation Guide 2-23). 2-41...
Page 122
Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create a small 0.040-inch (1-mm) gap between the module’s EMI gasket and the module above it. (See Figure 2-24.) Cisco MDS 9500 Series Hardware Installation Guide 2-42 Clearing the EMI Gasket Press down gently...
Page 123
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Closing the Ejector Levers Ejector levers flush with module faceplate Cisco MDS 9500 Series Hardware Installation Guide 2-43...
Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029 Cisco MDS 9500 Series Hardware Installation Guide 2-44 Chapter 2...
Verify that the captive screws are tightened to 8 in-lb on all modules already installed in the chassis. This ensures that the EMI gaskets are fully compressed and maximizes the opening space for the module being installed. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules 2-6. Cisco MDS 9500 Series Hardware Installation Guide 2-45...
8 in-lb. Step 3 Verify that any empty module slots have filler panels installed and that the screws holding the panels in place are tight. Cisco MDS 9500 Series Hardware Installation Guide 2-46 “Removing Other Switching and Services 2-45.
Hold the front edge of the module and slide the module partially out of the slot. Do not touch the module circuitry. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Figure 2-25.) Cisco MDS 9500 Series Hardware Installation Guide 2-47...
Page 128
To install a crossbar module in the Cisco MDS 9513 Director, follow these steps: Before installing any modules, install at least one Supervisor-2 module. Step 1 Cisco MDS 9500 Series Hardware Installation Guide 2-48 Captive Screws and Ejector Levers on the Crossbar Module...
Page 129
The ejector levers are completely closed when they are flush with the front of the module. OL-19587-01 Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Figure Installing the Crossbar Module Cisco MDS 9500 Series Hardware Installation Guide 2-26.) 2-49...
The batteries are automatically charged on a periodic basis with an SMBus-compliant Level III smart charger located on the CSM. The smart charger measures the charge and recharges the battery to full if it is less than 90 percent of capacity. Cisco MDS 9500 Series Hardware Installation Guide 2-50 Chapter 2...
Use both hands to install and remove power supplies. Each DC power supply for the Cisco MDS 9500 Series weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg). You can replace the faulty power supply while the system is operating if the other power supply is Note functioning.
Cable retention device Step 4 Loosen all four 6-32 panel fasteners at the corners of the power supply. Cisco MDS 9500 Series Hardware Installation Guide 2-52 Cable Retention Device on the 6000W Power Supply Chapter 2 Installing the Cisco MDS 9500 Series...
Page 133
OL-19587-01 2-28.) Handling a Power Supply for the Cisco MDS 9513 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-53...
Step 3 Ensure that the power switch is in the off (0) position on the power supply you are installing. (See Figure 2-29.) Cisco MDS 9500 Series Hardware Installation Guide 2-54 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding” section...
Page 135
FANs OK LED is green. • OUTPUT FAIL LED is off. • OL-19587-01 AC Power Supply for the Cisco MDS 9513 Director 2 Power cable retainer Removing and Installing a Power Supply or PEM Cisco MDS 9500 Series Hardware Installation Guide 2-55...
Note power supply. Step 4 Loosen the captive screw. Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series AC power Caution supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg). Step 5 Grasp the power supply handle with one hand, and slide the power supply partially out of the chassis.
If a filler panel is installed, remove the filler panel from the power supply bay by loosening the captive Step 2 screw. OL-19587-01 Handling a Power Supply for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM “System Grounding” section 2-57...
Page 138
Figure 2-33 Figure 2-31 1 AC power connection 2 Power supply LEDs 3 Captive screw Cisco MDS 9500 Series Hardware Installation Guide 2-58 Figure 2-31 for the location of the switch. 4000-W AC Power Supply for the Cisco MDS 9509 Director...
Page 139
Figure 2-32 3000-W AC Power Supply for the Cisco MDS 9509 Director 1 AC power connection 2 Power cable 3 Power supply switch OL-19587-01 4 Power supply LEDs 5 Captive screws Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-59...
Page 140
If the LEDs indicate a power problem, see the Cisco MDS 9000 Family Troubleshooting Guide. If you cannot resolve an issue, contact your customer service representative. Cisco MDS 9500 Series Hardware Installation Guide 2-60 2500-W AC Power Supply for the Cisco MDS 9509 Director...
(DC-I). Loosen the captive screw on the power supply. Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 OL-19587-01 Removing and Installing a Power Supply or PEM Cisco MDS 9500 Series Hardware Installation Guide 2-61...
1 Terminal block cover 2 Power supply LEDs 3 Captive screw Use both hands to install and remove power supplies. Each Cisco MDS 9500 Series DC power Caution supply weighs between 22 lb (9.9 kg) and 28 lb (12.6 kg).
Page 143
Verify power supply operation by checking that the power supply LEDs are in the following states: • INPUT OK LED is green. FAN OK LED is green. • Output fail LED is off. • OL-19587-01 Removing and Installing a Power Supply or PEM “System Grounding” section Cisco MDS 9500 Series Hardware Installation Guide 2-63...
Step 3 Remove the cables from the DC PEM by removing the terminal block screws, and then removing the ring lugs from the screws. See Cisco MDS 9500 Series Hardware Installation Guide 2-64 Chapter 2 “Connecting the Power Supplies” section Figure 2-35 for the location of the terminal block screws.
Page 145
If the PEM bay is to remain empty, install a PEM filler panel over the opening and tighten the captive screws to 8 in-lb. OL-19587-01 Connecting or Disconnecting the DC PEM 4 Stripped portion of positive cable 5 Insulated portion of negative cable Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM 2-65...
INPUT OK LED is green. • • FAN OK LED is green. Cisco MDS 9500 Series Hardware Installation Guide 2-66 Chapter 2 Installing the Cisco MDS 9500 Series “System Grounding” section “Providing Power to an AC Power Supply for the Cisco 2-30.
OL-19587-01 Figure 2-36 Handling a Power Supply for the Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing a Power Supply or PEM “Removing a DC PEM” section on page and slide the power supply completely out of 2-64.
You need a flat-blade or number 2 Phillips screwdriver to perform these procedures. Because the fan modules are located on the left side of the Cisco MDS 9500 Series, Cisco recommends Note guiding the cables for the system out of the right side of the chassis.
Grasp the fan module with both hands and pull it outward; rock it gently, if necessary, to unseat the power Step 2 connector from the backplane. Step 3 Pull the fan module clear of the chassis. (See OL-19587-01 Removing and Installing Fan Modules Figure 2-37.) Cisco MDS 9500 Series Hardware Installation Guide 2-69...
Verify that the Fan Status LED is green. If the LED is not green, one or more fans are faulty. If this Step 4 occurs, contact your customer service representative for a replacement part. Cisco MDS 9500 Series Hardware Installation Guide 2-70 Removing the Fan Module for the Cisco MDS 9513 Director...
Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing the Crossbar Module Fan Tray...
Slide the module carefully into the slot until the the fan tray is fully inserted into the chassis. Tighten the two captive screws on the crossbar module fan tray to 8 in-lb screws. Cisco MDS 9500 Series Hardware Installation Guide 2-72...
OL-19587-01 Handling the Fan Module for the Cisco MDS 9509 Director Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Fan Modules Figure 2-39) by turning them counterclockwise;...
If you purchased this product through a Cisco reseller, contact the reseller directly for technical Note support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing a Front Fan Module on the Cisco MDS 9506 Director...
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Removing and Installing CompactFlash Cards The supervisor module has one slot for an optional CompactFlash card.
Removing and Installing Clock Modules The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of the chassis. In the unlikely event of a clock module failure, Cisco recommends that the failed clock module be replaced during a maintenance window.
Figure 2-40 shows the clock modules in a rear view of the Cisco Clock Module Location on the Cisco MDS 9513 Director (Rear View) Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Clock B (CLK B)
Page 158
Step 4 Figure 2-41 Sheet metal side Step 5 Repeat Step 3 Cisco MDS 9500 Series Hardware Installation Guide 2-78 Clock Module Replacement on the Cisco MDS 9513 Director (Rear View) Component side Step 4 to remove any additional clock modules.
FAN OK LED is green. OL-19587-01 Clock Module for the Cisco MDS 9513 Director through Step 4 to install any additional clock modules. Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Figure 2-42). “Connecting the Power Supplies” section on 2-79...
Figure 2-43 shows the clock modules in a rear view of the Cisco MDS 9509 Director with the back panel removed. Cisco MDS 9500 Series Hardware Installation Guide 2-80 Contents of Cisco MDS 9509 Clock Module Replacement Kits Chapter 2...
Page 161
OL-19587-01 Clock Module Location on the Cisco MDS 9509 Director (Rear View) 2-33. Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules Clock B (CLK B) “Providing Power to a DC Power Supply in...
Page 162
Disconnect and gently remove the module, placing it on an antistatic mat or foam. Step 4 Repeat Step 3 Step 5 Cisco MDS 9500 Series Hardware Installation Guide 2-82 Clock Module Replacement on the Cisco MDS 9509 Director (Rear View) Connectors Connectors Step 4 to remove any additional clock modules.
Step 4 to install any additional clock modules. Contents of Cisco MDS 9506 Clock Module Replacement Kit Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules “Connecting the Power Supplies” section on Table 2-7 lists the contents of the...
Page 164
Clock module Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal components. Cisco MDS 9500 Series Hardware Installation Guide 2-84 Clock Module Location on the Cisco MDS 9506 Director (Rear View) Chapter 2...
Page 165
OL-19587-01 Clock Module Replacement on the Cisco MDS 9506 Director (Rear View) Connector Clock module Cisco MDS 9500 Series Hardware Installation Guide Removing and Installing Clock Modules “Removing a DC PEM” section on page Figure 2-46). 2-64.
INPUT OK LED is green. • • FAN OK LED is green. • OUTPUT FAIL LED is off. Cisco MDS 9500 Series Hardware Installation Guide 2-86 Chapter 2 Installing the Cisco MDS 9500 Series “Connecting the Power Supplies” section on page 2-28.
Page 167
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Connecting the Cisco MDS 9500 Series The Cisco MDS 9500 Series provides the following types of ports: •...
Preparing for Network Connections When preparing your site for network connections to the Cisco MDS 9500 Series, consider the following for each type of interface, and gather all the required equipment before connecting the ports: •...
Page 169
Procomm Plus—makes communication between the switch and computer possible during setup and configuration. OL-19587-01 Connecting to the Console Port on the Supervisor Module for the Cisco MDS 9500 Series C o n s o le Cisco MDS 9500 Series Hardware Installation Guide Connecting to the Console Port...
Switches running Cisco MDS SAN-OS Release 1.2(1a) or later NX-OS Release 4.1(1b) or later support Note the connection of a COM1 port to a modem. Cisco MDS 9500 Series Hardware Installation Guide Chapter 3 Connecting the Cisco MDS 9500 Series Figure 3-2).
Page 171
Connect the adapters using the RJ-45 to RJ-45 rollover cable (or equivalent crossover cable). OL-19587-01 Connecting to the COM1 Port on the Supervisor Module for the Cisco MDS 9500 Series Cisco MDS 9500 Series Hardware Installation Guide Connecting to the COM1 Port...
10/100/1000”) and has an RJ-45 interface. (See the switch by IP address, such as through Cisco Fabric Manager. Figure 3-3 Cisco MDS 9500 Series Hardware Installation Guide Figure Connecting to the MGMT 10/100/1000 Ethernet Port on the Supervisor-2 Module for...
10/100”) and has an RJ-45 interface. (See switch by IP address, such as through Cisco Fabric Manager. OL-19587-01 Connecting to the MGMT 10/100 Ethernet Port Figure 3-4.) You can use this port to access and manage the Cisco MDS 9500 Series Hardware Installation Guide...
Page 174
IP address. This process requires an Ethernet connection to the newly activated supervisor module. Cisco MDS 9500 Series Hardware Installation Guide Connecting to the MGMT 10/100 Ethernet Port on the Supervisor-1 Module for the Cisco MDS 9500 Series...
For instructions specific to the transceiver type, see “X2 Transceiver Specifications” section on page OL-19587-01 Connecting to a Fibre Channel Port Table C-19 on page C-20 on the Cisco MDS 9200 Series. Each C-19. Cisco MDS 9500 Series Hardware Installation Guide...
Page 176
Transmit optical bore Receive optical bore Latching sleeve (retracted) EMI gasket Transceiver heat sink Cisco MDS 9500 Series Hardware Installation Guide 3-10 Cisco MDS 9000 Family X2 Transceivers Chapter 3 Connecting the Cisco MDS 9500 Series Figure 3-5.)
Step 3 If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end Note of the transceiver. OL-19587-01 Connecting to a Fibre Channel Port Cisco MDS 9500 Series Hardware Installation Guide 3-11...
Record the cable and port connections for later reference. Press the release latch on the cable, grasp the connector near the connection point, and gently pull the connector from the transceiver. Cisco MDS 9500 Series Hardware Installation Guide 3-12 C-22.
Page 179
If another transceiver is not being installed, protect the optical cage by inserting a clean cover. OL-19587-01 3-8). Be careful not to damage the port cage during this process. Alternate Removal Method for Bale Clasp SFP Transceivers Cisco MDS 9500 Series Hardware Installation Guide Connecting to a Fibre Channel Port 3-13...
If the cable does not remove easily, ensure that any latch present on the cable has been released before continuing. To remove the cable, follow these steps: Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use. Cisco MDS 9500 Series Hardware Installation Guide 3-14 Chapter 3 Connecting the Cisco MDS 9500 Series OL-19587-01...
Configuration Guide or the Cisco Fabric Manager Fundamentals Configuration Guide. . OL-19587-01 Figure 3-9). Connecting the LC-Type Cable to a Fibre Channel Port LC plug SFP module Connecting to a Fibre Channel Port Cisco MDS 9500 Series Hardware Installation Guide 3-15...
• Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco MDS 9500 Series Hardware Installation Guide 3-16 Chapter 3 Connecting the Cisco MDS 9500 Series...
Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules This appendix describes the tasks associated with readying the MDS 9500 Series to support Generation 3 8-Gbps Fibre Channel switching modules. It presents an overview of the Generation 3 8-Gbps modules, provides usage guidelines for the modules, and describes three procedures for migrating hardware and upgrading software to enable use of these modules in an MDS 9513 Director.
4/44-port 8-Gbps Host-Optimized module, follow these steps: Connect a PC to the console port on the active supervisor module and log in to the switch. Step 1 OL-19587-01 Before You Begin Upgrading the MDS 9513 Director Cisco MDS 9500 Series Hardware Installation Guide...
Page 186
Cisco Storage Area Networking Operating System (SAN-OS) Software TAC support: http://www.cisco.com/tac Copyright (c) 2002-2006, Cisco Systems, Inc. All rights reserved. The copyrights to certain works contained herein are owned by other third parties and are used and distributed under license.
(in slot 7) and its associated fabric module in the Fabric 1 slot. OL-19587-01 Module-Type -------------------------------- ------------------ ------------ Supervisor/Fabric-2 Supervisor/Fabric-2 Migration Procedures for the MDS 9513 Director Model Status DS-X9530-SF2-K9 ha-standby DS-X9530-SF2-K9 active * Cisco MDS 9500 Series Hardware Installation Guide...
Page 188
Hold the front edge of the module and slide the module partially out of the slot. Do not touch the module circuitry. Cisco MDS 9500 Series Hardware Installation Guide Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules...
Page 189
(See OL-19587-01 Captive Screws and Ejector Levers on the Fabric Module Figure Cisco MDS 9500 Series Hardware Installation Guide Migration Procedures for the MDS 9513 Director Ejector levers Fabric slot 2 label...
Page 190
If it does not, check to see if the module is seated correctly in the slot. Step 13 Enter the system switchover command to put the other supervisor in active mode. Cisco MDS 9500 Series Hardware Installation Guide Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Installing a Fabric Module...
MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section on page Step 6 Enter the show hardware fabric-mode command to display information about Generation 3 module support. Cisco MDS 9500 Series Hardware Installation Guide A-10 Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules A-11.
Power up the switch by turning the power supply switch at the rear of the power supply clockwise to the Step 7 on position on both power supplies. OL-19587-01 “Installing MDS 9513 Fabric 2 Modules and Running Cisco SAN-OS 3.x” section Cisco MDS 9500 Series Hardware Installation Guide Migration Procedures for the MDS 9513 Director A-11...
4.1(0.182) MAC-Address(es) -------------------------------------- 00-19-56-be-65-d0 to 00-19-56-be-65-d8 00-0c-30-0d-2b-b8 to 00-0c-30-0d-2b-bc 00-05-30-00-52-f2 to 00-05-30-00-52-f6 Cisco MDS 9500 Series Hardware Installation Guide A-12 Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Module-Type -------------------------------- ------------------ ------------ 4x1GE IPS, 18x1/2/4Gbps FC Modul DS-X9304-18K9...
Page 195
OL-19587-01 Migration Procedure for the MDS 9509 Director and MDS 9506 Director 2-40. Refer to the Migrating from Supervisor-1 Modules to Supervisor-2 Modules Cisco MDS 9500 Series Hardware Installation Guide 2-39. If the switch has Supervisor-2 modules “Installing Supervisor Modules”...
Page 196
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
B-6. OL-19587-01 A P P E N D I X and the “Requirements Specific to Solid-Walled B-4. “Requirements Specific to Two-Post Telco Racks” section Cisco MDS 9500 Series Hardware Installation Guide F (0 to 40 “Requirements Specific to...
Optional jumper power cords are available for use in a cabinet. See the Note page D-11. Cisco MDS 9500 Series Hardware Installation Guide “Installing the Cisco MDS 9513 Director in a Rack” section 2-7. Appendix B Cabinet and Rack Installation “Jumper Power Cord”...
Cisco recommends that the roof should be perforated with at least a 20 percent open area. • Cisco recommends an open or perforated cabinet floor to enhance cooling. • OL-19587-01 “General Requirements for Cabinets and Racks” section on Chassis. Cisco MDS 9500 Series Hardware Installation Guide Cabinet and Rack Requirements Perforated Cabinet Requirements...
The solid-walled cabinet requirements for the Cisco MDS 9513 chassis are as follows: • Perforated front and back doors and solid or open side panels. Cisco MDS 9500 Series Hardware Installation Guide B-1, solid-walled cabinets must meet the following requirements: Appendix B Cabinet and Rack Installation “General Requirements for Cabinets and...
Director only, and can be removed or left installed once the front rack-mount brackets are securely fastened to the rack-mounting rails. The Cisco MDS 9506 Director does not require shelf brackets. Note OL-19587-01 Cabinet and Rack Requirements “General Requirements for Cabinets and Racks” section on Cisco MDS 9500 Series Hardware Installation Guide...
• This optional kit is not provided with the switch; to order the kit, contact your switch supplier. Note Cisco MDS 9500 Series Hardware Installation Guide Appendix B Cabinet and Rack Installation “General Requirements for Cabinets and Racks” section on...
Support rack-mount bracket Rack-mount support brace 12-24 x 3/4-in. Phillips screws 10-32 x 3/4-in. Phillips screws Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket B-1. This is particularly important to MDS 9222i...
You need the following equipment for this installation: • Number 2 Phillips screwdriver Tape measure and level (to ensure shelf brackets are level) • Cisco MDS 9500 Series Hardware Installation Guide Contents of Shelf Bracket Kit Part Description Slider brackets Shelf brackets Crossbar 10-32 x 3/8-in.
Installing the Shelf Bracket Kit into a Two-Post Telco Rack 3 10-32 screws (2x) 4 Crossbar Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket Figure B-1. Align the screw holes at the Figure B-1, using the 10-32 screws.
Step 2 Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired). Cisco MDS 9500 Series Hardware Installation Guide B-10 Installing the Shelf Bracket Kit into an EIA Rack 4 Crossbar...
M4 holes on the chassis for attaching a grounding lug. OL-19587-01 2-6. 2-6. Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9000 Family Telco and EIA Shelf Bracket Figure B-2, using the 10-32 screws.
Removing the Shelf Bracket Kit (Optional) The shelf bracket kit can be removed once the Cisco MDS 9500 Series has been installed in a two-post telco or four-post EIA rack, and the front rack-mount brackets are securely attached to the rack-mounting rails.
Installing the Cisco MDS 9500 Shelf Bracket Kit into a Cabinet or Rack, page B-15 • Installing the Switch on the Shelf Brackets, page B-16 OL-19587-01 B-1. Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9500 Shelf Bracket “Cabinet and Rack Requirements” B-13...
Page 210
Number 2 Phillips screwdriver • Tape measure and level (to ensure shelf brackets are level) • Cisco MDS 9500 Series Hardware Installation Guide B-14 “Cabinet and Rack Requirements” section on page Appendix C, “Technical Specifications.” Contents of Cisco MDS 9500 Shelf Bracket Kit...
Page 211
Verify that the shelf brackets are at the same height (using the level or tape measure as desired). Step 4 OL-19587-01 Installing the Shelf Bracket Kit into a Rack Cisco MDS 9500 Series Hardware Installation Guide Cisco MDS 9500 Shelf Bracket Figure B-3. Align the screw holes at...
Page 212
Caution We recommend grounding the chassis, although the rack is already grounded. There is a grounding pad with two threaded M4 holes on the chassis for attaching a grounding lug. Cisco MDS 9500 Series Hardware Installation Guide B-16 Appendix B Cabinet and Rack Installation “Installing the Chassis in a Cabinet or Rack”...
Specifications for cables and connectors are provided in Switch Specifications The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per minute) of airflow per slot with 410 W of power dissipation per slot. Table C-1 lists the environmental specifications for the Cisco MDS 9500 Series.
Page 214
Table C-3 Description Dimensions (HxWxD) Weight Cisco MDS 9500 Series Hardware Installation Guide Physical Specifications for the Cisco MDS 9513 Director Specification 24.5 x 17.5 x 28 in. (62.2 x 44.5 x 71.1 cm) Chassis requires 14 RU , 15 RU with a rack-mount kit.
Page 215
Chassis configured with two supervisor modules, fan module, and two power supplies: 86 lb (39 kg). System fan tray: 7.70 lbs (3.49 kg) 1900W AC power supply: 11 lbs (4.99 kg) Cisco MDS 9500 Series Hardware Installation Guide Switch Specifications per supervisor,...
MPS-14/2 Supervisor-2 for MDS 9500 Series Supervisor-1 for MDS 9500 Series Supervisor for MDS 9200 Series OL-19587-01 Cisco MDS 9500 Series Module Specifications (continued) Specification 1.75 x15.5 x16.5 in. (4.4 x 39.4 x 41.9 cm) Note These are the maximum...
• • One AC power connection @110 VAC and one AC power connection @ 220 VAC = 2900 W output Cisco MDS 9500 Series Hardware Installation Guide Weight of Modules in the Cisco MDS 9000 Family (continued) Weight 2.25 lb (1.13 kg) 0.50 lb (0.25 kg)
Page 219
@ 220 VAC = 2900 W output Two AC power connection @ 220 VAC = 6000 W output Table C-9 Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9513 Director is based on worst-case conditions. Typical numbers...
Page 220
16-port Storage Services Node, DS-X9316-SSNK9 AC Power Consumption for the Cisco MDS 9513 Director Table C-10 shows the typical AC power consumption for a Cisco MDS 9513 Director. Cisco MDS 9500 Series Hardware Installation Guide Power Heat NX-OS SAN-OS Required...
Typical AC Power Consumption for a Cisco MDS 9513 Director Specifications for Cisco MDS 9509 Power Supplies Specification Autoranging input with power factor corrector. 100 to 240 VAC (±10%). Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Typical AC Power Consumption (Watts)
Page 222
Voltage Current rating Frequency Output capacity Output voltage at 200/240 Cisco MDS 9500 Series Hardware Installation Guide C-10 Specifications for Cisco MDS 9509 Power Supplies (continued) Specification 16 A maximum at 100 to 120 VAC and 1300-W output. 16 A maximum at 200 to 240 VAC and 2500-W output.
Page 223
2.x and — — 2.x and — — 2.x and Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Table C-13 is based on worst-case conditions. Input Current 90 VAC 120 VAC 180 VAC...
Page 225
2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x 2.x and 1.x Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9509 Director Input Current Heat Dissipation 48 VDC 60 VDC...
Component Power Requirements and Heat Dissipation for the Cisco MDS 9506 Director, page C-16 • AC Power Consumption for the Cisco MDS 9506 Director, page C-19 • Cisco MDS 9500 Series Hardware Installation Guide C-14 Typical AC Power Consumption for a Cisco MDS 9509 Director Appendix C...
Page 227
1900 W maximum (at input of -48 to -60 VDC). 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 37.4 A. Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9506 Director...
Page 228
12-port 4-Gbps switching module, DS-X9112 4-port 10-Gbps switching module, DS-X9704 32-port 1-Gbps/2-Gbps Fibre Channel module DS-X9032 Cisco MDS 9500 Series Hardware Installation Guide C-16 Table C-17 list the AC and DC power requirements and heat dissipation for the Table C-16 Power Heat...
Page 229
2.x and 1260 1200 2.x and 1260 2.x and 1273 1163 4.2(1) 1273 Cisco MDS 9500 Series Hardware Installation Guide Power Specifications for the Cisco MDS 9506 Director Input Current 90 VAC 120 VAC 180 VAC (amps) (amps) (amps) 2.92 2.19...
Page 230
DS-X9304-SMIP 2.x and 1.x 32-port SSM DS-X9032-SSM 2.x and 1.x 32-port ASM DS-X9032-SMV 2.x and 1.x DS-X9560-SMC 2.x and 1.x Cisco MDS 9500 Series Hardware Installation Guide C-18 Power Heat Input Current Required Dissipation (watts) (BTU/hr) 48 VDC (amps) 3.50 3.50...
Use only Cisco X2 transceivers on the Cisco MDS 9500 Series Switches. Each Cisco X2 transceiver is encoded with the model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.
SFP and SFP+ Transceiver Specifications The Cisco MDS 9500 Series is compatible with SFP and SFP+ transceivers and cables that have LC connectors. The wavelength of each transceiver must match the transceiver on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications.
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Use only Cisco SFP transceivers on the Cisco MDS 9500 Series. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.
Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Table C-29 provides the power specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers. Table C-29 DS-SFP-FC8G-SW -1.3 Cisco MDS 9500 Series Hardware Installation Guide C-24 General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Wavelength Core Size...
Page 237
Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers Operating Maximum Minimum 40°C 0°C 40°C 0°C Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Fiber Loss Budget (dBm) Minimum 2.10 (2 2.62 (2 Gbps) Gbps) 1.78 (4 2.06 (4...
Transceivers OL-19587-01 Cisco 4-Gbps CWDM SFP Transceivers Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers Operating Maximum Minimum 40°C 0°C Cisco MDS 9500 Series Hardware Installation Guide SFP and SFP+ Transceiver Specifications Color Gray Violet Blue Green Yellow Orange Brown...
Page 244
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. Cisco MDS 9500 Series Hardware Installation Guide C-32 Optical Specification for Cisco 2-Gbps CWDM SFP Transceivers...
Table C-50 DS-SFP-GE-T For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. Cisco MDS 9500 Series Hardware Installation Guide C-34 Cisco Gigabit Ethernet SFP Transceivers Description 1-Gbps Ethernet SFP...
A single Cisco MDS 9000 family switching module supports up to eight 2-Gbps DWDM SFPs. For more information, refer to the data sheet at: http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6576/product_data_sheet0900aecd805 82763.html. OL-19587-01 SFP and SFP+ Transceiver Specifications Cisco MDS 9500 Series Hardware Installation Guide C-35...
Page 248
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
MGMT 10/100 Ethernet Port, page D-6 • Supported Power Cords and Plugs, page D-7 • Cables and Adapters Provided The Cisco MDS 9500 Series accessory kit includes the following items: • RJ-45 rollover cable DB-9F/RJ-45F PC—RJ-45 to DB-9 female DTE adapter (labeled “Terminal”) •...
RJ-45/DSUB F/F adapter or the DB-9F/RJ-45F PC terminal adapter to connect the console port to a computer running terminal emulation software. Console Port Pinouts Table D-1 lists the pinouts for the console port on the Cisco MDS 9500 Series. Table D-1 Signal 1. Pin 1 is connected internally to pin 8.
COM1 Port Pinouts Table D-4 lists the pinouts for the COM1 port on the Cisco MDS 9500 Series. Note Additional cables and adapters can be ordered from your customer service representative.
RJ-45, straight-through UTP cable to connect the management port to an external hub, switch, or router (see Figure D-1 1 Pin 1 Cisco MDS 9500 Series Hardware Installation Guide COM1 Port Pinouts (continued) Port Mode Signaling and Pinouts for Modem with DB-25 Connection DB-9F/RJ45F...
Table D-7 Signal RD– Not used Not used Not used Not used Cisco MDS 9500 Series Hardware Installation Guide RJ-45 Interface Cable Connector RJ-45 (both ends) 2 Pin 8 10/100BASE-T Management Port Cable Pinout (MDI) Appendix D Cable and Port Specifications...
Only the regular power cords or jumper power cords provided with the switch are supported. Note Table D-8 lists the power cords for the Cisco MDS 9500 Series switches and provides their lengths in feet and meters. Table D-8 Description...
Page 256
Power Cord, 250VAC 13A KSC8305 Plug, Korea Power Cord, 250VAC 15A CNS10917-2 Plug, Taiwan Cabinet Jumper Power Cord, 250VAC 16A C20-C19 Connectors Cisco MDS 9500 Series Hardware Installation Guide Power Cords for the MDS 9500 Series Switches (continued) Appendix D Cable and Port Specifications Length Feet Meters 13.65...
(6000 W, 3000 W, 2500 W, and 1900 W) 23 G SEV 1011 (16 A) 6 South Africa (6000 W, 3000 W, 2500 W, and 1900 W) EL 208, SABS 164-1 (16 A) Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs...
Page 258
Figure D-7 1 NEMA 5-20P North American power cord product ID: CAB-7513AC 110 VAC (20 A) Cisco MDS 9500 Series Hardware Installation Guide D-10 Additional Power Supply Plug Supported for 1900-W Only Figure D-7 at 110 VAC results in 1300 W available to the system.
C19 and C20 connectors on the optional jumper power cord for the Cisco MDS 9500 Series. The C19 connector plugs into the C20 inlet on the Cisco MDS 9500 Series power supply, while the C20 connector plugs into the C19 receptacle of a power distribution unit for a cabinet.
Locale North America/Japan US/Japan Australia China Switzerland Continental Europe Cabinet Jumper Power Cord Cisco MDS 9500 Series Hardware Installation Guide D-12 Power Supply AC Power Cords Power Cord Part Number Source Plug Type CAB-9K2A-NA NEMA 5-20 CAB-9K16A-US2 NMEA L6-20 CAB-9K16A-AUS...
Length: 14 ft 0 in. (4.26 m) CAB-9K16A-US2 Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: IEC 60320 C19 Connector: IEC 60320 C19...
Page 262
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Figure D-12 Plug: AU20S3 Figure D-13 Figure D-14 Plug: SEV 5934-2 Cisco MDS 9500 Series Hardware Installation Guide D-14 CAB-9K16A-AUS Cordset rating: 16 A, 250 V Length: 14 ft 0 in. (4.26 m) CAB-9K16A-CH...
Page 263
CAB-9K16A-EU Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) CAB-C19-CBN Plug: IEC 60320 C20 Cisco MDS 9500 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: IEC 60320 C15 Connector: IEC 60320 C19 D-15...
Page 264
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...
If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you Note purchased support directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtm OL-19587-01 A P P E N D I X “Finding the Chassis Serial Number” section on page Cisco MDS 9500 Series Hardware Installation Guide E-2.
In later releases of the Cisco MDS 9509 Director, the chassis serial number label was moved, as shown Figure E-2. Earlier releases may have the serial number label on the right side instead of the left. Cisco MDS 9500 Series Hardware Installation Guide OL-19587-01...
Page 267
The Cisco MDS 9506 Director chassis serial number label is shown in Figure E-3 SN: AAANNNNXXXX OL-19587-01 Serial Number Location on Cisco MDS 9509 Director Serial Number Location on Cisco MDS 9506 Director Cisco MDS 9500 Series Hardware Installation Guide Contacting Customer Service Figure E-3.
Planning the location and layout of your equipment rack or wiring closet is essential for successful switch operation, ventilation, and accessibility. recommends completing before installing the Cisco MDS 9500 Series. Consider heat dissipation when sizing the air-conditioning requirements for an installation. See Table C-1 on page C-1 MDS 9513 Director”...
Page 269
4. RFI = radio frequency interference OL-19587-01 Site Planning Checklist (continued) Verified By Cable type Connector type Cable distance limitations Interface equipment (transceivers) evaluation: Distance limitations for signaling Site wiring levels Cisco MDS 9500 Series Hardware Installation Guide Site Preparation Checklist Time Date...
Floor location Address (line 1) Address (line 2) City State Zip code Country Cisco MDS 9500 Series Hardware Installation Guide (Table E-2) to record contact and site information. Contact and Site Information Appendix E Site Planning and Maintenance Records OL-19587-01...
Modem telephone number Table E-4 Slot Module Type Supervisor OL-19587-01 (Table E-3 Table Network-Related Information Module Information Module Serial Number Cisco MDS 9500 Series Hardware Installation Guide Chassis and Module Information E-4) to record information about the chassis and Notes...
Page 272
Slot Module Type Supervisor Slots 7, 8, and 9 are only available in the Cisco MDS 9509 Director. Note Cisco MDS 9500 Series Hardware Installation Guide Module Information (continued) Module Serial Number Appendix E Site Planning and Maintenance Records Notes...
Page 281
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m description 1-56, C-19 installing 3-11 removing 3-11 supported (table) C-20 Cisco MDS 9500 Series Hardware Installation Guide IN-9 OL-19587-01...
Page 282
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m Cisco MDS 9500 Series Hardware Installation Guide...