Table of Contents

Advertisement

FORCE / 3
T roubleshooting
Problem
Agitator does not operate
.
3.0 & 4.0 DP
Cause
Power cord is not receiving
electricity
Loose power cord and or
extension cord.
(Electrical panel) Rocker switch
is not in the "on" position.
Jam of material between
the blade of the agitator
and airlock or sidewall.
Start capacitor failure on
agitator motor.
Main panel rocker switch
for agitator motor has failed
Loose wire inside electrical
system.
Loose wire at electrical
terminal strip.
23
Remedy
Check circuit breaker or
fuse box at electrical
source.
Check to make sure all
cord ends are in good
physical condition and
are in good electrical
condition.
Depress rocker switch on
electrical panel to the
"on" position.
Disconnect electrical
from power source.
Remove material in
hopper, locate jam
and/or remove foreign
object.
Have capacitor replaced
by a qualified
technician. Call Intec for
nearest service center
location.
Replace with original
factory part rocker
switch.
Have the system
inspected by a qualified
technician. Call Intec for
nearest service center
location.
Pull test all wires and
tighten all screws.

Advertisement

Table of Contents