Troubleshooting - Intec FORCE/2 HP Instruction Manual

Insulation blowing machine
Hide thumbs Also See for FORCE/2 HP:
Table of Contents

Advertisement

Troubleshooting

Problem
Machine does not turn on.
Blower does not run.
T: 303-833-6644
Original Language - English
Power cord connection is loose.
Power cord not connected at
machine or power source.
Machine's circuit breaker has
tripped.
Circuit breaker at power source
has tripped.
Electrical system may have a
loose wire.
Wired remote plug not placed in
electrical panel's wired remote
receptacle.
Wired remote cord & electrical
panel switches need to be in the
correct position for the machine
to turn on.
Blower's circuit breaker needs to
be reset.
Worn brushes in blower motor.
800-666-1611
or
Likely Cause
Instruction Manual
Remedy
Ensure appropriate power cord
connection at machine.
Ensure appropriate power cord
connection at power source.
Connect power cord.
Reset circuit breaker(s).
Reset circuit breaker.
Have the system inspected by a
qualified technician.
Plug the wired remote's plug
into the electrical panel's
receptacle if operating the
machine in wired remote
setting.
Ensure that the Power Button
has been pressed and the Power
Button's LED is illuminated
green. Place the remote's
blower switch on the wired
remote in the 'ON' position;
place the remote's agitator
switch on the wired remote in
the 'ON' position. Ensure the
rotary control switch is in the
correct position for the
operator's desired control
method.
Blower circuit breaker is a small
push button. There should not
be any white showing on the
circuit breaker.
Have a qualified technician
replace blower brushes or
replace blower motor.
www.inteccorp.com
|
13