Intec FORCE 3 Instruction Manual page 27

Table of Contents

Advertisement

FORCE / 3
T roubleshooting, Cont.
Problem
Agitator does not operate
Machine makes a ratchet-
ing noise when turned on.
3.0 & 4.0 DP
Cause
Remote box/cord switch
failed and or remote cord
wire (conductor) has failed.
Contactor coil (inside
electrical) failed
Bolt on agitator is missing
or has sheared off.
Sprockets out of alignment.
Low voltage, contactor
chattering.
24
Remedy
Disconnect electrical from
power source. Using a volt-
meter test switch for conti-
nuity, if switch is good
check each individual con-
ductor in remote cord.
Replace failed component
with original factory part.
Have the system inspected
by a qualified technician.
Call Intec for nearest service
center location.
Remove insulation; locate
9/16 bolt head located on
the outside of the agitator
assembly. If bolt is missing
align the hole in agitator to
the shaft and insert new
3/8*16 bolt (grade 5 or
better) into threaded area.
Tighten bolt-using wrench. If
bolt has sheared off, locate
bolt in shaft, drill hole in
bolt and use easy out to
remove. Easy out is a trade
name for a device that
assists the removal of bolts.
It can be purchased at
many hardware stores or
car automotive store.
Locate set screws on sprock-
et(s), loosen set screw (one
full turn), re-align sprock-
ets, tighten set screws
before operation.
Relocate power cord to
another electrical outlet. If
additional extension cords
are be used, move machine
closer to power source and
use the supplied power cord
which came with the
machine.

Advertisement