Intec FORCE 3 Instruction Manual page 30

Table of Contents

Advertisement

FORCE / 3
T roubleshooting Cont.
Problem
Agitator trips circuit
breaker at main panel.
Blower trips circuit break-
er at power source.
Operator in attic keeps
getting shocked.
3.0 & 4.0 DP
Cause
Low voltage.
Incorrect size extension
cord.
Forcing material into
hopper.
Wet insulation (recycled)
material in hopper.
Worn or frozen agitator
airlock bearing.
Low voltage, caused by
insufficient sized wire to
outlet.
Low voltage.
Incorrect extension cord.
Static electricity buildup
from insulation.
27
Remedy
FORCE/3 requires a mini-
mum of 36 amps @115V.
Relocate power cord(s) to
20 amp circuit(s).
For an additional 50', use
10/3 cord. For 100' use
8/3 cord.
Do not push down on insu-
lation while filling hopper.
See page 16 for further
information. Use a 50/50
mix of we to dry material.
Have bearing checked and
replaced by a qualified
technician.
Use generator no smaller
than 12.5 KW. Consult
factory for proper sizing.
Blower requires a minimum
of 20 amps @ 115V. Use a
dedicated refrigerator outlet
or equivalent.
For an additional 50', use
10/3 cord. For 100' use
8/3 cord.
Mix half and half solution
of water and fabric softener.
Mist insulation while load-
ing hopper. Note: excess
moisture will cause jam-
ming.