We take pride in making your job as easy and profitable as possible. The right system for your needs: Intec strives to provide you with the best combination of portability, functionality, and installation versatility to surpass your desired success. From lightweight...
HOW THE SYSTEM WORKS .................. 4 SYSTEM SET-UP: ....................5 SYSTEM OPERATION: ..................7 MAINTENANCE ....................10 ................11 INTEC QUICK-ACCESS - IQ TROUBLESHOOTING ..................13 SPECIFICATIONS ..................... 16 ELECTRICAL DRAWING ..................17 MAKING A CLAIM FOR DAMAGE OR LOSS ..............18 WARRANTY ....................
netzerotools.com TURBO FORCE Instruction Manual Symbols SYMBOL SYMBOL MEANING Indicates an imminently hazardous situation, which, if not avoided, Danger will result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Warning could result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Caution may result in minor or moderate injury.
netzerotools.com TURBO FORCE Instruction Manual How the System Works OVERVIEW: Cellulose, Fiberglass, or Stone Wool insulation is loaded into the hopper. The insulation goes thru or under the Breaker Bar. The agitator breaks-up and conditions the insulation for proper density while also sweeping the insulation into the airlock. The airlock transports the insulation into the airstream created by the blower system.
netzerotools.com TURBO FORCE Instruction Manual Set up and Operation System Set-Up: Set system on a dry, level surface. 1. Obtain appropriate protective equipment. 2. Attach hose to machine outlet using a hose clamp. Suggested slide 3. Open slide gate & place pin in desired opening. gate settings for desired applications...
Page 7
netzerotools.com TURBO FORCE Instruction Manual 5. Place the Loading Platform in down position by first lifting up, then rotating downwards to rest on top of the system’s handle. 1. Lift Loading 2. Rotate downwards Platform up. to rest on system’s handle.
Page 8
netzerotools.com TURBO FORCE Instruction Manual Fiberglass or Stone Wool: 2. Bend bag to 3. Place ½ bag on loading platform with 1. Cut bag in ½ all the break. open end facing towards a side & not way around. into the hopper. Turn machine on. Slice wrapper in direction shown to allow product to expand into hopper.
netzerotools.com TURBO FORCE Instruction Manual System Operation: 1. Energize System a. Place Primary Blower Circuit Breaker in the ‘on’ position. b. Place Agitator Circuit Breaker in the ‘on’ position. c. For those having the hP3 system: If you desire to use the auxiliary blower, place Aux Blower Circuit Breaker in the ‘on’...
Page 10
netzerotools.com TURBO FORCE Instruction Manual i. Note: It is typical to place the Auxiliary Blower Circuit Breaker in the ‘off’ position when using the Variable Speed. b. Adjust the Variable Speed Setting to desired setting ranging from 100% to near 0%. Note 1: To obtain maximum blower velocity and pressure, place the Variable Speed control in the off position.
Replace airlock seals if a cut or tear is evident. Airlock seals should be replaced every 300 hours of operation, or once per year. Visit www.inteccorp.com or contact Intec for replacement instructions. Chain Clean and lubricate the chain once per year.
unexpected repairs are required at times. Making these activities as easy & efficient as possible -- so you can get back up and running in the quickest of manners -- is why Intec Quick-Access was developed. IQ was designed to further your efficiencies by reducing the time it takes to access critical system components.
Page 13
netzerotools.com TURBO FORCE Instruction Manual Chains Removing the access panel provides access to the chain driving the two agitators. The airlock chain is accessed thru the revolutionary tilt-back design. Electrical Components Opening the electrical panel provides access to the electronics controlling your TURBO FORCE.
‘off’ or ‘on’ position. Blower contactor overload Let system cool. If happens activated. often, contact Intec for settings. Worn brushes in blower motor. Have a qualified technician replace blower brushes or replace blower motor. Agitator does not run.
Page 15
netzerotools.com TURBO FORCE Instruction Manual Problem Likely Cause Remedy Machine is on, yet no material Slide gate is closed. Open slide gate. comes out of hose. Insulation blockage in hose. Turn system off, remove hose and clear blockage. Blower is off. Turn blower on.
Page 16
netzerotools.com TURBO FORCE Instruction Manual Problem Likely Cause Remedy Insulation exiting hose is Heavy insulation material. Push slide gate in 1-2 holes. dribbling out. Turn on Auxiliary Blower. Kink in hose. Straighten hose. Airlock seal is worn. Inspect airlock seals for cuts and wear.
netzerotools.com TURBO FORCE Instruction Manual Specifications Weight 385 lbs 175 kg Blower 115 VAC, 14.3 amp, single stage Agitator Motor ½ HP, 115VAC, 7.8 amp Airlock Motor ½ HP, 115VAC, 7.8 amp Power Requirements 2-115VAC, 60 Hz, 15 amp circuits for standard 3-115VAC, 60 Hz, 15 amp circuits for hP (1311mm) (1562mm)
TURBO FORCE Instruction Manual Making a Claim for Damage or Loss Your Intec products were carefully packed and thoroughly inspected before leaving our factory. We understand that damage to or defects with your system may unfortunately occur. Please inspect your shipment carefully upon arrival and save the shipping containers and packaging materials in case of damage.
It is expressly understood and agreed that no officer, agent, salesman or employee of the manufacturer Intec (MANUFACTURER) has the authority to obligate the MANUFACTURER by any terms, stipulations, or conditions not herein expressed; that all previous representations and agreements, either verbal or written, referring to the machinery and equipment, which is the subject of this Warranty, are hereby superseded and canceled, and that there are no promises or agreements outside of the Warranty agreement.