Intec FORCE 3 Instruction Manual page 24

Table of Contents

Advertisement

3.0 & 4.0 DP
FORCE / 3
Maintenance, Cont.
CHAIN TENSIONER
The chain tension between the
agitator and the airlock rotor
is self-adjusting and should
never need maintenance.
GEARBOX
The gearbox is sealed for life and should not
require any maintenance. Periodically remove
buildup of insulation dust from gearbox case to
prevent overheating and ensure trouble free life.
BLOWERS
Keeping the blowers clean will
help reduce the likelihood
of overheating. Overheating
will cause damage to the
bearings and motor
windings. The blowers have
two filters, The air intake is
for cooling the motor and is
located on top of the motor
the vacuum fan intake is
located on the underneath
side of the machine. and
has a metal filter to protect the fan blade from picking up large particles of
insulation.. The motor filter should be cleaned twice a week, using
compressed air to remove dust or wash in water and dry before using. It
is recommended that the motor filter be changed every month. The filters
(which are knee high panty hose) can be purchased at any local grocery
store. The (vacuum fan filter) vacuum filter is located on the underneath
side of the frame and should be cleaned weekly. Vacuum fan filter, reach
underneath the blower mounting plate and locate the frame of the metal
filter, push outer edge of frame towards airlock until it stops, pull down
on filter to remove. To clean, use soap & water and allow to dry for 24
hours or use compressed air to blow out.