Operating With a Generator /

Using Additional Extension Cords

USING A GENERATOR:
Both the Force/3 3.0 & 4.0 DP operate best when using a use a
commercial sized generator. The start up requirement for both Force/3
machines is 10.5KW. Normal running wattage for the Force/3 3.0 is
4025 watts and the 4.0 DP is 4680 Watts. We recommend using a
minimum wattage of 10.5KW. While many brand name generators
(Honda, Generac, Yamaha, Coleman) are of high quality, they are not
commercial grade and are not built to handle the high in-rush current
that is needed to start the agitator motor.
Consult Intec for further information or your local generator reseller.
Using a generator of insufficient size will cause internal motor damage
and will void machine warranty.
FORCE/3 MOTOR SPECIFICATIONS:
Blower 5.7 diameter
Blower 7.2 diameter
GE
(model C371)
Leeson
(model 110420.00)
ADDITIONAL EXTENSION CORDS:
The FORCE/3 is supplied with the correct size power cords to deliver
the proper voltage to the motors. If you require additional extension
cords please follow the table on page 18. A smaller sized extension
cord is not advised and will lead to electrical or motor failure.
3.0 & 4.0 DP
10.2 Amps @ 115 Volt x 2 blowers = 20.4 Amps
13.0 Amps @ 115 volt x 2 blowers = 26 Amps
14.7 Amps @ 115 Volt
17.2 Amps @ 115 Volt