T roubleshooting, Cont.
Problem
Blower does not operate
3.0 & 4.0 DP
Cause
Blower switch on main
panel is "off".
Blown fuse.
Remote switch for blower
motor has failed.
Loose power cord/extension
cord at electrical system.
Loose wire in electrical
system.
Worn brushes in blower
motor.
Worn brushes on blower
motor.
Connection between blower
housing and airlock
leaking.
26
Remedy
Depress switch to "on", use
remote box switch to
operate.
Remove panel below electri-
cal control. Locate blower
fuse(s) and replace with 15-
amp slo blo type fuse.
Replace with original
factory part.
Check condition of electrical
plug.
Have the system inspected
and repaired by a qualified
technician See page 23 of
this manual for further
instructions.
Have the brushes inspected
and replaced by a qualified
technician.
Replace all brushes on both
blower motors.
Check hose clamps, if loose,
tighten.