Whenever the pellet container and the auger(s) become completely empty, the stove will be
automatically switched off. Upon the next ignition, you must load pellets onto the auger (see 5.7).
We recommend that you install a smoke detector in the room where the stove is installed.
It is recommended to let the stove burn empty for pellets and clean it before a still stand period
longer than 2 weeks – especially if the humidity is high.
A yearly service visit is obligatory and crucial to the functioning and safety of the stove (see 8.4).
ATTENTION! If the stove is not installed properly, power outages may result in fume
spillages. Under specific circumstances, an uninterrupted power supply unit must be
installed.
Aduro A/S declines all responsibility for any damage which may be caused, directly or indirectly, to persons,
animals, or objects as due to non-compliance with any provision specified in the manual, especially warnings
regarding installation, use, and maintenance of the stove.
The responsibility for improper use of the product is entirely borne by the user and relieves the manufacturer
from any civil and criminal liability. Tampering or unauthorized replacement with non-original spare parts
could be hazardous for the operator's safety and relieves the company from any civil and criminal liability.
Power
Dimension (HxWxD)
Weight
Fuel (dimension)
Exhaust / Inlet
Draft
Pellet container capacity
Voltage
Frequency
Electrical power during the operation
Electrical power during the initialization
Maximal efficiency
Nominal use of pellet
Minimal use of pellet
CO emission reduced on 13%
Maximal exhaust gas temperature
Dust content
Mass flow
Operating temperature
Storage temperature
Flamme verte class
Energy Efficiency Index (EEI) / Class

2. Technical specifications

3,4 kW
6,8 kW
120 x 50 x 56 cm
120 kg
Wood pellets (Ø6 mm L30 mm)
Ø80 / Ø50 mm
12±2 PA
14 kg
230V ± 15%
50 Hz
37 – 81W
400 – 460W
>=87%
>87%
0,8 kg
1,6 kg
0,8 kg
<0,02%
<0,02%
128°C
176°C
3
<20 mg/m
<20 mg/m
4,6 g/s
5,2 g/s
10 - 60°C
max 65°C

122,8 / A+
3
41