RT9150E SERVICE MANUAL
4.
Unscrew the switch ¾ turn, which equals 0.75 mm (0.03
in). The distance between the switch and rack should be
0.5 to 1.0 mm (.02 to .04 in) as shown in Figure 2-53.
5.
Tighten the locknuts.
6.
Use an ohmmeter to check for proper operation of the
switch while cycling the cylinder, to locked and unlocked.
7.
Repeat, as necessary, for the left proximity switch on the
other cylinder.
Adjustment for Switch 2
1.
Use the ECOS System to unlock the cylinders.
2.
Loosen the locknuts on the right proximity switch (2,
Figure 2-53).
GROVE
3.
Screw the proximity switch in until it contacts the rack.
4.
Unscrew the switch ¾ turn, which equals 0.75 mm (0.03
in). The distance between the switch and rack should be
0.5 to 1.0 mm (.02 to .04 in) as shown in Figure 2-53.
5.
Tighten the locknuts.
6.
Use an ohmmeter to check for proper operation of the
switch while cycling the cylinder, to locked and unlocked.
7.
Repeat, as necessary, for the right proximity switch on
the other cylinder.