Adding X-zone to a group
1. Position the ungrouped X-zone 5000 next to the main
device.
2. Press the
key on the main device to open the menu.
OK
3. Select and confirm
.
4. Select and confirm
group devices.
Display on main device:
Grouping LED:
red-green flashing slowly.
Display on the group device:
Grouping LED:
green flashing slowly.
5. Press the
key on the required group device to add the
OK
X-zone to the group.
Grouping LED group device: lit in green.
6. Press the
key on the main device to end the search
OK
process.
Grouping LED main device: lit in red-green.
Grouping is completed.
7. Deactivate group monitoring provisionally (see chapter
4.2.7 on page 46).
8. Set up new group device at the location of use.
Dräger X-zone 5000
to start the search process for
1:55
2
05233112.eps
03933112.eps
4.2.5
Remove X-zone from a group
NOTICE
i
i
If the last group device is removed from the group, the
whole group is terminated automatically.
1. Deactivate group monitoring provisionally (see chapter
4.2.7 on page 46).
2. Position group device to be removed next to the main
device.
3. Press the
key on the main device to open the menu.
OK
4. Select and confirm
.
5. Select and confirm
Display on main device:
Grouping LED:
red-green flashing quickly.
Display on the group device:
Grouping LED:
green flashing quickly.
6. Press the
key on the group device to be removed to
OK
remove the X-zone from the group.
Grouping LED on removed group device: off.
7. Press
key on the main device.
OK
Grouping LED main device: lit in red-green.
Grouping is completed.
Establishing a wireless connection
.
1:55
2
#1
04133112.eps
04233112.eps
45