Maintenance

Compressor Lubrication

Portable Compressor Fluid Chart

Refer to these charts for correct compressor fluid required. Note that the selection of fluid
is dependent on the design operating pressure of the machine and the ambient
temperature expected to be encountered before the next oil change.
Design Operating Pressure
100 psi to 300 psi
100 psi to 300 psi
350 psi
500 psi
22221949
Ambient Temperature
-10° F to 125° F
(-23° C to 52° C)
-40° F to 125° F
(-40° C to 52° C)
-10° F to 125° F
(-23° C to 52° C)
65° F to 125° F (18° C to 52° C)
-40° F to 65° F
(-40° C to 18° C)
50° F to 125° F (10° C to 52° C)
10° F to 65° F (-12° C to 18° C)
below 10° F (-12° C)
Operation & Maintenance Manual
Specification
IR Pro-Tec™
Mil-PRF 2104G
SAE 10W
IR Performance 500
Mil-L-46167
IR XHP 505
IR XHP1001
IR Performance 500
Mil-L-46167
IR XHP1001
IR XHP 505
Consult Factory