SECTION 4
4.5

SHUTDOWN PROCEDURE

1. Close the service valve.
2. Place the <ON> switch in the "off" position.
The following message will be displayed in
the LCD graphic display:
3. The unit will continue to run, though it will not
produce usable air. At the end of the cool
down cycle, the engine will be shut down.
The controller will stay powered up, and a
new message will be displayed:
600H, 700HH, 750, 750H, 750HH, 825, 900H, 1050 USER MANUAL
The controller will continue to monitor the
system pressures and will not power down
until all pressures drop below 10 PSI (0.7
bar). This final process may take 3 to 5 min-
utes. Operator interaction is not necessary
during this time as the controller will auto-
matically disconnect power to all systems so
that the battery is not inadvertently drained
after shutdown.
WARNING
The E-Stop (emergency stop switch) should
be used only in the event of an emergency.
Refrain from using the E-Stop to shut the
machine down during normal operations.
All usage of the E-Stop is logged in perma-
nent memory for use by service technicians
when troubleshooting a machine. Non-
emergency use of E-Stop is considered
equipment abuse and could void the manu-
facturer's warranty.
73