Subsequent Start-Up Procedure; Shutdown Procedure - Sullair 12 Series Operator's Manual

40, 50, 60 and 75 hp industrial rotary screw air compressor
Table of Contents

Advertisement

7. Observe the operating temperature. If the oper-
ating temperature exceeds 200_F (93_C), the
cooling system or installation environment
should be checked.
8. Observe return line sight glass and maintenance
indicators.
9. Open shut---off valve to service line.
10. Reinspect the compressor for temperature and
leaks the following day.
5.4 SUBSEQUENT START-- UP PROCEDURE
On subsequent start ---ups, check that the proper
level is visible in the fluid sight glass and simply
press the START button. When the compressor is
running, observe the instrument panel and mainte-
nance indicators.

5.5 SHUTDOWN PROCEDURE

To shut the compressor down, simply press the
STOP button.
Section 5
OPERATION
19