To set up Wi-Fi manually:
1. Enter the network name.
2. Choose the security level.
3. Enter the password.
4. Press the confi rm button to connect to the Wi-Fi
connection. The product attempts to connect to
the selected network.
5. If connection is successful, a confi rmation
screen appears. Press the confi rm button to
return to the menu.
DATE/TIME SETUP
1. From the [Date/Time Setup] screen, choose the
date.
a. With [dd] highlighted, choose the day. Press the
confi rm button.
b. With [mm] highlighted, choose the month. Press
the confi rm button.
c. With [yy] highlighted, choose the year. Press the
confi rm button.
2. Choose the time.
a. With [--:] highlighted, choose the hour. Press the
confi rm button.
b. With [:--] highlighted, choose the minute. Press
the confi rm button.
3. Press the confi rm button.
MOWING ZONES
MOWING ZONE A
■
Mowing Zone A has a basic lawn layout. The lawn is
free from obstacles.
■
The robotic lawn mower can move unobstructed
from one point to another.
■
Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE B
■
Mowing Zone B has a basic lawn layout, with
obstacles.
■
The lawn is the same size as Mowing Zone A
but uses 50% more wires due to the number of
obstacles.
■
Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■
The gap between an obstacle and the perimeter
should be 90 cm minimum.
■
The gap between each obstacle should be 90 cm
minimum.
■
Lay the wire 45 cm away from the obstacles.
■
Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE C
■
Mowing Zone C has an L-shaped lawn layout, with
obstacles.
■
Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■
The gap between an obstacle and the perimeter
should be 90 cm minimum.
■
The gap between each obstacle should be 90 cm
minimum.
■
Lay the wire 45 cm away from the obstacles.
■
Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE D
■
Mowing Zone D has a U-shaped lawn layout, with
obstacles.
■
The two sides of the lawn are connected by a
narrow passage.
■
The narrow passage should have a width of 90 cm
minimum.
■
Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE E
■
Mowing Zone E has an irregularly shaped lawn
layout, with a narrow passage in between.
■
The lawn has obstacles but has an open perimeter
(no obstacles around edges).
■
Parallel wires to and from each obstacle should
have a gap of less than 5 cm between each wire.
■
The gap between an obstacle and the perimeter
should be 90 cm minimum.
■
The gap between each obstacle should be 90 cm
minimum.
■
Lay the wire 45 cm away from the obstacles.
■
Lay the wire 45 cm away from the house.
■
Lay the wire 10 cm away from open perimeter, or
any level paving stones around the house.
MOWING ZONE F
■
Mowing Zone F has split lawns, with a narrow
passage in between.
■
Both lawns are free from obstacles.
■
The narrow passage should have a width of 90 cm
minimum.
■
Lay the wire 45 cm away from the obstacles.
■
Lay the wire 45 cm away from the perimeter edge.
MOWING ZONE G
■
Mowing Zone G has split lawns (Lawn A and Lawn
B).
■
The lawns are separate, with an obstacle in
between but with parallel wires connecting Lawn A
to Lawn B.
EN
SV
DA
NO
FI
DE
FR
ES
IT
PT
NL
RU
PL
HU
CS
RO
SK
HR
ET
LT
LV
SL
BG
TR
UK
17