Fig. 11 shows the overhead view of the boiler with the reference
measurements for the centre points of the fumes outlets and
the comburent air inlet holes for the boiler support plate.
CONCENTRIC OUTLETS (ø 60-100)
Clamp
Concentric
outlet
9
.
TABLE 1
WATER TANK DESCRIPTION
Water tank type
Water tank disposition
Exchanger disposition
DHW contents
Coil contents
Exchange surface
Selection field of DHW temperature
Flow regulator
Hot water quantity drawn in 10' with ∆t 30 °C
Water tank maximum pressure
Condensate
collector
Condensate
drain trap
14
TECHNICAL DATA
8
COMPULSORY CONDENSATE
COLLECTOR
Temperature of installation site (°C)
TWIN OUTLETS (ø 80)
Condensate
collector
Air intake
duct
Fumes
outlet duct
Air intake
duct
24kW
Inox steel
Vertical
Vertical
l
60
l
3,87
m
2
0,707
°C
40 - 63
l/min
10
l
158
bar
8
13
Condensate
drain trap
Condensate
collector
Fumes
outlet duct
Condensate
drain trap
28kW
Inox steel
Vertical
Vertical
60
3,87
0,707
40 - 63
12
175
8