Ariston NIMBUS COMPACT S NET Manual page 89

Table of Contents

Advertisement

Available languages

Available languages

DESCRIPTION
17
3
9
Floor drying Flow Set Point T
17
4
Cooling
17
4
0
Cooling mode activation
17
4
1
Cooling anticycling time
17
4
2
DeltaT_HP_Flow_Comp
17
5
Domestic Hot Water
17
5
0
DHW Comfort Setpoint T
17
5
1
DHW Reduced Set Point T
17
5
2
Comfort Function
17
5
3
Max HP charging time
17
5
5
Antilegionella start time [hh:mm]
17
5
6
Thermal Cleance Cycle frequency
17
6
Manual Mode - 1
17
6
0
Manual mode activation
17
6
1
HP circulator control
17
6
2
Diverter valve control
17
6
3
Diverter valve COOLING
17
6
4
Auxiliary circulator
17
6
5
Output AUX 1/2 contact
17
6
6
Test resistance 1
17
6
7
Test resistance 2
17
6
8
Test resistance 3
17
6
9
Anode output
17
7
Manual Mode - 2
17
7
0
Manual mode activation
17
7
1
Force Hp Heat
17
7
2
Force Hp Cool
17
7
3
Rating heating mode
17
7
4
Rating cooling mode
17
7
5
Compressor frequency setting
17
7
6
Fan 1 rpm setting
17
7
7
Fan 2 rpm setting
17
8
Test & Utilities
17
8
0
Air-purge function
17
8
1
Floor drying cycle
17
8
2
Floor drying total Remaining Days
RANGE
25 ÷ 60°C
Cooling not active
Cooling active
0 -10 min.
-10 ÷ 0°C
35 ÷ 65°C
35°C - Par. 15.5.0
Disabled
Time based
Always Active
HC-HP
HC-HP 40°C
Green Mode
30 ÷ 240 min.
[00:00-24:00]
1 ÷ 30 days
OFF - ON
OFF
Low Speed
High Speed
DHW
CH
CH
COOLING
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
18 ÷ 120 Hz
0 ÷ 1000 rpm
0 ÷ 1000 rpm
OFF - ON
OFF
Functional Heating
Curing Heating
Functional Heating + Curing Heating
Curing Heating + Functional Heating
Manual
DEFAULT
55°C
Cooling not active
0 min.
0°C
55°C
35°C
Green Mode
120 min.
01:00
30 days
OFF
OFF
DHW
CH
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
30 Hz
0 rpm
0 rpm
OFF
OFF
only read
89 / GB