DESCRIPTION
17
1
0
HV Input 1
17
1
1
HV Input 2
17
1
2
HV Input 3
17
1
3
AUX Input 1
17
1
4
AUX Output 1 (AFR)
17
1
5
AUX Output 2
17
1
6
AUX P2 circulator setting
17
2
Energy manager parameter 1
17
2
0
Hydraulic scheme
17
2
1
Thermoregulation
17
2
2
ECO / COMFORT
17
2
3
FlowT HP Offset
17
2
4
Boost Time
17
2
5
External temperature correction
17
2
6
Active Resistance Stages
17
2
7
Pro-Tech anode active
17
2
9
Antiblocking pump enable
17
3
Central Heating
17
3
0
CH pump prerun time
17
3
1
Time for prerun new attempt
17
3
2
CH Pump Overrun
17
3
3
Pump Speed Control
17
3
4
Delta T Pump Setpoint
17
3
5
Min Pressure
17
3
6
Warning Pressure
17
3
7
Max PWM Pump
17
3
8
Min PWM Pump
88 / GB
RANGE
Not Defined
Absent
EDF
SG1
External switch off signal
Not Defined
Absent
DLSG
SG2
External switch off signal
Not active
PV Integration Active
None
Humidistat sensor
None
Fault alarm
Humidistat alarm
External heat request
Cooling request
None
Fault alarm
Humidistat alarm
External heat request
Auxiliary circulator
Cooling circulator
Buffer circulator
None
Plus
Compact
Flex
Hp Water Heater
Light (NOT USED)
Absent
Present
Eco Plus
Eco
Average
Comfort
Comfort Plus
0 ÷10°C
0 ÷ 60 min
- 3; + 3°C
1 Stage
2 Stages
3 Stages
OFF - ON
OFF - ON
30 ÷ 255 sec.
0 ÷ 100 sec.
0 ÷ 16 min.
Low speed
High speed
Modulating
5 ÷ 20°C
0,3 ÷ 0,4 bar
0,4 ÷ 0,8 bar
min PWM ÷ 100%
20% ÷ max PWM
DEFAULT
Absent
Absent
Not active
None
None
None
Auxiliary circulator
None
Present
Average
2°C
16 min.
0°C
2 Stages
OFF
ON
30 sec.
90 sec.
3 min.
Modulating
5°C
0,4 bar
0,6 bar
100%
40%