Power supplies of the indoor and the outdoor units are to be respectively connected to a Residual Current operated Circuit-Breaker
(RCCB) with threshold of 30mA. For inverter driven units (outdoor unit), It is advisable the use of type B residual current device for 3Ph
power supplies and type B or F for 1Ph power supplies (depending on the electrical system to which it is connected). For the units
without inverter, (indoor units) a type A Residual current device is sufficient. The type of connection must in any case be carried out in
a workmanlike manner by qualified personnel in compliance with the national regulations in force.
INTERNAL UNIT
Electrical supply
Admitted voltages field
Rated power input
Max current
Cutout - Circuit Breaker size
Differential Circuit Breaker size (RCCB)
Supply cable
Wiring signal EDF, AFR, PV
MODBUS cable
Note: To avoid interference problems in the connection between the MODBUS cable from the internal unit to the external unit, use a shielded cable.
68 / GB
FS 40 - 50 S
V - ph - Hz
230 - 1 -50
V
196 ÷ 253
kW
A
19.1
A
25 - C type
mA
Reference
Min. cable section
3G6
Max diameter
[mm]
Recommended cable
3G6
section
Max. diameter
[mm]
mm
2
mm
2
FS 70 S
230 - 1 -50 400 - 3 -50 230 - 1 -50
196 ÷ 253
340 ÷ 440
4
4
19.1
12 - C type
25 - C type
13 - C type
30 - A type
H07RN-F
3G6
5G2.5
18
18
3G6
5G4
18
18
19.9
H05RN-F 2 x 0.75 mm
H05RN-F 3 x 0.75 mm
FS 90 110 S
400 - 3 -50
196 ÷ 253
340 ÷ 440
4
6
6
9.6
30
9.6
12 - C type
32 - C type
13 - C type
3G6
5G2.5
17
18
17
3G6
5G4
18
19.9
2
2