Panasonic DMR-ES45VP Service Manual page 53

Hide thumbs Also See for DMR-ES45VP:
Table of Contents

Advertisement

Error
Reason
No.
07
The recording circuit can not be
operated in REC mode.
08
The recording circuit is operated in
except for REC mode.
09
Serial communication Error between
VHS Microprocessor (IC6001) and
Timer Microprocessor (IC7501).
11
Cylinder clogs during the PLAY mode. VHS mode -
15
S-reel pulse cannot be detected when
a cassette tape is inserted.
(Error of the S-reel system or the
Capstan system.)
16
Detection of the Cylinder lock during
the constant rotation
17
Detection of S-reel lock during the
constant tape running
18
Detection of T-reel lock during the
constant tape running
20
NG1 in the PG Shifter Automatic
Adjustment
(The cylinder rotation is unstable
during the automatic adjustment.)
21
NG2 in the PG Shifter Automatic
Adjustment
(The vertical sync signal is lacked
while over 5 seconds on the alignment
tape.)
Supplementary Data
Data 1
Data 2
Data 3
VHS mode -
Process
No.
VHS mode -
Process
No.
-
-
-
Process
No.
VHS mode Value of S-Reel
Process
Pulse counted
No.
VHS mode Tape position
Process
No.
VHS mode Tape position
Process
No.
VHS mode Tape position
Process
No.
VHS mode -
Process
No.
VHS mode -
Process
No.
Data 4
-
-
-
-
-
-
Number of FG
Number of FG
-
-