Panasonic DMR-ES45VP Service Manual page 42

Hide thumbs Also See for DMR-ES45VP:
Table of Contents

Advertisement

Memory No.
(Error No.)
H01
The cylinder could not be started.
(Error of the cylinder or the cylinder driver.)
H02
The CAP FG could not be detected.
F03
Mechanism lock during without the unloading and the
cassette-up.
F04
Mechanism lock during unloading
F05
S-reel pulse cannot be detected when a cassette tape is
inserted.
(Error of the S-reel system or the Capstan system.)
F06
Mechanism lock during the Cassette-up.
F09
Communication Error between VHS Microprocessor
(IC6001) and Timer Microprocessor (IC7501)
H07
The recording circuit can not be operated in REC mode.
H08
The recording circuit is operated in except for REC mode. Yes
U11
Cylinder clogs during the PLAY mode.
F15
S-reel pulse cannot be detected when a cassette tape is
inserted.
(Error of the S-reel system or the Capstan system.)
H16
Detection of the Cylinder lock during the constant rotation No
H17
Detection of S-reel lock during the constant tape running
H18
Detection of T-reel lock during the constant tape running
F20
NG1 in the PG Shifter Automatic Adjustment
(The cylinder rotation is unstable during the automatic
adjustment.)
F21
NG2 in the PG Shifter Automatic Adjustment
(The vertical sync signal is lacked while over 5 seconds
on the alignment tape.)
Reason
Automatic display
Memory
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmr-es46vp

Table of Contents