Panasonic DMR-ES45VP Service Manual page 35

Hide thumbs Also See for DMR-ES45VP:
Table of Contents

Advertisement

Item
Mode name
Description
Delete the Last
Delete the Last Drive Error
Drive Error
information stored on the DVD
RAM-Drive.
Laser power
Drive state is judged based on
confirmation
difference between laser power
value at shipping and present
laser power value.
Turn on all FL/
All segments of FL and all LEDs
LEDs
are turned on.
S1 signal output
Forcibly superimpose the S1
signal (approx. 4.5V DC) on the
EE chroma signal, and check the
output on the S terminal.
S2 signal output
Forcibly superimpose the S2
signal (approx. 2V DC) on the EE
chroma signal, and check the
output on the S terminal.
FL display
(Remote controller key)
Press [9] [6] in service
mode.
1.
into RAM Drive in service mode.
(Other media are assumed to be non-
correspondence.)
2. Press [4] [4].
If DVD-RAM disc in not
inserted, [NO DISC] is
displayed.
If power value study was
filed, [ERROR] is
displayed.
All segments are turned
Press [5] [1] in service
on.
mode.
Press [5] [2] in service
mode.
Press [5] [3] in service
mode.
Key operation