Magnetek IMPULSE G+ 4 Series Technical Manual page 138

Adjustable frequency/vector crane controls
Hide thumbs Also See for IMPULSE G+ 4 Series:
Table of Contents

Advertisement

Parameter
Display
F01-14
PG2 #Gear Teeth2
F01-15
PG2 Output Ratio
F01-16
PGO-2-H
F01-21
PG Fdbk Loss Sel
0
Decel to Stop
1
Coast to Stop
2
Fast Stop
3
Alarm Only
F01-22
PGO-1-S Det Time
F01-23
PG Overspeed Sel
0
Decel to Stop
1
Coast to Stop
2
Fast Stop
3
Alarm Only
F01-24
PG Overspd Level
F01-25
PG Overspd Time
F01-26
PG Deviation Sel
0
@Spd Agree-Decel
1
@Spd Agree-Coast
2
@SpdAgree-F-Stop
3
@Spd Agree-Alm
4
@Run-Decel
5
@Run-Coast
6
@Run-Fast Stop
7
@Run-Alarm Only
F01-27
PG Deviate Level
F01-28
PG Deviate Time
Function
Sets the gear ratio between the motor shaft and the
encoder (PG).
A gear ratio of 1 will be used if F01-13 or F01-14 are
set to 0.
Sets the division ratio for the pulse monitor.
Delay time for PGO-2-H detection. A setting of 0
disables PGO-2-H detection. Channel 2 is associated
with slot CN5-B.
Stopping method when PGO-1-S or PGO-2-S faults
are detected.
Decelerate to stop using the deceleration time in B05-
02.
Decelerate to stop using the deceleration time in B05-
08.
PGO-1-S (CH1) disconnection detection time. A
setting of zero disables PGO-1-S detection.
Sets the stopping method when an overspeed (OS)
fault occurs.
Decelerate to stop using the deceleration time in
B05-02.
Decelerate to stop using the deceleration time in
B05-08.
Sets the overspeed detection level as a percentage of
the maximum output frequency.
Sets the time in seconds for an overspeed situation to
trigger a fault (oS).
Stopping method at excessive speed deviation.
Stops by deceleration time 1 - B05-02.
Coast to stop.
Decelerates by fast-stop B05-08.
DEV displayed, operation continues.
Stops by deceleration time 1 - B05-02.
Coast to stop.
Decelerates by fast-stop B05-08.
DEV displayed, operation continues
Sets the speed deviation detection level as a
percentage of the maximum output frequency.
Sets the time in seconds for a speed deviation
situation to trigger a fault DEV.
Range
0–1000
1–132
0–100 ms
Traverse: 0–3
NLB: 1
0.0–10.0 sec
Traverse: 0–3
NLB: 1
0–120%
0.0–2.0 sec
Traverse: 0–7
NLB: 5
0–50%
0.0–10.0 sec
®
IMPULSE
•G+ & VG+ Series 4 Technical Manual
Default
0
1
15
1
2.0
1
105
0.0
5
10
0.3
November 2020
Page 138