Alvarado TAS12-AS1 Installation Instructions Manual

Alvarado TAS12-AS1 Installation Instructions Manual

Intelligent admission station

Advertisement

Quick Links

TAS12-AS1 & TAS12P-AS1
INTELLIGENT ADMISSION STATION
TAS12P-AS1
TAS12-AS1
Installation Instructions
Alvarado Manufacturing Company, Inc.
12660 Colony Street, Chino, CA 91710
Telephone: +1 (909) 591-8431
Fax: +1 (909) 628-1403
support@alvaradomfg.com
www.alvaradomfg.com
PUD3677R1-0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAS12-AS1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alvarado TAS12-AS1

  • Page 1 TAS12-AS1 & TAS12P-AS1 INTELLIGENT ADMISSION STATION TAS12P-AS1 TAS12-AS1 Installation Instructions Alvarado Manufacturing Company, Inc. 12660 Colony Street, Chino, CA 91710 Telephone: +1 (909) 591-8431 Fax: +1 (909) 628-1403 support@alvaradomfg.com www.alvaradomfg.com PUD3677R1-0...
  • Page 2: Table Of Contents

    This symbol is used in this manual to designate useful information for the installer and operator. NOTE Please read these instructions. For questions, please contact Alvarado at (909) 591-8431, Monday – Friday 6:30am to 4:30 PST. Please read this manual completely before installing or operating the purchased product. Page 2 For Assistance: support@alvaradomfg.com +1 (909) 591-8431...
  • Page 3: Introduction

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Introduction This manual provides installation and troubleshooting instructions for Alvarado's TAS12-AS1 & TAS12P-AS1 Intelligent Admission Stations. Operation and advanced configuration instructions are outside the scope of this manual. At the end of the installation section, instructions are provided for powering up the device and performing a basic functions check.
  • Page 4: Installation Tools

    It is the customer's responsibility to ensure that all conduit and corresponding lines are installed prior to installing the TAS12-AS1. The conduit stub-up location should be dead-center of the pedestal. The maximum hole size for conduit is 2 1/4". It is recommended that a licensed electrician perform these steps. The following lines must be run before installing the pedestal: •...
  • Page 5: Installation Instructions

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Installation Instructions Pedestal Installation Fig. 1 Pedestal Base Dimensions Slab Requirements • The slab must be a minimum of 4" thick. The pedestal may only be installed on concrete. • Do not install the pedestal on asphalt.
  • Page 6 TAS12-AS1 & TAS12P-AS1 Installation Instructions Pedestal Installation (cont.) Fig. 4 Inserting Anchor Bolts 6. Place the pedestal base back over the anchor holes and anchor it with four (4) ⅜" x 2½" anchor bolts and flat washers [Figure 4]. ⅜" x 2½"...
  • Page 7: Mounting The Tas12 Unit

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Mounting the TAS12 Unit Fig. 7 TAS12 Mounting Screws 1. Unlock and open the pedestal box lid [Figure 7]. 2. Using a 5/32" Allen wrench, loosen the four (4) TAS12 mounting screws that secure the stabilizer plates to the lid [Figure 7]. Do not completely remove the screws.
  • Page 8: Wiring Instructions

    TAS12-AS1 & TAS12P-AS1 Installation Instructions Mounting the TAS12 Unit (cont.) Fig. 9 Blackout Pad 7. Remove the plastic backing off the self-adhesive blackout pad. Center the blackout pad under TAS12 and press firmly into place [Figure 9]. Blackout (TAS12-AS1 shown)
  • Page 9: Tas12 Wiring

    TAS12-AS1 &TAS12P-AS1 Installation Instructions TAS12 Wiring TAS12 Inputs Fig. 11 A Power Input B USB Input C USB Input D Ethernet Input E Interface Input (See Below) NOTE USB inputs are interchangeable. Locate the following cables in the pedestal box. Use the instructions below to complete TAS12 wiring.
  • Page 10: Loading Printer Paper (Tas12P-As1)

    *Paper rolls up to 7" in diameter (roughly 885' of paper) may be used. Contact Zebra for information on custom paper roll stock. If you have questions regarding paper compatibility, contact Alvarado or Zebra Technical Support for assistance. 1. Power ON the TAS12P-AS1.
  • Page 11: Post-Installation Functions Check

    The following is assumed: • The facility's communication network and GateLink10 server are online and operational. • The TAS12-AS1's are configured with the appropriate network settings for the facility. • The Validation Service is running on the GateLink10 server. Power Button Fig.
  • Page 12: Perform Device Tests

    TAS12-AS1 & TAS12P-AS1 Installation Instructions Perform Device Tests Fig. 15 Login Screen Online NOTE Status Icon The use of a stylus is recommended for all touch screen operations. 1. Tap the TAS12 screen to bring up the Login Screen [Figure 15]. To confirm the TAS12 is connected to the network, verify the online status icon in the top-right corner is GREEN [Figure 15].
  • Page 13: Scan A Sample Barcoded Ticket

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Scan a Sample Barcoded Ticket Fig. 18 Scanning a Ticket 1. Scan a sample barcoded ticket. To scan, place the barcoded ticket on the blackout pad facing up and towards the unit [Figure 18]. The scanner will beep when the ticket has been scanned.
  • Page 14: Troubleshooting

    TAS12-AS1 & TAS12P-AS1 Installation Instructions Troubleshooting After performing a troubleshooting step, make sure to cycle the power to the TAS12-AS1. This re-initializes power to the components allowing the change to take effect. TAS12 Display Issue Possible Cause Solution The TAS12 display is black with...
  • Page 15 GateLink10 to resolve this issue. server or is on the wrong network. If this troubleshooting guide did not resolve your issue, contact Alvarado Technical Support for further assistance. Replacement parts can be obtained by contacting Alvarado Technical Support. PUD3677R1-0 For Assistance: support@alvaradomfg.com +1 (909) 591-8431...
  • Page 16 TAS12-AS1 & TAS12P-AS1 Installation Instructions Troubleshooting (cont.) Fig. 20 Pedestal Box Components (TAS12P-AS1 shown) Power Supply Fuse (3A slo blo) C Power Button D Primary Power Terminal Block Page 16 For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD3677R1-0...
  • Page 17 TAS12-AS1 &TAS12P-AS1 Installation Instructions Troubleshooting (cont.) Fig. 21 Fig. 22 TAS12 Electronics Assembly TAS12 Scanner Cable Backplane Assembly Scanner Cable Display Power Cable Display Assembly Fig. 24 TAS12 Touch Screen Board Fig. 23 TAS12 Display Ribbon Cable Lock Tab Display...
  • Page 18 TAS12-AS1 & TAS12P-AS1 Installation Instructions Troubleshooting (cont.) Fig. 25 TAS12 Backplane Board Fig. 24A Correct DIP SW2 Configuration Page 18 For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD3677R1-0...
  • Page 19: Appendix A - Plan, Elevation And Footprint Drawings

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Appendix A - Plan, Elevation and Footprint Drawings TAS12-AS1 50.1[1272] 39[991] 3[76] 1[24] 4.7[119] 5.6[142] 45° TYPICAL 4.4[111] 2.3[58] 12[305] 8X .6[16] 5.6[142] (ANCHORING HOLES) 7[178] PUD3677R1-0 For Assistance: support@alvaradomfg.com +1 (909) 591-8431 Page 19...
  • Page 20: Tas12P-As1

    TAS12-AS1 & TAS12P-AS1 Installation Instructions Appendix A - Plan, Elevation and Footprint Drawings (cont.) TAS12P-AS1 45° TYPICAL 4.4[111] 2.3[58] 16.1[409] 8X .6[16] 5.6[142] (ANCHORING HOLES) Page 20 For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD3677R1-0...
  • Page 21: Revision History

    TAS12-AS1 &TAS12P-AS1 Installation Instructions Revision History Revision Date Author Description 09/19/2014 A. Flores Original document PUD3677R1-0 For Assistance: support@alvaradomfg.com +1 (909) 591-8431 Page 21...
  • Page 22 © 2014 Alvarado Manufacturing Company, Inc. This work may not be reproduced, published or redistributed, in whole or in part, without the express prior written permission of Alvarado.

This manual is also suitable for:

Tas12p-as1

Table of Contents