HAP-P Lubricator
Manual, One Shot
General
Lubricator includes a spring return piston pump and is operated by pushing a lever which raises a
piston and compresses a spring, discharging oil into the system. Discharge volume and pressure are
independent of oil viscosity.
Operation
Lubricator includes a spring return piston pump in a plastic reservoir. Pulling up slowly on the lever
handle to the stop fills the cylinder with a predetermined volume of oil. Upon release, spring
pressure discharges the oil into the system and returns the handle to the original position.
Lubricator must be operated at intervals recommended by machine manufacturer.
Technical Data
Reservoir Capacity
Lubricator Inlet Filter
Discharge Pressure
Factory Discharge Setting
Piston Diameter
Piston Stroke Setting
Discharge Volume Per Stroke
Viscosity range
Outlet
Notes Regarding Use
1.
Lubricator inlet fi lter should be inspected periodically and cleaned/replaced as required. To
install replacement, disconnect discharge tubing and remove cylinder cap.
2.
Discharge pressure will decrease as discharge volume decreases and the number of meter
units in the system increases.
Piston Stroke Setting
Discharge Volume/Stroke (cc)
System & Limitations
Use meter units type F. Total system fl ow (ø) limitation is given in the table below.
Meter Units (#)
CC Per Shot
5.0
15
1750
20
1500
25
1230
30
950
40
780
50
640
60
570
70
500
1.
475cc (1 pint)
40 micron particle separation
60 psi average
15cc
1/18"
1/2 to 1-1/8"
5 to 15cc
100 to 10,000 SSU at operating temperature
1/8"NPTF
1-1/8"
13/16"
15
10
7.5
10
2400
2900
1700
2200
1500
1700
1200
1400
960
1100
820
920
710
810
600
720
21/32"
1/2"
7.5
5.0
15
3500
2600
2000
1700
1300
1100
960
860
BIJUR DELIMON INTERNATIONAL
TEL
(+44) 01432 365000
WWW.BIJURDELIMON.COM
WWW.BDICOOLING.COM
Denco Lubrication Ltd,
Ramsden Court, Ramsden Road,
Rotherwas Industrial Estate,
Hereford, Herefordshire, HR2 6LR
24375 • R3 04/13

Advertisement

loading
Need help?

Need help?

Do you have a question about the HAP-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bijur Delimon HAP-P

  • Page 1 HAP-P Lubricator Manual, One Shot General Lubricator includes a spring return piston pump and is operated by pushing a lever which raises a piston and compresses a spring, discharging oil into the system. Discharge volume and pressure are independent of oil viscosity.
  • Page 2 (fine screen), filter disc, filter clamp ring and filter snap ring. How to Order Name Part # Lubricator HAP-P D3221C When ordering, specify by name and part number, e.g. Lubricator HAP-P, Part #D3221C. Service Parts Before removing cylinder cap, pull up Item Description Part #...
  • Page 3 HAP-P Lubricator Manual, One Shot Dimensional Schematic Measurements shown in inches. BIJUR DELIMON INTERNATIONAL (+44) 01432 365000 WWW.BIJURDELIMON.COM WWW.BDICOOLING.COM Denco Lubrication Ltd, Ramsden Court, Ramsden Road, Rotherwas Industrial Estate, Hereford, Herefordshire, HR2 6LR 24375 • R3 04/13...

This manual is also suitable for:

D3221c