Note: There is an increased skid risk in case of spilled/leaked out lubricants. They are to be removed at once properly. Safety sign according to DIN 4844, warning about skid risk. BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
(Ordinance on Waste Recovery and Disposal lead to dangers, these parts have to be Records). protected against touch. Protection against touch for moving parts (e. g. coupling) must not be removed when the machine is in operation. BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
APPLICATION The WS-E gear wheel pump unit is primarily used in single-line systems with dynamic dividers of type ZE-E, and when connected in this way, the unit allows for the targeted and metered lubrication of moving lubrication points by means of a flying drop (up to 7 drops per second, depending on the viscosity).
Page 5
When the power supply to the solenoid valve is started, the valve is mechanically switched and the oil cycle is interrupted. The oil is delivered abruptly in the direction of the outlet, and if the unit is being used in the WS-E system, then the oil can serve the following ZE-E dividers.
Page 7
For a 12-litre tank, max. operating voltage 250V (art. no.: 391611113) Max. switching current .................. at 24V = 1A; at 120V = 0.5A; at 230V = 0.261A Max. switching capacity ................................60VA Switching outputs for ................................empty BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
TECHNICAL DATA Wiring diagram for terminal box 76922-7743 Connection dimensions: 113 mm x 52 mm Central drilled holes with bottom of housing BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
Terminal box (12-litre version only) - 04 Automotive system (PSA) with filling via sealing nipple for 4-litre version - 05 Automotive system (PSA) with filling via sealing nipple for 12-litre version - 06 Coding example results with accessories: WSE01A0224B03 WSE01A0123B04 WSE01A0223A05 WSE01A0124B06 BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
The ventilation process is described below. o Make sure that all connected pipelines are correctly fitted. o Fill the oil tank before commissioning the pump unit or lubrication system! BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
Page 11
Check whether the motor rotation direction is correct when the power supply is turned on. (Arrow on the motor) o The oil is circulated via the opened solenoid valve (in a de-pressurised state). Solenoid valve o Remove the plug on the solenoid valve in order to prevent pulsing during the adjustment phase. BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
Page 12
The disconnected plug must be re-connected to the solenoid valve. o A lubrication cycle must then be performed. This is performed by triggering impulses in quick succession on the proximity switch, either by damping the electronic field or by repeatedly breaking the light barrier. BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
Setting screw Screw plug WS-E pressure relief Remove the screw plug and use a standard screwdriver to turn the setting screw in a clockwise direction to increase the pressure. Turning the setting screw in an anti-clockwise direction reduces the pressure. Please note that the maximum permissible operating pressure is 30 bar.
Other than that, there are no other particular transport or storage regulations. SUITABLE SYSTEM COMPONENTS The following distributor types are primarily used in combination with the pump unit: ZE-E dividers (see ZE-E product documents). PLATES Company sign Type plate BIJUR DELIMON INTERNATIONAL BA_2018_1_GB_WSE...
Need help?
Do you have a question about the WS-E and is the answer not in the manual?
Questions and answers