16.10 Setting the clock and the day of the week

Press "M"; scroll with the wheel until the "clock" icon starts
flashing "
".
Then press "Confirm"
Scroll with the wheel to set the hour.
and scroll
Press "Confirm"
again to set the minutes.
and scroll
Press "Confirm"
to set the current date.
Fig. 67
AUTO
P
+
-
DAY
-
DAY
DAY
+
Use the TOUCH PAD to increase or
decrease the value.
_
Use the Confirm button to confirm and move
to the next setting.
Set the day of the week as follows:
day 1 = Monday, day 2 = Tuesday,
day 3 = Wednesday, ... ... day 7 = Sunday
.
+
+
-
Lindab reserves the right to make changes without prior notice

17. Supplementary functions

17.1 Booster mode

This is enabled by a remote control normally located in a
bathroom or kitchen.
The power board of the centralised unit receives the
pulse from the outside and enables the "Booster Mode"
In this case the "Boost" icon appears as a notification
on the screen of the unit's control panel.
Fig. 68
DAY
Like for "Party Mode", "Booster Mode" determines an
increase in the timed speed respect to the nominal speed.
The percentage of the duration and of the speed
increase of the ventilation unit can be configured by the
installer upon a specific request of the user.
The standard duration is 3 hours (default) and the
standard percentage is 130% beyond the nominal
speed.
Before standard duration ends, user can stop Booster
mode by repeating the command on the remote
switch.

17.2 Fireplace function

If the unit is interfaced with an negative pressure
ambient pressure switch and is set in the DIP-SWITCH
configuration recommended in presence of a natural
draught chimney, the unit is automatically turned off when
the ignition of the fireplace causes negative pressure in
the room.
This occurs in order to prevent the ambient pressure
induced by the action of the dual flow ventilation unit
from counteracting the natural draught of the fireplace
and releasing smoke into the room.

17.3 Boiler function

If the unit is interfaced with a remote switch and is set in
the DIP-SWITCH configuration recommended in presence
of an atmospheric boiler, the unit is forced into a strong
imbalance supply mode in order to facilitate the ignition
of the boiler.
The mode remains active as long as the switch stays in
the activation position.