Installation instructions

9.4 Condensate drain connection

The connection for the condensate drain is located
underneath the appliance:
Connect the condensate drain to the domestic sewage
system using a duct or pipe (siphoned).
Condensate must be drained from a minimum height of
100 mm.
PLEASE NOTE: if you choose the version with right
side connection, invert the condensate drain plug (see
paragraph "How to change connection").
Fig. 9
1 1/2 " G
Attention! Make sure that the siphon of the
condensate drain connected to the domestic
sewer system is always full of water.
Attention! Make sure that the end of the siphon
is at least 100 mm below the water level.
16
Y
Lindab reserves the right to make changes without prior notice
li n d a b | w e s i m p l i fy c o n s t r u c t ion

9.5 Floor installation of appliance

OPTIONAL ACCESSORY
As an alternative, the residential ventilation appliance can be
installed using the floor stands.
Fixing the stands
Fig. 10
4
1
2
M8 x 20
1. Fix the stands(1) using the screws (2) and
washers (3),supplied with the accessory, at the
bottom of the appliance (4). Fasten the crossbar
(5) to the support (1).
2. Lift the unit and position it vertically
3. Use a spirit level to check the position of the
appliance.
Fig. 11
2022-01-28
RHR-CF
5
3
13
4
1
2
M8 x 2