Regulus CSE2 MIX-BP F G75 1F Installation And Operation Manual

Regulus CSE2 MIX-BP F G75 1F Installation And Operation Manual

Pump station

Advertisement

Quick Links

www.regulus.eu
EN
Installation and Operation Manual
CSE2 MIX-BP F G75 1F PUMP STATION
CSE2 MIX-BP F G75 1F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSE2 MIX-BP F G75 1F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regulus CSE2 MIX-BP F G75 1F

  • Page 1 Installation and Operation Manual CSE2 MIX-BP F G75 1F PUMP STATION CSE2 MIX-BP F G75 1F...
  • Page 2: Table Of Contents

    3.4. FILTER WITH MAGNET ..............3.5. BALL VALVES ................EXAMPLES OF PUMP STATION CONNECTION ........PUMP STATION INSTALLATION ............. TEMPERATURE SENSOR INSTALLATION ..........OPTIONAL ACCESSORIES ..............APPENDIX – ACTUATOR ADJUSTMENT ..........Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 3: Introduction

    INTRODUCTION CSE2 MIX-BP F G75 1F twin-line pump station is designed for mixed heating circuits. It provides flow through the heating system, mixes to the outlet temperature. Since the mixing valve is not fitted with an actuator, any actuator may be used that will meet the needs of the particular system and control.
  • Page 4: Pump Station Components

    6 – Lever for ball valves 7 – Ball valve w. sheath for temperature sensor (heating circuit outlet) 8 – Ball valve w. sheath for temperature sensor (heating circuit inlet) 9 – Mixing valve, no actuator Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 5: Upm3 Flex As 25-75 130 Pump

    - without PWM signal the pump runs at the max. speed according to the selected curve Pump Performance Curves Curve Max. H Max. P (upper (lower graph) graph) 33 W 39 W 7.5 m 60 W Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 6 If you pass the desired setting, you have to go one more round until it appears again. ERROR DISPLAY DISPLAY ERROR Seized pump Too low power supply voltage Electric fault Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 7: Mixing Valve

    Dirt trapped on the magnet must be wiped off and then reassembled by inserting the strainer, screwing in and tightening the cap. Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 8: Ball Valves

    As a result, unintentional closure of the system by an unauthorized person is not possible. OPEN CLOSED groove in the flow direction groove perpendicular to the flow direction Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 9: Examples Of Pump Station Connection

    EXAMPLES OF PUMP STATION CONNECTION Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 10 Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 11: Pump Station Installation

    Permitted and prohibited positions of the pump station Permitted positions Conditionally permissible positions Prohibited positions (may be used when a filter is replaced by the filter replacement section, code 19017)     Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 12: Temperature Sensor Installation

    Temperature sensor placement Securing the temperature sensor with the screw Running the sensor cable through the recess in the insulation Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 13 Trimming the cable passage lock Installed sensors Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 14: Optional Accessories

    A – Filter replacement section for CSE2 Code 19017 Loosen the unions above and under Remove the filter and mount the filter the filter. replacement section (code 19017) in its place. Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 15 Union 1“ Fu/M incl. gasket Code 15695 Remove both the connecting fittings. Install the union 15695 in their place, then attach the ball valve w. drain valve (17415) to the union.. Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 16 (for flow line of CSE2 pump stations) Code 18797 Remove both the connecting fittings.. Install the extended union with check valve (18653) to the return line. Install the extended union (18797) to the flow line. Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 17 D – Union to connect CSE2 to 5/4” manifold - 1“x5/4“ Fu/F Code 17920 Remove both the connecting fittings. Replace them with the union 17920 intended for connection to a manifold. Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 18 Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 19 Regulus CSE2 MIX-BP F G75 1F - www.regulus.eu │...
  • Page 20 ©2022 We reserve the right to errors, changes and improvements without prior notice. REGULUS spol. s r.o. E-mail: sales@regulus.eu Web: www.regulus.eu...

This manual is also suitable for:

18082

Table of Contents