The information contained in this document is not subject to Export Control Regulation in Canada.
Using Outputs to drive other Calibir Inputs
A synchronization method where one Calibir camera signals other Calibir cameras.
Note: One Calibir output can drive a maximum of three Calibir inputs, as illustrated
below.
User IO
Power
(GPO_P0)
(GPO_CMD_PWR)
Camera (Slave 1)
Calibir GXM640 IR Camera User's Manual
Camera IO
Interface
Do not exceed more then three
!
10
9
slave cameras per GPO line.
8
7
6
5
4
3
2
1
Camera IO
Interface
10
9
8
7
(GPI_P0)
6
5
(GPI_CMD_GND)
4
3
2
1
User IO
Ground
GPI P0 can be used as input
!
trigger.
Camera (Slave 2)
Camera IO
Interface
10
9
8
7
(GPI_P0)
6
5
(GPI_CMD_GND)
4
3
2
1
User IO
Ground
Camera (Slave 3)
Camera IO
Interface
10
9
8
7
(GPI_P0)
6
5
(GPI_CMD_GND)
4
3
2
1
User IO
Ground
Technical Specifications 135