Dalsa Calibir GXM640 User Manual page 113

Table of Contents

Advertisement

The information contained in this document is not subject to Export Control Regulation in Canada.
Display Name
Greater Than
Criteria Threshold
Min Pixel Count
Alarm Status
Off
On
Reset All Alarms
Zone Selector
Zone 1
Zone 2
Zone X1
Zone Y1
Zone X2
Zone Y2
Counter Selector
Counter1
Counter Event Source
Line1
Counter Event
Activation
Rising Edge
Counter Reset
Counter Value
Counter Reset Value
Counter Status
Active
Acquisition Start
Acquisition End
Link Speed Change
Log (errors)
Calibir GXM640 IR Camera User's Manual
Feature & Values
GreaterThan
alarmCriteriaThreshold
alarmPixelCountThreshold
alarmStatus
alarmResetAll
zoneSelector
Zone1
Zone2
zoneX1
zoneY1
zoneX2
zoneY2
CounterSelector
Counter1
CounterEventSource
CounterEventActivation
RisingEdge
CounterReset
CounterValue
CounterValueAtReset
CounterStatus
Active
EventAcquisitionStart
EventAcquisitionEnd
EventLinkSpeedChange
EventlogError
Description
For Pixel Count-type alarms, a pixel will be
counted if its value is greater than the Criteria
Threshold. For other alarms, alarm will be
triggered if the Alarm Source Value is greater than
the Criteria Threshold.
Sets the threshold value for which an alarm is
triggered.
For Pixel Count-type alarms, this represents the
minimum number of pixels that must meet the
alarm criteria before the alarm is triggered.
Returns the status of the currently selected alarm.
Once triggered, alarm will remain active until it is
reset.
Off
Alarm is not active.
On
Alarm is active.
Resets all alarms.
Selects the Zone to configure.
Configure Zone 1.
Configure Zone 2.
X coordinate (horizontal, from left) of the top-left
corner of the selected Zone.
Y coordinate (vertical, from top) of the top-left
corner of the selected Zone.
X coordinate (horizontal, from left) of the bottom-
right corner of the selected Zone.
Y coordinate (vertical, from top) of the bottom-
right corner of the selected Zone.
Specifies the counter being accessed.
Selects Counter 1.
Selects the event source to increment the
counter.
Line1
Counts the number of transistions on Line 1 input.
Selects the activation mode for the event source
signal
Rising edge signal transition increases the
selected counter.
Performs a software reset of the selected counter
and starts it. The counter starts counting events
immediately after the reset.
Reads the current value of the selected counter.
Reads the value of the selected counter when it
was reset by a CounterReset command.
Returns the current status of the counter.
Counter is counting.
Represents the event ID to identify the
EventAcquisitionStart event.
Represents the event ID to identify the
EventAcquisitionEndt event.
Represents the event ID to identify the
EventLinkSpeedChange event.
Represents the event ID to identify the
EventlogError event.
Operational Reference  113
View
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
DFNC
Beginner
Beginner
Beginner
Expert
Beginner
Beginner
Beginner
Guru
Beginner
Guru
Guru

Advertisement

Table of Contents
loading

Table of Contents