External Output AC Timing Characteristics
The graphic below defines the test conditions used to measure the Calibir external output
AC characteristics, as detailed in the table that follows.
Output Common Power
Output
R
Load
Opto-coupled Output (Pin 6): AC Characteristics
Note: All measurements subject to some rounding.
Output
Output
Common
Current
Power
3V
16 mA
5V
16 mA
21 mA
12V
16 mA
24 mA
24V
16 mA
24 mA
132  Technical Specifications
Control
Signal
100%
90%
Output
10%
Output
Voltage
8 mA
1.55V
1.25V
8 mA
3.32V
3.1V
2.9V
8 mA
10.2V
10.0V
9.5V
8 mA
22.5V
21.65V
21.3V
Output Control Signal
t
d1
t
rise
t
t
µs)
d1 (
rise (
Leading Delay
Rise Time
1.5us
8.96us
2.1us
8.58us
1.6us
4.6us
1.7us
6.3us
1.8us
7.2us
1.9us
2.8us
2.0us
3.9us
1.9us
3.0us
2.2us
3.0us
2.2us
2.6us
2.2us
2.7us
Calibir GXM640 IR Camera User's Manual
t
t
t
d2
t
fall
t
µs)
µs)
d2 (
Trailing Delay
4.5us
8.3us
12.6us
10.0us
8.8us
15.9us
11.0us
9.7us
18.5us
12.8us
11.4us
t
µs)
fall (
Fall Time
10us
8.6us
10.7us
8.5us
7.8us
13.6us
9.9us
6.3us
13.6us
11.0us
8.1us