Display Name
Alarm 3
Event Notification
Off
On
Once
PTP Mode
Off
Automatic
PTP Accuracy
PTP Status
Initializing
Faulty
Disabled
Listening
Master
Passive
Slave
PTP Clock ID
PTP Master Clock ID
PTP Master Offset
110  Operational Reference
Feature & Values
Alarm3
EventNotification
ptpMode
Automatic
ptpClockAccuracy
ptpStatus
Initializing
Faulty
Disabled
Listening
Master
Passive
Slave
ptpClockId
ptpMasterClockId
ptpMasterOffsetNs
Description
Event sent on control channel when Alarm 3 is
triggered.
Enable Events for the event type selected by the
EventSelector feature.
Off
The selected event is disabled.
On
The selected event will generate a software event.
Once
The selected event is enabled once and will be
disabled after.
Specifies the PTP (IEEE-1588: Precision Time
Protocol) operating mode as implemented by the
Calibir.
Off
PTP is disabled on the device.
PTP is enabled on the device. The camera can
become a Master or Slave device. The Master
device is automatically determined as per IEEE-
1588.
Indicates the expected accuracy of the PTP
synchronization.
Specifies dynamically the current PTP state of the
device. (ref: IEEE Std 1588-2008)
The port initializes its data sets, hardware, and
communication facilities.
The fault state of the protocol.
The port shall not place any messages on its
communication path.
The port is waiting for the
announceReceiptTimeout to expire or to receive
an Announce message from a master. The
purpose of this state is to allow orderly addition of
clocks to a domain. A port in this state shall not
place any PTP messages on its communication
path except for Pdelay_Req, Pdelay_Resp,
Pdelay_Resp_Follow_Up, or signaling messages,
or management messages that are a required
response to another management message.
The port is behaving as a master port.
The port shall not place any messages on its
communication path except for Pdelay_Req,
Pdelay_Resp, Pdelay_Resp_Follow_Up, or
signaling messages, or management messages
that are a required response to another
management message.
The port is synchronizing to the selected master
port.
PTP port identity of the device, printed as
xxxxxxxxxxxxxxxx.yyyy, where x=clock ID and
y=port number (both in hexadecimal notation)
The clock ID is an Extended Unique Identifier
(EUI)-64 64-bit ID, converted from the 48-bit
MAC address, by inserting 0xfffe at the middle of
the MAC address and terminating with the port
number: yyyy.
PTP port identity of the current master, printed as
xxxxxxxxxxxxxxxx.yyyy, where x=clock ID and
y=port number (both in hexadecimal notation)
Dynamically returns the 64-bit value of the PTP
offset with the master. This value is the input for
clock corrections for the slave device clock servo
algorithms.
Calibir GXM640 IR Camera User's Manual
View
Expert
Beginner
DFNC
Expert
DFNC
Guru
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC