Case 3: Potential Uncertainty to the Start Time
Conditions:
initial TimestampReset resets Timestamp counter
timestampModulo = 10
at time=19, set timestampModuloStartTime =20
Case 3 differs only from case 2 by showing that there is a period of uncertainty if the
start time is too close to the first modulo count that follows. The first frame acquisition
may occur at the first modulo count time or at the following. The actual value for the
uncertainty period may vary with different camera and network conditions.
00
10
Uncertainty
Period
104  Operational Reference
20
30
F1
F1
F1?
40
50
F2
F3