CAMDEN CX-DE1200 Installation Instructions Manual

Delayed egress electro magnetic lock special locking arrangement
Hide thumbs Also See for CX-DE1200:

Advertisement

Quick Links

E l ec t r if i e d Lo ck s , R e l ay s a n d Time rs
CX-DE1200
Delayed Egress Electro Magnetic Lock
Special Locking Arrangement
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
1- CX-DE1200 Electro Magnetic Lock Housing
assemble with main controller PCB & Magnetic Plate
1- Mounting Template
4- Adhesive door signage
THIS PRODUCT MUST BE CONNECTED INTO A FIRE ALARM SYSTEM PER NFPA
CODE OR OTHER REGULATIONS SO THAT, IN THE EVENT OF FIRE, THE TIME
DELAY WILL BE BYPASSED. CONTACT YOUR LOCAL CODE AUTHORITY TO VERIFY
COMPLIANCE WITH FIRE AND BUILDING CODES. THE DELAYED EGRESS DEVICE
SHOULD BE ROUTINELY CHECKED FOR PROPER OPERATION AND COMPLIANCE
WITH FIRE AND BUILDING CODES.
1. DESCRIPTION
Intended for use in an Indoor location - Out Swing.
When an unauthorized exit is trigger, the delays exit through
the door for a period of 15 or 30 seconds. An LED bar segment
display countdown by seconds and voice messages to inform
the person planning to exit with the remaining times to unlock.
In the meantime, the person exiting must wait to allow time for
security personnel or staff to respond. The door will eventually
unlock after the 15 or 30 seconds delay time has passed,
permitting the exit. During an emergency, a signal from the
fire/life safety system will release the lock promptly.
2. SPECIFICATIONS
Voltage
Current Draw
Lock Output
Lock Status Relay
Rating Max. *
Alarm Output
Rating Max. *
DPS Rating Max. *
Bond Sensor Rating Max. *
ATS Rating Max. *
Operating Temperature
Operating Humidity
Dimensions
(Lock)
Dimensions
(Armature Plate)
Note: * Separately-energized
1- Installation Instructions & Wiring Diagrams
1- Armature Plate Assembled Housing
& Proxy Trigger
1- Electro Magnetic Lock Screw Packaging
12/24V DC +/- 10% (Auto Sensing)
Power Suplly must be UL 294 or
UL 603 Listed with a Class 2, power
limited output
600mA / 350mA
12/24 VDC, 1A
30 VDC, 2A, 1 pF
30 VDC, 2A, 1 pF
30 VDC, 0.1A, 1 pF
30 VDC, 2A, 1 pF
30 VAC / 42.4 VDC, 5A, 1 pF
0~55°C (32~131°F)
0~95% (non-condensing)
11" H x 3" W x 3" D
(280mm x 76mm x 74.5mm)
11" H x 2-5/8" W x 1" D
(280mm x 68mm x 23.5mm)
PUSH UNTIL ALARM SOUNDS.
DOOR CAN BE OPENED
IN 15 SECONDS.
KEEP PUSHING.
THIS DOOR WILL OPEN
IN 15 SECONDS.
ALARM WILL SOUND.
3. DIMENSIONS
UL 294 Access Control
Performance Levels:
Access Control Line Security
Destructive Attack
Endurance
Standby Power
Building & Fire Life Safety Code Compliant:
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1, UFC Uniform Fire Code
CBC California Building Code
BOCA National Building Code
Chicago Building Code
PUSH UNTIL ALARM SOUNDS.
DOOR CAN BE OPENED
IN 30 SECONDS.
KEEP PUSHING.
THIS DOOR WILL OPEN
IN 30 SECONDS.
ALARM WILL SOUND.
Levels:
Level I
Level I
Level IV
Level I
Page 1 of 9

Advertisement

Table of Contents
loading

Summary of Contents for CAMDEN CX-DE1200

  • Page 1 IBC International Building Code THIS PACKAGE INCLUDES: NFPA 101 Life Safety Code NFPA 1, UFC Uniform Fire Code 1- CX-DE1200 Electro Magnetic Lock Housing 1- Installation Instructions & Wiring Diagrams CBC California Building Code assemble with main controller PCB & Magnetic Plate...
  • Page 2: Dip Switch Settings

    CX-DE1200 Delayed Egress Electro Magnetic Lock INSTA L L AT I O N I NST RU CTI ONS 4. FEATURES • Holding Force up to 1200 Lbs. (Not validated by UL) • Vandal resistant Proximity Trigger Sensor • Field selectable exit delay time 15 or 30 seconds •...
  • Page 3: Display Mode

    CX-DE1200 Delayed Egress Electro Magnetic Lock INSTAL LATION INS T RUCT IONS Remove this J10 jumper only if Fire Panel or Smoke Detection system is connected to the (Fire P) terminal. 1 2 3 4 5 6 7 8 Fire P...
  • Page 4 CX-DE1200 Delayed Egress Electro Magnetic Lock INSTA L L AT I O N I NST RU CTI ONS 6. ARMATURE MOUNTING INSTRUCTIONS Step 1: Close the door, position the EM lock mounting location as close to the upper corner of the door with a minimum gap 1".
  • Page 5 CX-DE1200 Delayed Egress Electro Magnetic Lock INSTAL LATION INS T RUCT IONS Step 5: Slot in the electromagnet lock unit through the shoulder screw into the EZ mounting plate as shown in Figure 1-2 below. CAUTION: The lock unit must be held in place until secured with fixing screws.
  • Page 6 CX-DE1200 Delayed Egress Electro Magnetic Lock INSTA L L AT I O N I NST RU CTI ONS Step 8 After the lock unit has been mounted to the door and frame as per the provided template, route the wires through the access hole and out to the controller board.
  • Page 7 CX-DE1200 Delayed Egress Electro Magnetic Lock INSTAL LATION INS T RUCT IONS R-Exit Time: The Request Exit (R-Exit) time is field selectable for 1, 15, 20, or 30 seconds. The R-Exit time is the duration for the lock that will remain Unlocked (Bypass), after a remote normally open contact switch is momentarily activated.
  • Page 8: Parts Replacement

    CX-DE1200 Delayed Egress Electro Magnetic Lock INSTA L L AT I O N I NST RU CTI ONS 7. CONFIGURATION Delay Nuisance Trigger Power-Up Door Prop Anti-Pass Reset After Request to Exit Period Configuration Release Delay Type State Open Back...
  • Page 9: Accessories Wiring

    WARNING: Improper installation, maintenance, inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock, armature plate and associated hardware to disengage and fall, causing serious bodily injury and property damage. Camden will not be liable to the installer, purchaser, end user or anyone else for damage or injury to person or property due to improper installation, care, storage, handling, maintenance, inspection, abuse, misuse or act of God or nature involving this product or any related accessories or parts.

Table of Contents