Display Mode; Jumper Settings - CAMDEN CX-DE1200 Installation Instructions Manual

Delayed egress electro magnetic lock special locking arrangement
Hide thumbs Also See for CX-DE1200:
Table of Contents

Advertisement

Remove this J10 jumper only if Fire Panel or Smoke Detection system is connected to the (Fire P) terminal.
Built-In
Key Switch
(Reset &
(Manual Reset
NOTE:
Bypass)
Or Bypass)
1) all field-wiring to the unit
External Speaker
shall not exceed 30 m (98.5 ft)
8Ω, 1.5W (Optional)
in length.
2) all external power sources
shall be UL Listed with Class 2,
power-limited output.

Display Mode

Mode: 15 and 30 Seconds
Door armed and locked in 15 or 30 seconds mode
Mode: Bypass
Door unlocked (Either Bypass or R-exit)
Mode: Bypass
Door unlocked & alarm sounding until reset

Jumper Settings

Installed: Factory default setting
Uninstalled: Only if a dry contact (NC) from a
Pwr
Pwr
Fire P
Ex-Spkr
C NC
Lock Output not
to be used for
model CX-DE1200
Single Door Configuration
Optional direct passthrough
for CX-DE1201 tandem lock
Push Bar (Optional)
Jumper J10 (Fire Panel Input)
fire alarm panel or smoke
detector system is connected to
the "Fire P" terminals.
CX-DE1200 Delayed Egress Electro Magnetic Lock
Lock
Grn Rly
Red Rly
Ex-Trig
Reset
R-Exit Bypass
NO C NC
NO C NC
NO C NO C NO C NO C
CM-120i Keypad
(optional)
CM-1200
Key Switch
(Optional)
AC Main
3 Core Cable
Push Bar (Ex-Trig)
INSTAL LATION INS T RUCT IONS
ON
DIP
1 2 3 4 5 6 7 8
J10
DPS
Bond-S
ATS
NO C NC NO C NC
NO C NC
NO
AUX Rly
COM
NO
Main Rly
COM
GND
+12V
NO
COM
Fire Panel
2 Core Cable
Power Supply
Keypad
Key Switch