Dip Switch Settings - CAMDEN CX-DE1200 Installation Instructions Manual

Delayed egress electro magnetic lock special locking arrangement
Hide thumbs Also See for CX-DE1200:
Table of Contents

Advertisement

CX-DE1200 Delayed Egress Electro Magnetic Lock
INSTA L L AT I O N I NST RU CTI ONS
4. FEATURES
• Holding Force up to 1200 Lbs. (Not validated by UL)
• Field selectable exit delay time 15 or 30 seconds
• Nuisance Delay period either 1, 2 or 3 seconds
• 75dB Buzzing Tone with LED segment bar display time
seconds & field selectable voice alerts
• Choice of sensor to be activated:
- Door Motion
- Door Exit Device with momentary normally open contact
- Push Bar with momentary normally open contact
• Auto Start Up:
- Occurs when power supply is restored and/or the fire panel is
restored (When allowed by Building & Fire Life Safety Code)
• Manual Start Up:
- This is a California & UBC Building Code Compliant Feature.
Only after power supply restoration and fire panel reset
may the lock be Reset manual at the opening. This lock can
be reset with the built-in reset key switch or an external key
switch or a reset switch connected to the door
5. INSTALLATION CONCEPT AND ACCESSORIES
Seven configuration versions are available to be compliant to regional jurisdictions.
Delay Release Time
Models
Fixed
CX-DE1200
CX-DE1200-N2
15
CX-DE1200-N3
30
CX-DE1200-N4
15
CX-DE1200-B1
15
CX-DE1200-B2
30
CX-DE1200-B3
15
BOCA Compliance
Manual Reset: Is achieved by authorized personnel closing the door after an alarm and actuating the integral reset key switch
or by momentarily closing a contact connected to the remote RESET terminal.
Automatic Reset: Reset will automatically be initiated once the door has been opened, then closed and remains closed for
30 consecutive seconds.

Dip Switch Settings

Release Time
Nuisance Time
R-Exit Time
Trigger type
Start-Up State
Door POS Alarm
Anti Pass Back
Page 2 of 9
Nuisance Delay
(Seconds)
Selectable
Fixed
15 or 30
0
N# = NFPA Compliance
Warning Type
Languages
Voice Type
• Vandal resistant Proximity Trigger Sensor
• Auto Sensing Voltage Power Input 12/24 VDC
• Reverse power protection:
If someone hooks power up backwards, the board simply
does not turn on, protecting it from damage
• Optional Connection for Auxiliary Lock, CX-DE1201 (Double
Leaf Door)
• Hall Effect Sensor Monitoring Output
• Tamper Switch Output
• Tailgating Prevention - door will re-lock as soon as it closes
• Anti-Pass Back / Auto re-lock:
If door doesn't open after the count down, the door will
automatically re-lock.
Reset After Alarm
(Seconds)
Selectable
Selectable
1 or 2
0 or 1
0 or 1
0 or 1
0 or 3
Auto / Manual
0 or 3
Auto / Manual
Auto / Manual
B# = BOCA Compliance
WARNING!
!
Contact authority having jurisdiction for approval prior to
selecting release time, nuisance time and start-up settings.
Lock Status on Power-Up
Fixed
Fixed
Selectable
Locked / Unlocked
Manual
Locked / Unlocked
Manual
Locked / Unlocked
Manual
Manual
Unlocked
Locked / Unlocked
Locked / Unlocked
Locked / Unlocked