CAMDEN CX-ED1259-L Installation Instructions

Rim electric strike

Advertisement

This Package Includes:
1- 4 PIN power connector
1- 3 PIN door status
connector
4- Wire nuts
2- M5 x self tapping screws
4- M6 x 30 screws

1. Description

Camden CX-ED1259-L Grade 1 RIM strike for pullman
latches offer the very best strike quality and performance.
The strike design delivers unparalleled application flexibility,
with field selectable voltage, fail safe/fail secure operation
and mechanical adjustment of the strike body.

2. Specifications

Voltage
12/24V AC/DC
280mA@12V DC
Current Draw
140mA@24V DC
Static Strength
1,500 Lbs.
Dynamic Strength
70 Ft-Lbs.
1,000,000 Cycles (Factory Tested)
Endurance
250,000 Cycles (UL Verified)
UL 10C/CAN4-S104
Fire Rating
3 hrs. (Fail Secure Only)
Field Selectable
Mode
Fail Safe/Fail Secure
Mech. Adjustment
Strike Body/Faceplate
AC-Buzz
Operation
DC-Silent
Duty
Continuous
Latch Bolt Monitor
SPDT, 100mA @ 24V DC
Dimensions (Body)
9" H x 1 3/4" W x 1/2" D
(230mm x 45mm x 12.7mm)
2- M5 x 25 screws
spacers
4- M2.5 x 4 screws
1- MOV
1- Cover plate
Page 1 of 3
'RIM' Electric Strike

Installation Instructions

3. Dimensions

1
2 " [12.7 mm]
CX-ED1259-L
UL10C/
UL 1034
CAN4-S104,
Burglary
3hr. Fire rating
1 3 4 " [45.0 mm]
9" [230.0 mm]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CX-ED1259-L and is the answer not in the manual?

Questions and answers

Summary of Contents for CAMDEN CX-ED1259-L

  • Page 1: Installation Instructions

    1- Cover plate 4- M6 x 30 screws 1. Description Camden CX-ED1259-L Grade 1 RIM strike for pullman latches offer the very best strike quality and performance. The strike design delivers unparalleled application flexibility, with field selectable voltage, fail safe/fail secure operation and mechanical adjustment of the strike body.
  • Page 2 CX-ED1259-L ‘RIM’ Electric Strike 4. Installation 1a. Close door, then mark horizontal center line of Push 4a. Remove strike, and drill threads at screws position. bar keeper. 4b. Connect wires as per drawing. 2a. Using center line, measure (101.5mm) top and bottom, 4c.
  • Page 3 CX-ED1259-L ‘RIM’ Electric Strike 5. Connections 7. Setting Fail-Secure/Fail Safe POWER How to modify fail-safe to fail-secure or vice versa. 24V AC/DC 12V AC/DC 1. Loosen the screw at the back of the Electric strike as per Red: +24V Red/Black: +12V the diagram below.

Table of Contents