R-Exit Time:
The Request Exit (R-Exit) time is field selectable for 1, 15, 20, or 30 seconds. The R-Exit time is the duration for the lock that will
remain Unlocked (Bypass), after a remote normally open contact switch is momentarily activated. When activated with an access
control system, the R-Exit time cycle will start after the access control relay open time expires. The door will automatically re-lock if
the door is opened, then closed during the R-Exit time cycle.
Trigger Type:
The trigger type is field selectable either EXTERNAL or INTERNAL. Selecting INTERNAL mode uses the built-in proxy sensor and EX-
TRIG terminal to trigger the Release Time cycle. Selecting External mode will disable the INTERNAL mode sensor; activation of the
Release Time cycle is triggered by an external egress device equipped with a normally open contact switch.
Start-Up State:
The Start-Up selection, imply the state of lock during restoration of power up. It is field selectable either be LOCKED or UNLOCKED.
In the LOCKED mode, the lock will be reset to secure mode. In the UNLOCKED mode, the lock will remain unlocked and the LED Bar
display will indicate as per By-Pass mode. To reset the lock; a momentarily normally open contact to the RESET signal will re-lock the
door. This feature selection is to comply with building code requirements in jurisdictions that require manual reset or re-lock upon
loss and restoration of system power supply.
Warning Type:
The warning type is field selectable either TONE or VOICE. In secure status, the LED Bar displays a 15 segment or 30 segment LED
light. Each segment represents. Upon activation of the irreversible Release Time cycle, the LED Bar segment display begins to turn
off one by one. In VOICE mode, the countdown will be counted along with verbal exit guidance. When the LED bar display reaches
zero, the lock will release. The verbal voice guidance changes to a continuous verbal instruction announcing, "Door Unlocked". In
TONE ONLY mode, the countdown will be accompanied with a beeping tone only, and a continuous tone is heard once the Release
time cycle ends.
Languages:
The voice message can be in 3 languages which are field selectable. The languages are English (Default), French and Spanish.
Voice Type:
For English only, the voice type is field selectable for either a male or female voice.
Examples:
- 15 seconds Mode: "Door will unlock in 15 seconds; Door will unlock in 5 seconds; Door unlocked..."
(Both messages repeat "Door unlocked" until the lock is reset).
- 30 seconds Mode: "Door will unlock in 30 seconds; Door will unlock in 20 seconds; Door will unlock in 10 seconds;
Door will unlock in 5 seconds; Door unlocked..."
Door POS Alarm (DPA):
- DPA Active: The lock will enter alarm mode when the door is held open past the R-Exit time period triggering a buzzing tone or
alarm voice and the DPA can be Reset by the built-in key switch or remote reset.
- DPA Inactive: The lock will enter stand-by mode which will remain unlocked if the door is held open past the R-Exit time set.
No warning sound is emitted. The Lock can re-lock upon closure of the door.
Anti-Pass Back
If door doesn't open after the count down, the door will re-lock after a set time frame: 1 or 5 seconds.
Dip Switch Position
Release Time
ON : 30 seconds
OFF : 15 seconds
Nuisance Time
ON : 2 seconds
OFF : 1 second
R-Exit Time
ON - ON
: 1s
ON - OFF : 20s
OFF - OFF : 15s
OFF - ON : 30s
(Both messages repeat "Door unlocked" until the lock is reset).
ON
ON
DIP
1 2 3 4 5 6 7 8
OFF
Anti Pass Back
ON : 1s
OFF : 5s
Door POS Alarm (DPA)
ON : Alarm Mode
OFF : Standby Mode
Start-up State
ON : Locked
OFF : Unlocked
Trigger Type
ON : External
OFF : Internal
CX-DE1200 Delayed Egress Electro Magnetic Lock
INSTAL LATION INS T RUCT IONS
ON
DIP
1 2 3 4
Warning Type
ON : Voice
OFF : Tone
Languages
ON - ON : French
OFF - OFF : English
OFF - ON : Spanish
ON - OFF : French (Standby)
ON
OFF
Voice Type
ON : Male
OFF : Female
Note:
Only English version
has a Female Voice.