CAMDEN CX-ED1259L Installation Instructions Manual

Advertisement

Quick Links

E l ec t r if i e d Lo ck s , R e l ay s a n d Time rs
CX-ED1259L
'RIM' Electric Strike
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
(1) 4-PIN power connector
(1) 3-PIN door status
connector
(2) M5 self tapping screws
1. DESCRIPTION
Camden CX-ED1259-L Grade 1 RIM strike for pullman latches
offers the very best strike quality and performance. The strike
design delivers unparalleled application flexibility, with field
selectable voltage, fail safe/fail secure operation and mechanical
adjustment of the strike body.
2. SPECIFICATIONS
Voltage
Current Draw
Static Strength
Dynamic Strength
Endurance
Latch Protection
Fire Rating
Mode
Mech. Adjustment
Operation
Duty
Latch Bolt Monitor
Dimensions (Body)
(4) 14-20 x 1 1/2" screws
(2) 10-32 x 1" screw spacers
(4) 4-40 x 1/4" screws
(1) MOV
12/24V AC/DC
280mA@12V DC
140mA@24V DC
1,500 Lbs.
70 Ft-Lbs.
1,000,000 Cycles (Factory Tested)
250,000 Cycles (UL Verified)
1/2" - 3/4"
UL 10C/CAN4-S104
3 hrs. (Fail Secure Only)
Field Selectable
Fail Safe/Fail Secure
Strike Body
AC-Buzz, DC-Silent
Continuous
SPDT, 100mA @ 24V DC
9" H x 1 3/4" W x 1/2" D
(230mm x 45mm x 12.7mm)
(2) 1/8" S/S Spacers Plates
(1) Cover plate
(1) Install Jig
3. DIMENSIONS
1/2"
(12.7 mm)
UL 1034
UL 294
UL10C/
CAN4-S104,
3hr. Fire rating
1 3/4"
(45 mm)
9"
(230 mm)
Page 1 of 8

Advertisement

loading

Summary of Contents for CAMDEN CX-ED1259L

  • Page 1 (1) Install Jig (2) M5 self tapping screws (1) MOV 1. DESCRIPTION 3. DIMENSIONS Camden CX-ED1259-L Grade 1 RIM strike for pullman latches 1 3/4” 1/2” offers the very best strike quality and performance. The strike (45 mm) (12.7 mm)
  • Page 2: Installation

    - CX-ED1259L is the only ½” thick UL Fire listed RIM strike on considerations and a different installation technique. In addition, the market. This means that spacer plates (supplied with the Camden’s CX-ED1259L RIM strike is unique from competitive...
  • Page 3 CX-ED1259L ‘RIM’ Electric Strike INSTAL L AT ION INS T RUCT IONS Note: 1. Open door slightly, and remove the template. Jamb Hole punch Holes for self- tapping screws Hole punch Ø Jamb Connecting wire hole Note: 1. Use a Hole punch on marked positions 2.
  • Page 4 CX-ED1259L ‘RIM’ Electric Strike INSTA L L AT I O N I NST RU CTI ONS Step 2: Aligning the Strike 4. While adjusting strike, allow a small gap between strike 1. Using center line, measure 4 3/16” top and bottom, and body and crash bar (approx.
  • Page 5 CX-ED1259L ‘RIM’ Electric Strike INSTAL L AT ION INS T RUCT IONS Top View Jamb Latch Allow a small gap between strike body and crash bar. (Approx. Closed Door Crash Bar Spacer (install as needed) 10-32 x 1 (2pcs) 1/4-20 x 1...
  • Page 6 CX-ED1259L ‘RIM’ Electric Strike INSTA L L AT I O N I NST RU CTI ONS Step 3: Wiring the Strike Door Status Sensor White = N/O Orange = COM (Closed position) Grey = N/C FOR CUT WIRES GREY WHITE...
  • Page 7: Troubleshooting

    Step 2 – Confirm Door Alignment latch (as shown here) If the exit device has a deadlocking Virtually all of Camden’s electric strike models, including the latch, the CX-ED1259L RIM strike CX-ED1259L RIM strike, offer horizontal adjustment, to must be mounted so that the...
  • Page 8 CX-ED1259L ‘RIM’ Electric Strike INSTAL L AT ION INS T RUCT IONS Summary Consideration of the free movement of the exit device Adherence with the recommendations of this guide will avoid the latch and the keeper (jaws) most common problems associated with the installation of RIM of the RIM strike.