Technical data
6.3

Interface classification

According to the 24 V
as a data sink (sink) for interface types C and D and activated by data sources (sources) of the same
interface types.
The values contained in the table apply to the PMC SR6 used as a sink for interface types C and D
Class
Test pulse duration t
Test pulse interval T
Input resistance R
Input capacitance C
Input inductance L
PMC SR6 – Specific figures for the interface type C
Class
Test pulse duration t
Test pulse interval T
Input resistance R
Input current I
in ON state
Input current I
in OFF state
Input capacitance C
Input inductance L
PMC SR6 – Specific figures for the interface type D
1
See ZVEI, p. 16 and p. 19ff.
Manual PMC SR6 safety module
1005344-en-US-01
Intern
interface classification from ZVEI, the PMC SR6 safety module can be used
DC
Min.
i
10 ms
i
300 Ω
1
1
1
Min.
i
10 ms
i
150 Ω
1
1on
1off
1
1
Typ.
Max.
1
1000 µs
1.5 nF
10 µH
Typ.
Max.
1
1000 µs
60 mA
1 mA
3 nF
5 µH